POLYSNAP
®
POWER INLET MODULES
C14 IEC Fused Inlet/Sheet F IEC Outlet - Horizontal
HORIZONTAL MODULE ARRANGEMENT
Fused Inlet/Outlet
Combination with 2.8mm or
6.3mm tags
Filtered Inlet Option
Single or Twin Fused
BZH11/Z0000/00
How to Order
BZH xx / xxxxx / xx
Type of Inlet / Outlet
Single Fused C14 Power Inlet (cold condition) and
Sheet F Non-shuttered Power Outlet, 2.8 or 6.3mm
tabs:
11
= PF0011/63 + PX0695/63
12
= PF0011/28 + PX0695/28
Twin Fused C14 Power Inlet (cold condition) and
Sheet F Non-shuttered Power Outlet , 2.8 or 6.3mm
tabs:
13
= PF0033/63 + PX0695/63
14
= PF0033/28 + PX0695/28
Single Fused C14 Power Inlet (cold condition) and
Sheet F Shuttered Power Outlet, 2.8 or 6.3mm tabs:
19
= PF0011/63 + PX0783/63
20
= PF0011/28 + PX0783/28
Twin Fused C14 Power Inlet (cold condition) and
Sheet F Shuttered Power Outlet , 2.8 or 6.3mm
tabs:
21
= PF0033/63 + PX0783/63
22
= PF0033/28 + PX0783/28
Filtered or Non Filtered Inlet
Z0000 = Non Filtered
Axxxx = Standard
Bxxxx = Medical (Twin Fuse Version only)
Combination of Other Components
None
00
= None
For Filtered inlet use 6th to 9th characters from
filter ordering code see pages 127-129.
E.g. BZH11/A0620/00
Note: For technical details of individual components please see page 106
www.elektron-bulgin.com
121
IEC CONNECTORS