SMS IP Series
SMS IP: high voltage sealed plastic connector
A connector designed for indoor railway equipments, using the standard
Ø 1.6 contact.
Safe
Finger proof
High operating voltage up to 500 V
CEN / TS 45-545
NF F 16-101/16-102
IP66 & IP67
1 stainless steel latch
NF F 61-030 derivated
Compliant to fire and
smoke standards
Sealed
Easy to handle
Designed for railways
SMS IP Series
|
SOURIAU on the railway market
E
ironmen
nv
t
Safety
The SOURIAU solution offers a wide range
of connector layouts providing a simplified
process from purchasing to harnessing: 1
type of contact to order, to manage, to stock,
to crimp for a wide range of connectors.
SOURIAU’s standardisation policy is the best
compromise between technology and cost.
SOURIAU connectors ensure the continuity
of the network with railway qualified
connectors integrating new technologies:
copper contacts, Quadrax and fibre optics to
transfer high speed Ethernet and other data
protocols.
SOURIAU, along with its customers is
committed to the research of energy
efficiency and sustainability.
The use of lightweight materials, fiber optics
and high contact density contribute to the
weight reduction of train equipments and
help railway operators to save energy.
2
SMS IP Series
|
Technical features
(NF F 61-030 derivated)
Mechanical
•
Durability:
500 mating/unmating
•
Vibrations & shocks:
EN 61-373 Cat.2
•
Locking system:
1 metallic latch - Audible "Click"
•
Keying system:
3 different positions
Material
•
Plug & receptacle:
black thermoplastic
•
Grommet & interfacial seal:
light grey silicone
•
Latch:
stainless steel
Environmental
•
Fire resistance, toxicity & smoke opacity:
R23/HL3 following CEN/TS 45-545
I3/F2 2 following NF F 16-101/16-102
•
RoHS:
compliant
•
Damp heat:
21 days / 40°C / 95% RH
•
Operating temperature:
-50°C to +100°C
•
Fluids:
NF F 61-030
•
Corrosion:
500 hours salt spray
Electrical
•
Current rating per contact:
15 A maxi
•
Operating voltage:
≤ 500 Vdc / ≤ 380 Vac following NF F 61-030
500 Vdc/ac following EN 50-124-1
•
Creepage distances (unmated):
> 12 mm
•
Clearance distances (unmated):
> 8 mm
•
Withstanding voltage:
3250 V
•
Insulation resistance:
≥ 5000 MΩ
•
Contacts resistance:
≤ 2.5 mΩ
Sealed version (SMS IP67)
•
Sealing:
IP66 & IP67 - Following CEI 60-529
• Delivered with pre-mounted grommets and interfacial seal
• IP rating is ensured if the grommets are in their cavities.
Ordering information
SMS IP SERIES
Contact layout:
3 – 6 – 12
Contact type:
P:
Plug for female contacts
R:
Receptacle for male contacts
Application:
IP67:
Sealed version
IP20:
Non sealed version - delivered without grommet
Contacts:
-:
Without contact
K01:
With contacts RM16M23K or RC16M23K
K02:
With contacts RM14M23K or RC14M23K
SMS
3
P
IP67
-
Contacts
• Standard crimp machined contact #16 compatible with EN 50-306-2 & EN 50-264-3-1 wires
Contact
size
Wire size
Type
AWG
20-16
#16 Ø 1.6
MM
For other contact type consult us
Part number
Max wire Ø mm
1.8
2.28
Male
RM16M23K
RM14M30K
Female
RC16M23K
RC14M30K
mm2
0.5-1.5
1.5-2.5
Mini
insulator
Ø mm
1.15
1.15
Max
insulator
Ø mm
3.8
3.8
Machined
16-14
3
SMS IP Series
|
Dimensions & weight
Plug
L1
Receptacle
L3
SMS3IP..
A
B
L1
L2
C
D
Ø
L4
L3
SMS6IP..
A
C
Ø
D
L3
L4
B
L1
L2
SMS12IP..
A
C
Ø
B
D
L4
Weight *±0.2 g.
IP20
13.3 g
16.4 g
16.3 g
20.3 g
40 g
48 g
IP66 & IP67
16.1 g
17.4 g
18.3 g
22.3 g
45 g
53 g
L2
Part number
Plug
SMS3PIP..
SMS3RIP..
SMS6PIP..
SMS6RIP..
SMS12PIP..
SMS12RIP..
* weight of the connector without contact
Receptacle
Layout
3
3
6
6
12
12
A
18
-
23
-
35
-
B
26
-
23
-
46
-
L1
77
-
77
-
77
-
L2
42
-
42
-
42
-
C
-
20
-
24
-
30
D
-
35
-
35
-
54
L3
-
83
-
83
-
83
L4
-
40
-
40
-
40
Ø
-
3.2
-
3.2
-
3.2
Panel cut out
A
SMS3IP..
SMS6IP..
SMS12IP..
28.2
28.2
47.4
A
ØG
ØG
B
F
E
F
ØG
D
B
18.3
25.1
31.4
C
23.3
23.3
42.5
A
D
12.5
12.5
12.5
E
9.6
8.5
26.3
A
F
F
9.6
4
4
ØG
3.2
3.2
3.2
SMS3IP..
SMS6IP..
ØG
SMS12IP..
All layout
A
E
B
E
B
C
Note : all dimensions are in mm
C
C
Fixation on a panel
Fixation on a panel
Fixation on a panel
Fixation on a board
4
SMS IP Series
|
Assembly instructions
7.1 mm
Crimp contacts on wires
• Strip each wire to the lenght indicated.
Crimping tools
AF8
FT8
MH86164G
MH860
TP1142
Manual crimp pliers
MH860 (M22520/7-01)
FT8
AF8 (M22520/1-01)
Following standard: EN 50306-2
Locator
MH86164G or TP1142
-
TP1142
Following standard: EN 50264-3-1
Selector set-up - Wire section
6
0.5 mm
2
4
0.5 mm
2
-
7
0.75 mm
2
4
0.75 mm
2
-
7
1 mm
2
5
1 mm
2
-
8
1.5 mm
2
5
1.5 mm
2
-
-
-
8
2.5 mm
2
Contact insertion
• Locate the right cavity and use a contact (male or female), to bore each individual grommet in its center.
Push the contact until mechanical stop.
• Check the correct contact retention by slightly pulling on the cable (no tools required).
• Check that each individual grommet is correctly plated on the back face of the connector, unless, put them properly.
Once all the contacts have been installed in the connector:
• Put the ty-rap in the designated cable support and tighten the ty-rap to gather the wires.
Cable support
5