rev.
page
page
date
date
1 of 3
01/2008
PART NUMBER:
VSBU-150 series
DESCRIPTION:
single output switching power supply
features
wide input voltage range: 90~264 V ac, 47~63 Hz
internal EMI filter
single output
input connector mates with Molex housing 09-50-3051
and Molex 2478 series crimp terminal
• output connector mates with Molex housing 09-50-3061
(or 09-50-3081) and Molex 2478 series crimp terminal
• output voltage available from 9 to 48 V dc
• input surge current and over load protection
• over voltage protection (crowbar design)
• size: 3 x 5 x 1.09 inches
• class I insulation
• 2 year warranty
•
•
•
•
model
number
VSBU-150-9
VSBU-150-12
VSBU-150-15
VSBU-150-18
VSBU-150-24
VSBU-150-30
VSBU-150-36
VSBU-150-48
output
voltage
9 V dc
12 V dc
15 V dc
18 V dc
24 V dc
30 V dc
36 V dc
48 V dc
output
current
16 A
12.5 A
10 A
8.33 A
6.25 A
5A
4.17 A
3.13 A
total
regulation
±5%
±5%
±5%
±4%
±3%
±2%
±2%
±2%
max
output power
144 W
150 W
150 W
150 W
150 W
150 W
150 W
150 W
INPUT
parameter
input frequency
input voltage
input current
inrush current
leakage current
conditions/description
output power derated from 85-90 V ac
AC input of 115 V ac
AC input of 230 V ac
measured at 115 V ac at full load, cold start
measured at 230 V ac at full load, cold start
measured at 240 V ac
min
47
90
nom
max
63
264
2.0
0.8
12
26
0.5
15
30
0.75
units
Hz
VAC
A
A
A
A
mA
20050
SW
112
th
Ave. Tualatin, Oregon
97062
phone
503.612.2300
fax
503.612.2382
rev.
page
date
2 of 3
01/2008
PART NUMBER:
VSBU-150 series
DESCRIPTION:
single output switching power supply
OUTPUT
parameter
ripple and noise
line regulation
load regulation
temperature drift
rise time
hold-up time
conditions/description
min
nom
0.5%
0.5%
3%
max
+1%
+1%
+5%
+0.04%
4
units
-0.04%
16
mS
mS
PROTECTION CIRCUIT
parameter
output over current
over voltage
conditions/description
min
110
112
nom
max
150
132
units
%
%
GENERAL
parameter
operating temp.
storage temp.
operating humid.
storage humid.
isolation voltage
(HI-POT)
RoHS
safety
conditions/description
min
0
-40
5%
5%
50
4242
2121
nom
max
70
85
95%
95%
units
ºC
ºC
RH
RH
MΩ
V dc
V ac
non-condensing
non-condensing
500 V dc test voltage
primary to secondary
primary to ground
yes
approved to UL/cUL, TUV-Baurart, CE, CISPR-22 class B, FCC part 15 class B, CB
note:
1. to meet the standard of EN61204-3 class B, use the external noise filter between L and N (refer to manual)
20050
SW
112
th
Ave. Tualatin, Oregon
97062
phone
503.612.2300
fax