Triacs
INCHANGE
BT134-600B
Features
·With
TO-126P package
·PIN
DESCRIPTION
1 .main terminal 1
2 .main terminal 2
3. gate
tab. main terminal 2
·For
use in applications requiring high bidirectional transient
and blocking voltage capability and high thermal cycling
performance. Typical applications include motor control,
industrial and domestic lighting,heating and static switching.
QUICK REFERENCE DATA
SYMBOL
PARAMETER
VALUE
UNIT
V
DRM
V
RRM
I
T(AV)
I
TSM
P
GM
P
G(AV)
T
stg
T
j
Repetitive peak off-state voltage
Repetitive peak off-state voltage
Average on-state current
Non-repetitive peak on-state current
Peak gate power
Average gate power
Storage temperature
Operating junction temperature
600
600
2
20
5
0.5
-45½150
110
V
V
A
A
W
W
℃
℃
TO-126P
ELECTRICAL CHARACTERISTICS
(Tj = 25°C, unless otherwise specified)
SYMBOL
PARAMETER
CONDITIONS
MIN
MAX
UNIT
V
DRM
V
RRM
Repetitive peak off-state voltage
Repetitive peak reverse voltage
I
D
=0.1mA
I
D
=0.5mA
V
D
=12V;R
L
= 100
Ω
T2+ G+
T2+ G-
T2- G-
T2- G+
600
600
6
6
6
10
1.7
8
1.5
1.5
1.5
1.8
T2+ G-
T2- G-
T2- G+
V
V
I
GT
Gate trigger current
mA
V
T
I
H
On-state voltage
Holding current
I
T
=4A
I
T
=0.1A;
I
GT
= 20m A
V
D
=12V; R
L
= 100
Ω
T2+ G+
V
mA
V
GT
Gate trigger voltage
V