MIW3100 Series
5-6W, Wide Input Range DIP, Single & Dual Output DC/DC Converters
Key Features
Efficiency up to 86%
1500VDC Isolation
MTBF > 1,000,000 Hours
2:1 Wide Input Range
CSA1950 Safety Approval
Low Cost
Temperature Performance -40] to +71]
Short Circuit Protection
Industry Standard Pinout
UL 94V-0 Package Material
Internal SMD Construction
Minmax's MIW3100-Series Power modules are low-profile dc-dc
converters that operate over input voltage ranges of 9-18VDC and
18-36VDC which provide precisely regulated output voltages of 3.3V,
5V, 12V, {12V and {15VDC.
The -40] to +71] operating temperature range makes it ideal
for data communication equipments, mobile battery driven equipments,
distributed power systems, telecommunication equipments, mixed
analog/digital subsystems, process/machine control equipments,
computer peripheral systems and industrial robot systems.
The modules have a maximum powerrating of 6W and a typical
full-load efficiency of 86%, continuous short circuit, 50mA output
ripple, built-in filtering for both input and output minimize design-in
time, cost and eliminate the need for external filtering.
I/O Isolation
High
Power
Density
More Power
1500
VDC
$
Low Cost
2:1
Wide Range
Block Diagram
Single Output
Dual Output
+Vin
LC
Filter
+Vo
+Vin
LC
Filter
+Vo
Com.
-Vo
PFM
Isolation
Ref.Amp
PFM
Isolation
Ref.Amp
-Vo
-Vin
-Vin
1
MINMAX
REV:0 2005/04
MIW3100 Series
Model Selection Guide
Model
Number
Input
Voltage
VDC
MIW3121
MIW3122
MIW3123
MIW3126
MIW3127
MIW3131
MIW3132
MIW3133
MIW3136
MIW3137
24
( 18 ~ 36 )
12
( 9 ~ 18 )
Output
Voltage
VDC
3.3
5
12
{12
{15
3.3
5
12
{12
{15
Output Current
Max.
mA
1200
1000
500
{250
{200
1200
1000
500
{250
{200
Min.
mA
60
50
25
{12.5
{10
60
50
25
{12.5
{10
Input Current
@Max. Load
mA (Typ.)
429
514
595
595
595
209
251
291
291
291
5
15
20
25
@No Load
mA (Typ.)
Reflected
Ripple
Current
mA(Typ.)
Efficiency
@Max. Load
% (Typ.)
77
81
84
84
84
79
83
86
86
86
Absolute Maximum Ratings
Parameter
12VDC Input Models
Input Surge Voltage
( 1000 mS )
24VDC Input Models
Lead Temperature (1.5mm from case for 10 Sec.)
Internal Power Dissipation
Min.
-0.7
-0.7
---
---
Max.
25
50
260
2,500
Unit
VDC
VDC
]
mW
Notes :
1. Specifications typical at Ta=+25] resistive load,
nominal input voltage, rated output current unless
otherwise noted.
2. Transient recovery time is measured to within 1%
error band for a step change in output load of 75%
to 100%.
3. Ripple & Noise measurement bandwidth is 0-20
MHz.
4. These power converters require a minimum output
loading to maintain specified regulation.
5. Operation under no-load conditions will not
damage these modules; however, they may not
meet all specifications listed.
Exceeding the absolute maximum ratings of the unit could cause damage.
These are not continuous operating ratings.
Environmental Specifications
Parameter
Operating Temperature
Operating Temperature
Storage Temperature
Humidity
Cooling
Conditions
Ambient
Case
Min.
Max.
Unit
]
]
]
%
6. All DC/DC converters should be externally fused at
the front end for protection.
7. Other input and output voltage may be available,
please contact factory.
8. Specifications subject to change without notice.
-40
+71
-40
+90
-40
+125
---
95
Free-Air Convection
REV:0 2005/04
MINMAX
2
MIW3100 Series
Input Specifications
Parameter
Start Voltage
Under Voltage Shutdown
Model
12V Input Models
24V Input Models
12V Input Models
24V Input Models
Reverse Polarity Input Current
Short Circuit Input Power
Input Filter
All Models
Min.
4.5
8
---
---
---
---
Typ.
6
12
---
---
---
1000
Pi Filter
Max.
8
16
8
16
1
3000
A
mW
VDC
Unit
Output Specifications
Parameter
Output Voltage Accuracy
Output Voltage Balance
Line Regulation
Load Regulation
Ripple & Noise (20MHz)
Ripple & Noise (20MHz)
Ripple & Noise (20MHz)
Over Power Protection
Transient Recovery Time
Transient Response Deviation
Temperature Coefficient
Output Short Circuit
25% Load Step Change
Over Line, Load & Temp.
Dual Output, Balanced Loads
Vin=Min. to Max.
Io=20% to 100%
Conditions
Min.
---
---
---
---
---
---
---
120
---
---
---
Continuous
Typ.
{ 0.5
{ 0.5
{ 0.1
{ 0.3
50
---
---
---
150
{2
{ 0.01
Max.
{ 1.0
{ 2.0
{ 0.3
{ 1.0
75
100
15
---
300
{6
{ 0.02
Unit
%
%
%
%
mV P-P
mV P-P
mV rms
%
uS
%
%/]
General Specifications
Parameter
Isolation Voltage Rated
Isolation Voltage Test
Isolation Resistance
Isolation Capacitance
Switching Frequency
MTBF
MIL-HDBK-217F @ 25 ] ,Ground Benign
Conditions
60 Seconds
Flash Tested for 1 Second
500VDC
100KHz,1V
Min.
1500
1650
1000
---
---
1,000
Typ.
---
---
---
380
300
---
Max.
---
---
---
500
---
---
Unit
VDC
VDC
M[
pF
KHz
K Hours
Capacitive Load
Models by Vout
Maximum Capacitive Load
# For each output
3.3V
6800
5V
6800
12V
6800
{12V #
1000
{15V #
1000
Unit
uF
3
MINMAX
REV:0 2005/04
MIW3100 Series
Input Fuse Selection Guide
12V Input Models
1500mA Slow - Blow Type
24V Input Models
700mA Slow - Blow Type
Input Voltage Transient Rating
150
140
130
120
110
100
Vin ( VDC )
90
80
70
60
50
40
30
20
10
0
10uS
100uS
1mS
10mS
100mS
12VDC Input Models
24VDC Input Models
REV:0 2005/04
MINMAX
4
MIW3100 Series
100
90
Efficiency (%)
100
90
Efficiency (%)
80
70
60
50
Low
Nom
Input Voltage (V)
High
80
70
60
50
Low
Nom
Input Voltage (V)
High
Efficiency vs Input Voltage ( Single Output )
Efficiency vs Input Voltage ( Dual Output )
90
80
70
90
80
70
Efficiency (%)
10
20
40
60
Load Current (%)
80
Efficiency (%)
60
50
40
30
20
100
60
50
40
30
20
10
20
40
60
80
100
Load Current (%)
Efficiency vs Output Load ( Single Output )
Efficiency vs Output Load ( Dual Output )
100
80
Output Power (%)
100LFM
Natural
convection
400LFM
200LFM
60
40
20
0
-40
〜
50
60
70
80
]
90
100
110
Ambient Temperature
Derating Curve
5
MINMAX
REV:0 2005/04