Bulletin 100S-D safety contactors are designed to provide safe
isolation of hazardous motion loads, utilizing “mirror contact”
performance. Mirror contacts provide reliable indication about the
open/closed status of the main power poles.
CE marked for all applicable directives
CSA Certified
UL Listed
SUVA Certified
Features
•
•
•
•
45…220 kW @500V
60…600 Hp @460V
75…700 Hp @575V
Electronic and Conventional Coils
AC & DC
Integrated PLC Interface
Low Power Pick-Up & Hold-In
Wide Voltage Ranges
• Complete Range of Accessories
• Environmentally-Friendly
• Compact Dimensions
9-9
Contactors & Control Relays
Safety Contactors
100S-D
Product Selection
3-pole AC Contactors
• Conventional and Electronic AC Coils
• 3 Main Contacts
• Non-Reversing
I
e [A]
60°C
40°C
Switching of 3-Phase Motors—AC-2, AC-3
kW (50 Hz)
Hp (60 Hz)
Auxiliary Contacts
N.O.
N.C.
➊
AC-3 AC-1 230V 400V 415V
95
110
140
180
210
250
300
420
630
860
⊗
160
160
250
250
350
350
450
500
800
1000
25
32
45
55
63
80
90
132
200
250
50
55
75
90
110
132
160
220
355
500
50
55
75
100
110
150
160
250
355
500
500V
55
63
690V
80
100
1000V 200V 230V 460V 575V
45
55
75
90
110
133
163
225
425
425
25
40
40
50
60
75
100
150
200
250
30
40
50
60
75
100
125
175
250
300
60
75
100
150
150
200
250
350
500
600
75
100
125
150
200
250
300
400
600
700
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
Catalogue Number
100S-D95⊗22C
100S-D110⊗22C
100S-D140⊗22C
100S-D180⊗22C
100S-D210⊗22C
100S-D250⊗22C
100S-D300⊗22C
100S-D420⊗22C
100S-D630⊗22C
100S-D860⊗22C
80/90➌ 110/132➌
90/110➌ 132/160➌
150
160
200
300
450
560
200
250
300
425
500
600
AC Coil Voltage Code
The Catalogue Number as listed is incomplete. Select a coil voltage code from the table below to complete the Catalogue Number. Example: 120V 60 Hz:
Catalogue Number
104S-C09⊗210C
becomes Catalogue Number
104S-C09D210C.
Conventional Coil
100S-D95…
100S-D180
100S-D95…
100S-D110
V
50 Hz
60 Hz
50/60 Hz
24
K
J
KJ
48
Y
X
—
100
—
—
KP
110
D
—
KN
120
—
D
—
200
—
—
KG
208
—
H
—
220…
230
A
—
—
230
—
—
KF
240
T
A
KA
277
—
T
—
380…
400
N
—
—
415
B
—
—
440
G
N
—
480
—
B
—
500
M
—
—
550
C
—
—
600
—
C
—
Electronic Coil
w/PLC Interface
➋
100S-D95…
100S-D250
100S-D300…
100S-D420
100S-D630…
100S-D860
V
50/60 Hz
50/60 Hz
50/60 Hz
24
EJ
—
—
42…
64
EY
EY
—
100
EP
EP
EP
110…
130
ED
ED
ED
200
EG
EG
EG
208…
277
EA
EA
EA
380…
415
EN
EN
EN
440…
480
EN
EN
EB
500
EN
EN
EM
600
—
—
EC
➊
The N.C. contacts meet IEC 60947-4 Annex F requirements to mirror contact performance. The N.C. mirror contacts are wired in series or parallel and must
be used as monitoring contacts with feedback to the safety circuit.
➋
Signal voltage of the Cat. No. 100S-D… electronic interface:U
e
: 24V DC/I
e
: 15 mA
Pick-Up Voltage: 13.0V DC…30.2V DC
Drop-Out Voltage: -3.0V DC…+5.0V DC
➌
Higher kW rating only applies to contactors with electronic coil.
The Catalogue Number as listed is incomplete. Select a coil voltage code from the table below to complete the Catalogue Number. Example: 120V 60 Hz:
Catalogue Number
104S-C09⊗210C
becomes Catalogue Number
104S-C09D210C.
Conventional Coil
100S-D95…100S-D140
➋
V
DC
24
ZJ
48
ZY
110
ZD
125
ZS
220
ZA
250
ZT
Electronic Coil
w/EI Interface
➌
100S-D95…100S-D300
100S-D420
100S-D630…860
V
DC
DC
DC
24
EZJ
—
—
48…72
EZY
EZY
—
110…130
EZD
EZD
ED
200…255
EZA
EZA
EA
➊
The N.C. contacts meet IEC 60947-4 Annex F requirements to mirror contact performance. The N.C. mirror contacts are wired in series or parallel and must
be used as monitoring contacts with feedback to the safety circuit.
➋
For conventional DC coil only. The pickup winding must be interconnected with the N.C. late-breaking auxiliary contacts.
➌
Signal voltage of the Cat. No. 100S-D… electronic interface:U
e
: 24V DC/I
e
: 15 mA
Pick-Up Voltage: 13.0V DC…30.2V DC
Drop-Out Voltage: -3.0V DC…+5.0V DC
➍
Higher kW rating only applies to contactors with electronic coil.