3 A (resistive) Max. Continuous Load (Output) Current
264V AC, 48V DC or 125V DC Max. Load Voltage Range Options
5…24V DC or 110/220V AC Control (Input) Voltage Options
LED Indicator (Optional) For Input/Logic ON/OFF Status Monitoring
700-HN103, 700-HN104, or 700-HN128 Socket Compatible
Compatible with 700-AT1 or 700-AT2 Timer Module
Table Of Contents
Product Selection . . . . . . .
Accessories . . . . . . . . . . . .
Specifications . . . . . . . . . .
Approximate
Dimensions . . . . . . . . . . . .
37
38
39
41
Product Selection
Factory-
stocked
Item
(Single
Pack)
✔
✔
✔
✔
✔
✔
✔
✔
✔
Input-to-Output
Isolation Method
Zero Cross
Function
LED
Indicator
Rated Output (Load)
Max. Current and Voltage
Range
3 A @100…240V AC
Rated Input Control
Voltage
5…24V DC
100/110V AC
200/220V AC
24V DC
5…24V DC
4…24V DC
24V DC
4…24V DC
5…24V DC
Cat. No.
700-SCZY3Z25
700-SCZY2A1
700-SCZY2A2
700-SCTY3Z24
700-SCNY3Z25
700-SCZN3Z26
700-SCTN3Z24
700-SCNN3Z26
700-SCNN2Z25
Photocoupler
Phototriac
Photocoupler
Phototriac
Yes
Yes
No
No
Yes
No
No
2 A @ 100…240V AC
3 A @100…240V AC
3 A @ 4…48V DC
3 A @ 100…240V AC
3 A @ 4…48V DC
2 A @ 5…110V DC
Photocoupler
N/A
37
Bulletin 700-SC
Solid-State Relays
Accessories
Description
Pkg. Quantity
Cat. No.
Factory-stocked Item
Screw Terminal Socket — Panel or DIN Rail
Mounting; Guarded Terminal Construction
Order must be in ten or multiples of ten
Cat. No. 700-HN103
1
700-HN103
✔
Cat. No. 700-HN104
Screw Terminal Socket – Panel or DIN Rail
Mounting. Guarded Terminal Construction
14-blade miniature socket for use with
Bulletin 700-SC relays. This socket has coil
and contact separation as well as the ability
to plug in optional plug in modules (700-A**
accessories: LED, Surge Suppression,
Timing Modules)
10
700-HN104
✔
Screw Terminal Base Socket — Panel or
DIN Rail Mounting; Open Style
Construction
Order must be in multiples of ten
Cat. No. 700-HN128
10
700-HN128
✔
DIN Rail Mounting Pack
Standard 35 x 7.5 mm DIN Rail, 1 meter long,
10 rails per package. Order must be for 10
rails or multiples of 10.
Cat No. 199-DR1
10
199-DR1
✔
Pre-printed identification tags —
contains
10 sheets of pre-printed and blank tags. Each
sheet contains 13 sets of the markings
CR…9CR, TR…9TR, M…9M, F, R, 1S, and
117 blank tags. Tags are peel-off with sticky
backing for easy placement on relays.
Blank identification tags —
contains 10
sheets of blank identification tags for
customer specialized printing. Each sheet
contains 546 blank tags. Tags are peel-off
with sticky backing for easy placement on
relays.
10
700-N40
10
700-N41
Retainer Clip
Secures relay in socket. Order must be for
10 clips or multiples of 10.
10
700-HN114(B)➊
✔
Sample Retainer Clips
ON-Delay Time Module
Voltage Range: 12…24V AC/DC
used with 700-HN153 socket
One Shot Timing Module
Voltage Range: 12…24V AC/DC
used with 700-HN153 socket
1
700-AT1
1
700-AT2
➊
Series B retainer clip must be used with Bulletin 700-SC
38
Bulletin 700-SC
Solid-State Relays
Specifications
Control/Input Ratings
Cat. No.
700-SCZY3Z25
700-SCZY2A1
700-SCZY2A2
700-SCTY3Z24
700-SCNY3Z25
700-SCZN3Z26
700-SCTN3Z24
700-SCNN3Z26
700-SCNN2Z25
Rated Control
Voltage
5…24V DC
100/110V AC
200/220V AC
24V DC
5…24V DC
4…24V DC
24V DC
4…24V DC
5…24V DC
Operating Control Voltage
Range
4…28V DC
75…125V AC
150…250V AC
19.2…28.8V DC
4…28V DC
3…28V DC
19.2…28.8V DC
3…28V DC
Impedance
15 mA max.
➊
41 KΩ± 20%
72 KΩ
±
20%
2 KΩ
±
20%
1.5 KΩ + 20%/–10%
➋
15 mA max.
➊
2 kΩ
±
20%
1.5 KΩ + 20%/–10%
➋
Load/Output Ratings
Cat. No.
—
700-SCZY3Z25
700-SCTY3Z24
700-SCZN3Z26
700-SCTN3Z24
700-SCZY2A1
700-SCZY2A2
700-SCNN3Z25
700-SCNY3Z26
700-SCNN2Z25
➊
➋
➌
➍
100…240V AC
4…48V DC
5…110V DC
3…52.8V DC
3…125V DC
100…240V AC
75…264V AC
0.1 A
0.1 A
0.1 A
2A
3A
2A
18 A (10 ms)
10 A (10 ms)
0.1 A
3A
45 A (@50/60 Hz, 1 cycle)
Rated
Load Voltage
—
Applicable Load
Load Voltage Range
—
Continuous Load Current
(Resistive)
Min.
