NH Photovoltaic Fuse Links for Solar Panel Applications
32 to 200A, 1000Vdc PV Series
Description:
A range of NH size fuse links specifically
designed for protecting and isolating
photovoltaic array combiners and disconnects.
These fuse links are capable of interrupting low
overcurrents associated with faulted PV
systems (reverse current, multi-array fault).
MOQ: 3
Packaging 100% recyclable
Packaging:
Catalogue Symbol:
Class of Operation:
Fuse Size:
Fuse Holders:
Microswitches:
PV-(amp rating)ANH(size)
gPV and UL PV fuse links
NH Size 1
SD1-D-PV (Single-pole)
170H0236 or 170H0238
BVL50
IEC 60269-6, UL 2579
(File number E335324), CSA Listed,
RoHS compliant
Pending: CCC
Technical Data:
Rated Voltage:
Amps:
Rated Breaking Capacity:
Time Constant:
1000Vdc
32 - 200A
50kA
1-3ms
Standards/Approvals:
Dimensions - mm
Size 1
0$;
5(9
$
'(6&5,37,21
25,*,1$/ ,668( '5$:1 ,1 62/,':25.6
0$;
,1',&$725
,1',&$725
0$;
0$7(5,$/
81/(66 27+(5:,6( 63(&,),(' $// ',0(16,216
$5( ,1 0,//,0(7(56
19-06-2013
BU-SB10063
Form Solar NH
Page 1 of 3
Data Sheet 720133
™
NH Photovoltaic Fuse Links for Solar Panel Applications
32 to 200A, 1000Vdc PV Series
Technical Data
Part Number
PV-32ANH1
PV-40ANH1
PV-50ANH1
PV-63ANH1
PV-80ANH1
PV-100ANH1
PV-125ANH1
PV-160ANH1
PV-200ANH1
Current
Rating
(Amps)
32
40
50
63
80
100
125
160
200
Energy Integrals I
2
t (A
2
s)
Pre-Arcing
80
185
400
470
640
1300
2600
5200
10,200
Total at
1000V
720
1670
3600
4300
5760
11,700
23,400
46,800
82,000
Watts Loss
0.8 I
n
4.3
4.6
5.4
6.1
7.9
8.4
8.9
12.2
13
I
n
8.5
9
10.5
12
15.5
16.5
17.5
24
25
Time-Curent Characteristics
10000
200A (provisional data)
160A
1000
125A
100A
80A
63A
100
50A
40A
32A
Time in Seconds (s)
Pre-arcing Time (s)
10
1
0.1
0.01
10
100
1000
10000
Available Current, DC-Time Constant
(A)
Prospective current
1-3ms (Amps)
19-06-2013
BU-SB10063
Form Solar NH
Page 2 of 3
Data Sheet 720133
™
NH Photovoltaic Fuse Links for Solar Panel Applications
32 to 200A, 1000Vdc PV Series
Temperature Derating
100
90
80
Percentage of Rated Current
70
60
50
40
30
20
10
0
20
30
40
50
Ambient Temperature (
o
C)
60
70
80
The only controlled copy of this Data Sheet is the electronic read-only version located on the Cooper Bussmann Network Drive. All other copies of this document are by definition
uncontrolled. This bulletin is intended to clearly present comprehensive product data and provide technical information that will help the end user with design applications. Cooper Bussmann
reserves the right, without notice, to change design or construction of any products and to discontinue or limit distribution of any products. Cooper Bussmann also reserves the right to
change or update, without notice, any technical information contained in this bulletin. Once a product has been selected, it should be tested by the user in all possible applications.
19-06-2013
BU-SB10063
Form Solar NH
Page 3 of 3
Data Sheet 720133