MIHW2000 Series
3W, Ultra-Wide Input Range DIP, Single & Dual Output DC/DC Converters
Key Features
Efficiency up to 83%
4200VDC Isolation
MTBF > 1,000,000 Hours
4:1 Wide Input Range
Complies With EN55022 Class B
All I/O Clearance and Creepage Distance
2.0 mm Min.
Temperature Performance -40] to +75]
Low Leakage Current
Low Isolation Capacitance
CSA60950-1 Safety Approval
EMI
Low Profile
EN55022
4200
VDC
I/O Isolation
4:1
Wide Range
Minmax's MIHW2000-Series power modules are specially designed to provide ultra-high levels of isolation 4200VDC in a low profile 24-pin DIP
package. Operating input voltage ranges of 9-40VDC, 18-80VDC and 36-160VDC which provide precisely regulated output voltages of 5V, 12V,
{12V and {15VDC.
The -40] to +75] operating temperature range makes it ideal for data communication equipments, mobile battery driven equipments,
distributed power systems, telecommunication equipments, mixed analog/digital subsystems, process/machine control equipments, computer
peripheral systems and industrial robot systems.
The modules have a maximum power rating of 3W and a typical full-load efficiency of 83%, continuous short circuit, EN55022 Class B conducted
noise compliance minimize design-in time, cost and eliminate the need for external filtering.
Absolute Maximum Ratings
Parameter
Input Surge Voltage
( 1000 mS )
24VDC Input Models
48VDC Input Models
110VDC Input Models
Min.
-0.7
-0.7
-0.7
---
---
Max.
50
100
180
260
2,500
Unit
VDC
VDC
VDC
]
mW
Environmental Specifications
Parameter
Operating Temperature
Operating Temperature
Storage Temperature
Humidity
Cooling
Conducted EMI
Conditions
Ambient
Case
Min.
-40
-40
-40
---
Max.
+75
+95
+125
95
Unit
]
]
]
%
Lead Temperature (1.5mm from case for 10 Sec.)
Internal Power Dissipation
Exceeding the absolute maximum ratings of the unit could cause damage.
These are not continuous operating ratings.
Free-Air Convection
EN55022 Class B
1
MINMAX
REV:0 2009/02/04
MIHW2000 Series
Input Specifications
Parameter
Input Voltage Range
Model
24V Input Models
48V Input Models
110V Input Models
Under Voltage Shutdown
24V Input Models
48V Input Models
110V Input Models
Reverse Polarity Input Current
Short Circuit Input Power
Input Filter
All Models
Min.
8
13
26
---
---
---
---
---
Typ.
8.5
15
30
---
---
---
---
---
Pi Filter
Max.
9
17
34
8.5
16
32
0.3
2000
A
mW
VDC
Unit
Output Specifications
Parameter
Output Voltage Accuracy
Output Voltage Balance
Line Regulation
Load Regulation
Ripple & Noise (20MHz)
Ripple & Noise (20MHz)
Ripple & Noise (20MHz)
Over Power Protection
Transient Recovery Time
Transient Response Deviation
Temperature Coefficient
Output Short Circuit
25% Load Step Change
Dual Output, Balanced Loads
Vin=Min. to Max.
Io=100% to 25%
5V Output Models
Other Output Models
Over Line, Load & Temp.
Conditions
Min.
---
---
---
---
---
---
---
---
120
---
---
---
Continuous
Typ.
{0.5
{0.5
{0.3
{0.5
75
100
---
---
---
150
{3
{0.02
Max.
{1.0
{2.0
{0.5
{1.0
100
150
180
15
---
500
{6
{0.05
Unit
%
%
%
%
mV P-P
mV P-P
mV P-P
mV rms
%
uS
%
%/]
General Specifications
Parameter
Isolation Voltage Rated
Isolation Voltage Test
Leakage Current
Isolation Resistance
Isolation Capacitance
Switching Frequency
MTBF
MIL-HDBK-217F @ 25], Ground Benign
Conditions
60 Seconds
Flash Tested for 1 Second
240VAC, 60Hz
500VDC
100KHz,1V
Min.
4200
5000
---
1000
---
---
1000
Typ.
---
---
---
---
7
150
---
Max.
---
---
2
---
13
---
---
Unit
VDC
VDC
uA
M[
pF
KHz
K Hours
3
MINMAX
REV:0 2009/02/04
MIHW2000 Series
Notes :
1. Specifications typical at Ta=+25], resistive load, nominal input voltage, rated output current unless otherwise noted.
2. Transient recovery time is measured to within 1% error band for a step change in output load of 75% to 100%.
3. Ripple & Noise measurement bandwidth is 0-20 MHz.
4. These power converters require a minimum output loading to maintain specified regulation.
5. Operation under no-load conditions will not damage these modules; however, they may not meet all specifications listed.
6. All DC/DC converters should be externally fused at the front end for protection.
7. Other input and output voltage may be available, please contact factory.
8. Specifications subject to change without notice.
Block Diagram
+Vin
LC
Filter
+Vo
+Vin
LC
Filter
+Vo
Com.
-Vo
PWM
Isolation
Ref.Amp
PWM
Isolation
Ref.Amp
-Vo
-Vin
-Vin
Input Voltage Transient Rating
320
300
280
260
240
220
Vin ( VDC )
200
180
160
140
120
100
80
60
40
0
10uS
100uS
1mS
10mS
100mS
24VDC Input Models
48VDC Input Models
110VDC Input Models
REV:0 2009/02/04
MINMAX
4
MIHW2000 Series
100
90
80
70
60
50
100
90
Efficiency (%)
80
70
60
50
Efficiency (%)
Low
Nom
Input Voltage (V)
High
Low
Nom
Input Voltage (V)
High
Efficiency vs Input Voltage ( Single Output )
Efficiency vs Input Voltage ( Dual Output )
90
80
70
Efficiency (%)
60
50
40
30
20
10
20
40
60
Load Current (%)
80
100
100
90
Efficiency (%)
80
70
60
50
40
30
10
20
40
60
80
100
Load Current (%)
Efficiency vs Output Load ( Single Output )
Efficiency vs Output Load ( Dual Output )
100
80
Output Power (%)
100LFM
Natural
convection
400LFM
200LFM
60
40
20
0
-40
½
50
60
70
80
]
90
100
110
Ambient Temperature
Derating Curve
5
MINMAX
REV:0 2009/02/04