Bussmann
®
5mm x 20mm Ferrule Fuses
Medium Time-Delay
Dimensional Data
38.10mm
(±.38)
5.54mm
(±.20)
GMC
GMC-V
100mA
125mA
150mA
200mA
250mA
315mA 300mA
400mA
500mA
750mA
800mA
1A
1.5A
1.6A
2A
2.5A
3A
3.5A
4A
5A
6A
6.3A
7A
8A
10A
Time-Current Characteristic Curves–Average Melt
62mA
80mA
100
10mm 20mm
(±2.0) (±0.5)
21.10mm
(±.81)
AMPERE
RATING
5.2mm
(+0.1/-0.2)
.81 (REF)
38.10mm
(±.38)
10
Glass tube - end caps: nickel
or silver-plated brass.
CATALOG SYMBOL: GMC
MEDIUM TIME-DELAY
63mA - 6.3A UL LISTED, STD. 248-14
(GUIDE #JDYX, FILE #E75865)
7A - 8A UL RECOGNIZED
(GUIDE #JDYX2, FILE #E75865)
TIME IN SECONDS
1
.1
Limits for Pre-arcing Time
In
50mA - 10A
1.35 In
MAX
60 min.
2.0 In
MAX
2 min.
10 In
MIN
10 ms.
1.1 In:
Æt ²
70°C, 50mA - 6.3A.
CURRENT IN AMPERES
Product
Symbol
Lead
Ampere
Rating
GMC
Package Code
Blank
(None)
V
Axial Leads
.032” x 1.5”
Copper Tinned
Markings:
MFG mark, Rated Current, Rated Voltage, Product Symbol,
Approvals where Applicable.
CE logo denotes compliance with European Union Low Voltage Directive
(50-1000 VAC, 75-1500 VDC). Refer to BIF document #8002 or contact
Bussmann Application Engineering at 314-527-1270 for more information.
12-18-98
SB98107
Rev. A
Form No. GMC
Page 1 of 2
BIF Doc #2018
100
10
Packaging & Ordering Information:
.1
1
.01
Bussmann
®
5mm x 20mm Ferrule Fuses
Medium Time-Delay
Electrical Characteristics
Current
Rating
(In)
50mA
63mA
80mA
100mA
125mA
150mA
160mA
200mA
250mA
300mA
315mA
400mA
500mA
600mA
630mA
700mA
750mA
800mA
1A
1.25A
1.5A
1.6A
2A
2.5A
3A
3.15A
3.5A
4A
5A
6A
6.3A
7A
8A
10A
35A/250 VAC
10kA/125 VAC
p.f. = 0.7 - 0.8
Rated
Voltage
(VAC)
Breaking
Capacity
Voltage
Drop
(mV) max.
1600
1400
1300
1200
1000
800
750
600
520
520
470
500
390
350
360
330
320
310
240
190
190
160
130
130
130
130
130
130
130
130
130
130
130
130
Pre-arcing
Value
(I
2
t) (A
2
s) typ.
0.00027
0.0027
0.0050
0.0094
0.014
0.022
0.022
0.032
0.046
0.081
0.081
0.18
0.41
0.60
0.66
0.85
0.85
0.85
1.8
3.4
5.4
5.8
8.9
13
19
23
25
36
58
88
110
150
200
300
GMC
GMC-V
CSA
U.R.
U.L.
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
250
100A/250 VAC
10kA/125 VAC
p.f. = 0.7 - 0.8
10kA/125 VAC
p.f. = 0.7 - 0.8
125
200A/125 VAC
p.f. = 1.0
The only controlled copy of this BIF document is the electronic read-only version located on the Bussmann Network Drive. All other copies of this BIF document are by definition uncontrolled. This bulletin is intended to
clearly present comprehensive product data and provide technical information that will help the end user with design applications. Bussmann reserves the right, without notice, to change design or construction of any
products and to discontinue or limit distribution of any products. Bussmann also reserves the right to change or update, without notice, any technical information contained in this bulletin. Once a product has been select-
ed, it should be tested by the user in all possible applications.
12-18-98
SB98107
Rev. A
Form No. GMC
Page 2 of 2
BIF Doc #2018
JIS