Series HV
DC to DC Converters
Single and Dual Output
Hi Input Voltage (70170 VDC)
Hi Reliability Industrial Grade
Isolated 1000VDC
Fully Regulated up to 15 Watts
Short Circuit Protected
PICO's HV Series with wide input voltages are available in 32 different models. As switchers they
accommodate a 70 to 170 VDC input, and offer both single and dual, regulated output. These isolated
units will operate over a temperature range of 25º C to +70º C with no heat sink or electrical derating
required. They are excellent for applications where a rectified output from a 110 VDC source is available.
FEATURES
Excellent line regulation ± 1.0% (70
VDC 170 VDC)
Excellent load regulation, from 25%
to 100%, ± 2%
Continuous short circuit protection
Encapsulated semiconductors,
conservatively rated for maximum
reliability.
Isolation 100 megohms at 1000
VDC
Wide input 70 VDC to 170 VDC
TYPICAL CHARACTERISTICS:
Test conditions: 25º C ambient
Input Voltage: 70170 VDC
Converter frequency: 100 KHz to 1 MHz
Operating temperature: 20º C to +70º C
ambient
Storage temperature: 55º to +105º C
Output voltage temperature coefficient:
0.02%/º C
Isolation: 1000 VDC
Series HVA Single Output 3 Watts
No Terminal Strip Available
Max.
Output
Pico
Load
Voltage
Part
Current
(V DC)
Number
(mA)
HVA3.3S
3.3
600
Max.
Output
Power
(watts)
2
Load*
Output*
EFF.@*
Line*
Output* Regulation
Voltage
Full
Regulation
Voltage
25%
Ripple Price
Load
@ Full
Tolerance 100%
Typical (US
Typical
Load
(± %)
Load
(mv p
$)
(%)
(± %)
(± %)**
p)
63
2
2
1
50
88.48
HVA5S
HVA5.2S
HVA12S
HVA15S
HVA24S
HVA28S
5
5.2
12
15
24
28
600
577
250
200
125
105
3
3
3
3
3
3
65
65
67
67
68
68
2
2
2
2
2
2
2
2
2
2
2
2
0.5
1
0.5
0.5
0.5
0.5
50
50
50
50
50
50
88.48
88.48
88.48
88.48
88.48
88.48
*Measurements taken at nominal input voltage.
**10% minimum load required.
Terminal strip not available HVA
Series HVB Single Output 5 Watts
THVB Terminal Strip Model***
* * *
Max. Max.
Output
Pico
Load Output
Voltage
Part
Current Power
(V DC)
Number
(mA) (watts)
HVB3.3S
HVB5S
HVB5.2S
HVB12S
HVB15S
HVB24S
HVB28S
HVB48S
3.3
5
5.2
12
15
24
28
48
1000
1000
961
415
330
200
175
104
3.3
5
5
5
5
5
5
5
Load*
EFF.@*
Line* Output*
Output* Regulation
Full
Regulation Voltage * * *
Voltage
25%
Load
@ Full
Ripple Price
Tolerance 100%
Typical
Load
(mv p (US $)
(± %)
Load
(%)
(± %)
p)
(± %)**
67
70
70
73
73
74
74
74
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
1
1
1
1
1
1
1
1
50
50
50
50
50
50
50
150
101.30
101.30
101.30
101.30
101.30
101.30
101.30
101.30
*Measurements taken at nominal input voltage.
**10% minimum load required.
***For terminal strip models begin Part Number with letter T. Add $15.00 to prices shown
Series HVC Single Output 10 Watts
THVC Terminal Strip Available***
* * *
Max. Max.
Output
Pico
Load Output
Voltage
Part
Current Power
(V DC)
Number
(mA) (watts)
HVC3.3S
HVC5S
HVC5.2S
HVC12S
HVC15S
HVC24S
HVC28S
HVC48S
3.3
5
5.2
12
15
24
28
48
1515
1600
1538
830
660
415
355
208
5
8
8
10
10
10
10
10
Load*
Output*
EFF.@*
Line*
Output* Regulation
Voltage
Full
Regulation
* * *
Voltage
25%
Ripple
Load
@ Full
Price
Tolerance 100%
Typical
Typical
Load
(US $)
(± %)
Load
(mv p
(%)
(± %)
(± %)**
p)
67
69
69
75
77
77
77
74
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
1
1
1
1
1
1
1
1
50
50
50
50
50
50
50
200
114.12
114.12
114.12
114.12
114.12
114.12
114.12
114.12
*Measurements taken at nominal input voltage.
**10% minimum load required.
***For terminal strip models begin Part Number with letter T. Add $15.00 to prices shown
Series HVD Single Output 15 Watts
THVD Terminal Strip Model***
* * *
Max. Max.