Max.
➍
Max. Inrush Current
➌
—
Control Voltage Levels
Pick-up Voltage
4V DC max.
75V AC max.
150V AC max.
19.2V DC max.
4V DC max.
3V DC max.
19.2V DC max.
3V DC max.
1V DC min.
Drop-out Voltage
1V DC min.
20V AC min.
40V AC min.
With constant current input circuit system. SSR impedance varies with a change in input voltage.
Input impedance attains its maximum at the operating voltage.
If the SSR operation is continuous ON/OFF, this value should be reduced by 50%. Refer to “Inrush Current Resistivity” graphs on page 40 for details.
Refer to the following "Load Current Versus Ambient Temperature Characteristics" graphs on page 40 for additional load current details.
Characteristics
Cat. No.
Load Switching Method/Device
700-SCZ….
Triac
1/2 of load power source + 1 ms
max. (DC input)
Pick-up Time
3/2 of load power source + 1 ms
max. (AC input)
1/2 of load power source + 1 ms
max. (DC input)
Drop-out Time
3/2 of load power source + 1 ms
max. (AC input)
Output ON Voltage Drop
Output Leakage Current
Output
V
DRM
, V
CEO
(V)
Output di/dt (A/uS)
Output dv/dt (V/uS)
Output
I
2
t (A
2
S)
Output Tj °C Max.
Insulation Resistance
Dielectric Strength
Vibration Resistance (max.)
Shock Resistance (max.)
Ambient Temperature
1.6 V (RMS) max
5 mA max (@ 100 V AC)
10 mA max (@ 200 V AC)
600
50
250
18
125
1/2 of load power source +
1 ms max
1.6V (RMS)
2.5 mA max
(@ 100 V AC)
5 mA max (at 200 V AC)
600
50
250
18
125
100 MΩ min (@ 500V DC)
1,500 V AC, 50/60 Hz for 1 minute
10…55 Hz, 1.5 mm double amplitude (10 G)
1,000 m/s
2
(100 G)
Operating: -30°C…80°C (-22...176°F) with no icing or condensation
Storage: -30°C…100°C (-22...212°F) with no icing or condensation
1 ms max
0.5 ms max
0.5 ms max
700-SCT
700-SCNN3…
Transistor
700-SCNN2…
2 ms max
2.5 ms max
1.5 V max.
5 mA max (@ 50 V DC)
1.5V max.
0.1 mA max (@ 100 V
DC)
80
—
—
—
150
80
—
—
—
150
39
Bulletin 700-SC
Solid-State Relays
Specifications, Continued
Characteristics
Standards
Ambient Humidity
Weight
UL508, CSA C 22.2,
CE, VDE
Operating: 45%…85% (no condensation)
Approx. 50 g
Load Current Versus Ambient Temperature Characteristics
700-SC_ _3...
700-SC_ _2...
Load current (A)
Load current (A)
Ambient temperature (°C)
Ambient temperature (°C)
Inrush Current Resistivity➊
700-SCZ....
700-SCT...
700-SCNN3...
700-SCNY3
700-SCNN2...
Inrush current (A. Peak)
Inrush current (A. Peak)
Inrush current (A. Peak)
10
20
Energizing time (ms)
Energizing time (ms)
Energizing time (ms)
➊
Inrush current resistivity is the ability of an SSR to withstand a large surge current for a short period of time. Surges are considered non-repetitive (max. repeatability
once every 2…5 seconds). Keep the inrush current to half the rated value if it occurs repetitively. Exceeding the non-repetitive inrush current will damage the SSR.
40
Bulletin 700-SC
Solid-State Relays
Approximate Dimensions
Note: Bulletin 700-SC is compatible with the 700-HN103, 700-HN104, and 700-HN128 sockets. All units in millimeters unless otherwise indicated. Dimensions
are not intended for manufacturing purposes.
Terminal Arrangement/
Internal Connections
(Bottom View)
1
28 max.
5
9
13
–
–
Cat, No 700-SC…
➊
4
8(+)
Load
12(–)
(–)
14
+
Input voltage
+
Load
(+)
Load
power
supply
21.5 max.
36.5 max.
42.5 max.
Input
Note:
The plus and minus symbols shown
in parentheses are for DC loads.
➊
Bulletin 700-SC is compatible with cat. nos. 700-HN103, -HN104, and -HN128 socket.
Basic Application Considerations For Bulletin 700-SC
Connection
For DC Load Switching, Bulletin 700-SC will operate properly if the load is connected to either the positive or negative SSR load terminal.
High-density Mounting of Multiple SSRs
If multiple relays are mounted side by side, be aware that the outer wall of each SSR works as a radiator.
The SSR casing serves to dissipate heat. Install the relays so that they are adequately ventilated. If poor ventilation is unavoidable, reduce the load current by half.
Protective Component
When controlling AC inductive loads, connect an inrush/surge absorbing device (varistor) across the SSR load terminals. If the SSR has built-in surge
suppression (Bulletins 700-SE and 700-SH) and additional surge suppression is required, connect the varistor across the terminals of the load device . Select
a varistor that meets the conditions of the load voltage outlined in the table below. Note: For additional details applying solid-state relays, refer to pub. number
700-AT001A-EN-E, "Solid-State Relay Application Guide." Document available at www.theautomationbookstore.com.