TMP120-48

产品描述120 WATT MEDICAL POWER ADAPTERS
文件大小169KB,共2页
制造商TRUMPower
官网地址http://www.trumpower.com/
下载文档 选型对比 全文预览

TMP120-48概述

120 WATT MEDICAL POWER ADAPTERS

文档预览

下载PDF文档
TRUMPower
D E S C R IP T IO N
The TMP120 series of AC/DC switching power
adapters are for 96 to 120 watts of continuous
output power. They are enclosed in a 94V-1 rated
case with an IEC 320/C14 or C18 inlet to mate with
interchangeable AC power cord for world-wide
use. All models meet CISPR 11 and FCC class B
emission limits, and are designed for medical
applications.
120 WATT MEDICAL POWER ADAPTERS
TMP120 SERIES
Class I, Class II
(LVD)
RoHS
F E AT U R E S
Low safety ground leakage current
Optional output connectors
100% burn-in
9 0 t o 2 6 4 VAC w i d e i n p u t r a n g e
O v e r v o l ta g e a n d o v e r c u r r e n t p r o t e c t i o n s
Optional IEC 320/C18 inlet with class II insulation
C o m p l i a n t w i t h C E C a n d E n e r g y S ta r e f f i c i e n c y
l e v e l I V r e q u i r e m e n ts
No load power consumption less than 0.5W
Av e r a g e a c t i v e e f f i c i e n c y
8 5 %
C o m p l i a n t w i t h R o H S r e q u i r e m e n ts
S a f e t y Sta n d a r d A p p r o va l s
UL 60601-1
CSA C22.2 No. 601.1
TÜV EN60601-1
I N P U T S P E C I F I C AT I O N S
I n p u t v o l ta g e
Input frequency
Input current
90 to 264VAC
47 to 63Hz
1.60A (rms) for 115 VAC
0.80A (rms) for 230 VAC
GENERAL SPECIFICATIONS
Switching frequency:
Power factor:
Efficiency:
Hold-up time:
Line regulation:
Inrush current:
50KHz ~ 110KHz
0.98 typical at 115VAC
85% min.
15 msec minimum at 115VAC
±0.5% maximum at full load
90µA max. @ 115 VAC/60Hz
Earth leakage current
150µA max. @ 230 VAC/50Hz
(Class I)
E n c l o s u r e l e a k a g e c u r r e n t :
90µA max. @ 264 VAC/50Hz
(Class II)
OUTPUT SPECIFICATIONS
Output voltage/current:
Total output power:
Ripple and noise:
Overvoltage protection:
See rating chart
120 watts maximum
2% peak to peak maximum
Provided on output #1 only;
set at 112 -140% of its nominal
output voltage
All outputs protected to short
circuit conditions
All outputs ±0.04%/ºC maximum
Maximum excursion of 4% or
better on all models, recovering
to 1% of final value within 500µs
after a 25% step load change
Overcurrent protection:
Temperature coefficient:
Transient response:
60 amps @ 115VAC or 90 amps
@230VAC, at 25ºC cold start
Withstand voltage:
4000VAC from input to output
1500VAC from input to ground
500VAC from output to ground
MTBF:
150,000 hours minimum at full load at
25ºC ambient, calculated per
MIL-HDBK-217F
EMC Performance (EN60601-1-2: 2001)
E N 5 5 0 11 :
Class B conducted, Class B radiated
FCC:
Class B conducted, Class B radiated
VCCI:
Class B conducted, Class B radiated
EN61000-3-2:
Harmonic distortion, Class A and D
EN61000-3-3:
Line flicker
EN61000-4-2:
ESD, ±8KV air and ±6KV contact
EN61000-4-3:
EN61000-4-4:
EN61000-4-5:
EN61000-4-6:
EN61000-4-8:
E N 6 1 0 0 0 - 4 - 11 :
Radiated immunity, 3V/m
Fast transient/burst, ±2KV
Surge, ±1KV diff, ±2KV com.
Conducted immunity, 3Vrms
Magnetic field immunity, 3A/m
Voltage dips, 30% reduction for 500ms,
60% reduction for 100ms and >95%
reduction for 10ms
E N V I R O N M E N TA L S P E C I F I C AT I O N S
Operating temperature
Storage temperature
Relative humidity
Derating:
0 ºC t o + 6 0 ºC
- 4 0 ºC t o + 8 5 ºC
5% to 95% non-condensing
Derate from 100% at +40ºC
linearly to 50% at +60ºC
Tumbler Technologies + TRUMPower
3350 Scott Blvd., Bldg. 13, Santa Clara, California 95054, USA
Phone: 408-988-6616
Fax: 408-988-6622
email: sales@trumpower.com
Website: www.TRUMPower.com

TMP120-48相似产品对比

TMP120-48 TMP120-15 TMP120-12 TMP120 TMP120-24 TMP120-36 TMP120-19 TMP120-18 TMP120-20 TMP120-30
描述 120 WATT MEDICAL POWER ADAPTERS 120 WATT MEDICAL POWER ADAPTERS 120 WATT MEDICAL POWER ADAPTERS 120 WATT MEDICAL POWER ADAPTERS 120 WATT MEDICAL POWER ADAPTERS 120 WATT MEDICAL POWER ADAPTERS 120 WATT MEDICAL POWER ADAPTERS 120 WATT MEDICAL POWER ADAPTERS 120 WATT MEDICAL POWER ADAPTERS 120 WATT MEDICAL POWER ADAPTERS
提问+线性ccd的二值化,串口大师不显示二进制,求解
线性ccd的二值化,串口大师只显示十六进制,不显示二进制,调了好久,求大神解?...
shadow丶 NXP MCU
雷柏V10RGB幻彩背光游戏鼠标硬垫拆解评测--开箱展示
自收到快递已有三天了,今天才有时间来开箱进行评测。在此首先感谢电子工程世界论坛网站能给电子工程世界论坛的会员一次拆解这款由深圳雷柏科技股份公司生产的无线充电鼠标垫,并进行评测。 ......
cjjh2014 电源技术
ISE仿真的问题
module clk_fenp( clk_in, clk_out, switch_8bit_in ......
eeleader FPGA/CPLD
5438 NRF905 SPI
用5438与NRF905做发送与接收数据的实验,用I/O口模拟SPI时没有问题,但将USCI设置为SPI模式时,无法通信,下面是接收数据的代码,麻烦大家给看一看 void RxPacket(unsigned char *RxBuf){ whi ......
zzbaizhi 微控制器 MCU
推荐中国芯之STC8单片机
本帖最后由 xunke 于 2020-6-29 23:35 编辑 说到STC相信很多小伙伴已经很熟悉了,STC89C51就在当年在学校学单片机的入门芯了。也许很多人以为51单片机已日落西山而转战其他单片机了,但STC ......
xunke 国产芯片交流
有点创意吧 EXCEL 模拟LED电子屏
嘿嘿 今天上班没事 又很怀念LED电子屏 就写一个宏 效果还可以 看看图...
mlyxlpk007 NXP MCU

 
EEWorld订阅号

 
EEWorld服务号

 
汽车开发圈

 
机器人开发圈

About Us 关于我们 客户服务 联系方式 器件索引 网站地图 最新更新 手机版

站点相关: 大学堂 TI培训 Datasheet 电子工程 索引文件: 3  1746  2814  141  2912  41  8  4  15  57 

器件索引   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z

北京市海淀区中关村大街18号B座15层1530室 电话:(010)82350740 邮编:100190

电子工程世界版权所有 京B2-20211791 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号 Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved