MKW3000 Series
Model Selection Guide
Model
Number
Input
Voltage
Output
Voltage
Output Current
Input Current
Reflected
Ripple
Current
mA (Typ.)
Over
Voltage
Protection
VDC
3.9
6.8
15
18
{15
{18
3.9
6.8
15
18
{15
{18
3.9
6.8
15
18
{15
{18
Efficiency
VDC
MKW3021
MKW3022
MKW3023
MKW3024
MKW3026
MKW3027
MKW3031
MKW3032
MKW3033
MKW3034
MKW3036
MKW3037
MKW3041
MKW3042
MKW3043
MKW3044
MKW3046
MKW3047
12
( 9 ~ 18 )
24
( 18 ~ 36 )
48
( 36 ~ 75 )
VDC
3.3
5
12
15
{12
{15
3.3
5
12
15
{12
{15
3.3
5
12
15
{12
{15
Max.
mA
4000
4000
1670
1340
{835
{670
4000
4000
1670
1340
{835
{670
4000
4000
1670
1340
{835
{670
Min.
mA
240
240
100
80
{50
{40
240
240
100
80
{50
{40
240
240
100
80
{50
{40
@Max. Load @No Load
mA (Typ.)
mA (Typ.)
1358
1984
1898
30
1903
1898
1903
671
980
938
17
941
938
941
335
490
469
10
471
469
471
50
30
20
@Max. Load
% (Typ.)
81
84
88
88
88
88
82
85
89
89
89
89
82
85
89
89
89
89
Capacitive Load
Models by Vout
Maximum Capacitive Load
# For each output
3.3V
6800
5V
6800
12V
680
15V
680
{12V
#
270
{15V
#
270
Unit
uF
Input Fuse Selection Guide
12V Input Models
4000mA Slow - Blow Type
24V Input Models
2000mA Slow - Blow Type
48V Input Models
1000mA Slow - Blow Type
Input Specifications
Parameter
Start Voltage
Model
12V Input Models
24V Input Models
48V Input Models
Under Voltage Shutdown
12V Input Models
24V Input Models
48V Input Models
Reverse Polarity Input Current
Short Circuit Input Power
Input Filter
All Models
Min.
8.6
17
34
8.1
16
32
---
---
Typ.
8.8
17.5
35
8.3
16.5
33
---
---
Pi Filter
Max.
9
18
36
8.5
17
34
2
3500
A
mW
VDC
Unit
Total Power International, Inc.
Toll Free 877-646-0900(US)
www.total-power.com
MKW3000 Series
Output Specifications
Parameter
Output Voltage Accuracy
Output Voltage Balance
Line Regulation
Load Regulation (3.3Vout)
Load Regulation
Ripple & Noise (20MHz)
Ripple & Noise (20MHz)
Ripple & Noise (20MHz)
Over Power Protection
Transient Recovery Time
Transient Response Deviation
Temperature Coefficient
Output Short Circuit
25% Load Step Change
Over Line, Load & Temp.
Dual Output, Balanced Loads
Vin=Min. to Max.
Io=10% to 100%
Io=10% to 100%
Conditions
Min.
---
---
---
---
---
---
---
---
110
---
---
---
Continuous
Typ.
{0.5
{0.5
{0.1
{0.5
{0.1
55
---
---
---
150
{2
{0.01
Max.
{1.0
{2.0
{0.3
{1.0
{0.5
80
100
10
160
300
{4
{0.02
Unit
%
%
%
%
%
mV P-P
mV P-P
mV rms
%
uS
%
%/]
General Specifications
Parameter
Isolation Voltage Rated
Isolation Voltage Test
Isolation Resistance
Isolation Capacitance
Switching Frequency
MTBF
MIL-HDBK-217F @ 25], Ground Benign
Conditions
60 Seconds
Flash Tested for 1 Second
500VDC
100KHz,1V
Min.
1500
1650
1000
---
290
800
Typ.
---
---
---
1200
330
---
Max.
---
---
---
1500
360
---
Unit
VDC
VDC
M[
pF
KHz
K Hours
Remote On/Off Control
Parameter
Supply On
Supply Off
Standby Input Current
Control Input Current ( on )
Control Input Current ( off )
Control Common
Vin-RC = 5.0V
Vin-RC = 0V
Conditions
Min.
0
---
---
---
Typ.
---
2
---
---
Max.
1
5
5
-100
Unit
VDC
mA
uA
uA
2.5 to 100VDC or Open Circuit
Referenced to Negative Input
Notes :
1. Specifications typical at Ta=+25], resistive load, nominal input voltage, rated output current unless otherwise noted.
2. Transient recovery time is measured to within 1% error band for a step change in output load of 75% to 100%.
3. Ripple & Noise measurement bandwidth is 0-20 MHz.
4. These power converters require a minimum output loading to maintain specified regulation.
5. Operation under no-load conditions will not damage these modules; however, they may not meet all specifications listed.
6. All DC/DC converters should be externally fused at the front end for protection.
7. Other input and output voltage may be available, please contact factory.
8. To order the converter without Remote On/Off function, please add a suffix -N (e.g.MKW3021-N).
9. To order the converter with heatsink, please add a suffix H (e.g. MKW3021H).
10. Specifications subject to change without notice.
Total Power International, Inc.
Toll Free 877-646-0900(US)
www.total-power.com
MKW3000 Series
100
90
Efficiency (%)
80
70
60
50
100
90
Efficiency (%)
Low
Nom
Input Voltage (V)
High
80
70
60
50
Low
Nom
Input Voltage (V)
High
Efficiency vs Input Voltage ( Single Output )
Efficiency vs Input Voltage ( Dual Output )
90
80
Efficiency (%)
90
80
Efficiency (%)
10
20
40
60
80
100
70
60
50
40
30
20
70
60
50
40
30
20
10
20
40
60
80
100
Load Current (%)
Load Current (%)
Efficiency vs Output Load ( Single Output )
Efficiency vs Output Load ( Dual Output )
100
80
Output Power (%)
Natural
convection
60
100LFM
200LFM
400LFM
100
400LFM
80
Output Power (%)
Natural
convection
200LFM
100LFM
60
40
40
20
0
-40
20
0
50
60
70
80
]
90
100
110
½
~
-40
50
60
70
80
]
90
100
110
Ambient Temperature
Ambient Temperature
Derating Curve without Heatsink
Derating Curve with Heatsink
Total Power International, Inc.
Toll Free 877-646-0900(US)
www.total-power.com