Notice for TAIYO YUDEN products
Please read this notice before using the TAIYO YUDEN products.
REMINDERS
■
Product information in this catalog is as of October 2012. All of the contents specified herein are subject to change
without notice due to technical improvements, etc. Therefore, please check for the latest information carefully be-
fore practical application or usage of the Products.
Please note that Taiyo Yuden Co., Ltd. shall not be responsible for any defects in products or equipment incorpo-
rating such products, which are caused under the conditions other than those specified in this catalog or individual
specification.
■
Please contact Taiyo Yuden Co., Ltd. for further details of product specifications as the individual specification is
available.
■
Please conduct validation and verification of products in actual condition of mounting and operating environment
before commercial shipment of the equipment.
■
All electronic components or functional modules listed in this catalog are developed, designed and intended for
use in general electronics equipment.(for AV, office automation, household, office supply, information service,
telecommunications, (such as mobile phone or PC) etc.). Before incorporating the components or devices into any
equipment in the field such as transportation,( automotive control, train control, ship control), transportation signal,
disaster prevention, medical, public information network (telephone exchange, base station) etc. which may have
direct influence to harm or injure a human body, please contact Taiyo Yuden Co., Ltd. for more detail in advance.
Do not incorporate the products into any equipment in fields such as aerospace, aviation, nuclear control, subma-
rine system, military, etc. where higher safety and reliability are especially required.
In addition, even electronic components or functional modules that are used for the general electronic equipment,
if the equipment or the electric circuit require high safety or reliability function or performances, a sufficient reliabil-
ity evaluation check for safety shall be performed before commercial shipment and moreover, due consideration to
install a protective circuit is strongly recommended at customer's design stage.
■
The contents of this catalog are applicable to the products which are purchased from our sales offices or distribu-
tors (so called
“TAIYO
YUDEN’ official sales channel”
s
).
It is only applicable to the products purchased from any of TAIYO YUDEN’ official sales channel.
s
■
Please note that Taiyo Yuden Co., Ltd. shall have no responsibility for any controversies or disputes that may oc-
cur in connection with a third party's intellectual property rights and other related rights arising from your usage of
products in this catalog. Taiyo Yuden Co., Ltd. grants no license for such rights.
■
Caution for export
Certain items in this catalog may require specific procedures for export according to
“Foreign
Exchange and For-
eign Trade Control Law”of Japan,
“U.S.
Export Administration Regulations” and other applicable regulations.
,
Should you have any question or inquiry on this matter, please contact our sales staff.
1
3
DC/DC CONVERTER(T-78KL SERIES)
■
DESCRIPTION
◦
LDOs became popular to use wide variety of circuits because easy to
use, however applications that have large difference of input/output
voltage, the following actions may be required to get several hundreds
milli-amperes output current under a restriction of acceptable loss.
◦
Radiation to chassis
◦
Addition of heat sink
◦
Multi use of LDO
In this case, it will be happened not only power loss but also heat and space
issues.
We have developed a DC/DC converter that has both same form factor and
pin configuration to TO-220 size LDO, and higher efficiency to resolve those
issues. This DC/DC converter has realized a 1.5A output level without heat
sink.
※We
have also line up a DC/DC converter module that is 90 deg
bended of its lead.
■
FEATURES
◦
Same pin configuration to TO-220 size LDO.
◦
Applicable to 1.5A output without heat sink
◦
Embedded short circuit protection at output (Automatically reset )
◦
Output Voltage:12V/5.0V/3.3V
■
BLOCK DIAGRAM
Vin
Vout
■
OUTLINE DIMENSIONS
12.5±0.2
FUNCTIONAL MODULES
T-78KL
Series
Cin
Cout
18.0±0.3
Cin, Cout:
(Optional) if necessary, please add input/output capacitors.
The module already includes both capacitors inside.
5.2Typ.
2.54×2
5.7Max.
1.8Max.
Unit : mm
■
ABSOLUTE MAXIMUM RATINGS
Parameter
Input Voltage
Operating Tempera-
ture Range
Storage Temperature
Range
Operating Humidity
Range
Storage Humidity
Range
Symbol
Vin
Topr
Tstg
Hopr
Hstg
Ratings
+30.0
-20½+85
-30½+85
10½90
10½90
Unit
V
℃
℃
%RH
%RH
No
Condensation
Remark
■
ELECTRICAL CHARACTERISTICS
●T-78KL120
12V Voltage Type)
(
Parameter Symbol
Conditions
Ratings
Unit
min. typ. max.
V
V
A
%
Remark
ー
ー
With temperature
derating
Ta=25℃
Input
Vin
ー
16.0
28.0
Voltage
Output
Vout
ー
11.4 12.0 12.6
Voltage
Output
Iout
ー
0.0
1.3
Current
Conversion
ef
Vin=16V、Iout=1.3A
-
96.0
-
Efficiency
●T-78KL050
5V Voltage Type)
(
Parameter Symbol
Conditions
Ratings
Unit
min. typ. max.
V
V
A
%
Remark
ー
ー
With temperature
derating
Ta=25℃
Input
Vin
ー
7.0
28.0
Voltage
Output
Vout
ー
4.75 5.00 5.25
Voltage
Output
Iout
ー
0.0
1.5
Current
Conversion
ef
Vin=12V、Iout=1.5A
-
91.0
-
Efficiency
●T-78KL033
3.3V Voltage Type)
(
Parameter Symbol
Conditions
Ratings
Unit
min. typ. max.
V
V
A
%
Remark
ー
ー
With temperature
derating
Ta=25℃
Input
Vin
ー
5.3
28.0
Voltage
Output
Vout
ー
3.135 3.300 3.465
Voltage
Output
Iout
ー
0.0
1.5
Current
Conversion
ef
Vin=12V、Iout=1.5A
-
87.0
-
Efficiency
▶