Output
Pico
Load Output
Voltage
Part
Current Power
(V DC)
Number
(mA) (watts)
HVD3.3S
HVD5S
HVD5.2S
HVD12S
HVD15S
HVD24S
HVD28S
HVD48S
3.3
5
5.2
12
15
24
28
48
1818
2000
1923
1250
1000
625
535
312
6
10
10
15
15
15
15
15
Load*
Output*
EFF.@*
Line*
Output* Regulation
Voltage
Full
Regulation
* * *
Voltage
25%
Ripple
Load
@ Full
Price
Tolerance 100%
Typical
Typical
Load
(US $)
(± %)
Load
(mv p
(%)
(± %)
(± %)**
p)
68
70
70
75
76
76
76
74
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
1
1
1
1
1
1
1
1
50
50
50
50
50
50
50
200
126.95
126.95
126.95
126.95
126.95
126.95
126.95
126.95
*Measurements taken at nominal input voltage.
**10% minimum load required.
***For terminal strip models begin Part Number with letter T. Add $15.00 to prices shown
Series HVA Single
Output / 3 Watts
Series HVB Single
Output / 5 Watts
Larger Size Drawing
Larger Size Drawing and
Schematic
Series HVC Single
Output / 10 Watts
Series HVD Single
Output / 15 Watts
Larger Size Drawing and
Schematic
Larger Size Drawing and
Schematic
Series THVB Single
Output / 5 Watts
Measurements in inches
NOTE: The recommended torque for mounting screws is 3 to 5 InLbs
Larger Size Drawing and Schematic
Series THVC Single
Output / 10 Watts
Series THVD Single
Output / 15 Watts
Measurements in inches
NOTE: The recommended torque for mounting screws
is 3 to 5 InLbs
Measurements in inches
NOTE: The recommended torque for mounting screws
is 3 to 5 InLbs
Larger Size Drawing and Schematic
Larger Size Drawing and Schematic
Series HVA Dual Output 3 Watts
No Terminal Strip Available
Max.
Load
Output
Pico
Current
Voltage
Part
Per
(V DC)
Number
Out.
(mA)
HVA5D
HVA12D
HVA15D
± 5
± 12
± 15
300
125
100
Max.
Load*
Output*
EFF.@*
Line*
Output
Output* Regulation
Voltage
Full
Regulation
Power
Voltage
25%
Ripple
Load
@ Full
PRICE
Per
Tolerance 100%
Typical
Typical
Load
(US $)
Out
(± %)
Load
(mv p
(%)
(± %)
(watts)
(± %)**
p)
1.5
1.5
1.5
63
65
67
2
2
2
2
2
2
1
1
1
50
25
25
105.15
105.15
105.15
*Measurements taken at nominal input voltage.
**10% minimum load required.
Terminal strip not available HVA
Series HVB Dual Output 5 Watts
THVB Terminal Strip Model ***
Max.
* * *
Load
Output
Pico
Current
Voltage
Part
Per
(V DC)
Number
Out.
(mA)
HVB5D
HVB12D
HVB15D
± 5
± 12
± 15
500
200
165
Max.
Load*
Output*
EFF.@*
Line*
Output
Output* Regulation
Voltage
Full
Regulation
* * *
Power
Voltage
25%
Ripple
Load
@ Full
PRICE
Per
Tolerance 100%
Typical
Typical
Load
(US $)
Out
(± %)*
Load
(mv p
(%)
(± %)
(watts)
(± %)**
p)
2.5
2.5
2.5
70
73
73
2
2
2
2
2
2
1
1
1
50
25
25
117.97
117.97
117.97
*Measurements taken at nominal input voltage.
**10% minimum load required.
89.00***For terminal strip models begin Part Number with letter T. Add $15.00 to prices shown
Series HVC Dual Output 10 Watts
THVC Terminal Strip Model ***
Max.
* * *
Load
Output
Pico
Current
Voltage
Part
Per
(V DC)
Number
Out.
(mA)
HVC5D
HVC12D
HVC15D
± 5
± 12
± 15
800
415
335
Max.
Load*
Output*
EFF.@*
Line*
Output
Output* Regulation
Voltage
Full
Regulation
* * *
Power
Voltage
25%
Ripple
Load
@ Full
PRICE
Per
Tolerance 100%
Typical
Typical
Load
(US $)
Out
(± %)*
Load
(mv p
(%)
(± %)
(watts)
(± %)**
p)
4
5
5
68
75
76
2
2
2
2
2
2
1
1
1
50
25
25
130.79
130.79
130.79
*Measurements taken at nominal input voltage.
**10% minimum load required.
***For terminal strip models begin Part Number with letter T. Add $15.00 to prices shown
Series HVD Dual Output 15 Watts