10BASE T ISOLATION TRANSFORMER
High Isolation 2000Vrms
Turns Ratio
+2%
2CT:1CT (Pins 1-3:16-14)
1CT:1CT (Pins 6-8:11-9)
Fast Rise Times
Meets ECMA Requirements
PARAMETER
Open Circuit Inductance
Oscillation Voltage = 20mV
Oscillation Frequency = 100.0 KHz
MIN.
150
MAX.
UNITS
µHy
IEEE 802.3 Compatible
(10BASE 2, 10BASE 5, & 10BASE T)
Common Mode
Choke Option
T-14838
Surface Mount Option
(add suffix "G" to part#)
T-13038G
Leakage Inductance
Oscillation Level = 20mV
Oscillation Frequency = 100.0 KHz
Interwinding Capacitance (C
W/W
)
Oscillation Frequency = 100.0 KHz
Primary DC Resistance
Secondary DC Resistance
1.0
µHy
20
pF
0.9
0.9
ohms
ohms
High Potential Test
2 Kv
V
RMS
PHYSICAL DIMENSIONS
All dimensions in inches (mm):
SCHEMATIC DIAGRAM:
6(&
6(&
35,
35,
RHOMBUS INDUSTRIES INC.
FSCM NO. 16714
RHOMBUS P/N:
T-13038
CUST P/N:
DATE:
11/12/96
NAME:
SHEET:
1 OF 1
Rhombus
Industries Inc.
Transformers & Magnetic Products
15801 Chemical Lane, Huntington Beach, CA 92649
Phone: (714) 898-0960
FAX: (714) 896-0971