NMV Series
1 Watt 3 KV Isolation
Nominal
Output
Output
Efficiency
Model
Input Voltage
Voltage
Current
Number
Replace xx
5.0 V
200 mA
70%
NMVxx05SA
in part number
9.0 V
112 mA
80%
NMVxx09SA
with desired
12.0 V
84 mA
80%
NMVxx12SA
input:
15.0 V
67 mA
80%
NMVxx15SA
05 = 5 V
±5.0 V
±100 mA
70%
NMVxx05S
12 = 12 V
±9.0 V
±56 mA
80%
NMVxx09S
24 = 24 V
±12.0 V
±42 mA
80%
NMVxx12S
48 = 48 V
±15.0 V
±34 mA
80%
NMVxx15S
NOTE: Dual in line packages available; replace ‘S’ in part number with ‘D’.
Input
●
Input Range
●
Reflected Current
●
No Load Power Consumption
Output
●
Voltage Accuracy
●
Line Regulation (Vin ±10%)
●
Load Regulation
(10-100% full load)
●
Temperature Coefficient
●
Ripple and Noise
(20 MHz bandwidth)
●
Short Circuit Duration
General
●
Operating Temperature
●
Storage Temperature
●
Isolation (flash tested for 1 min)
●
Switching Frequency (full load)
●
Lead Temperature
±10% of nominal
40 mA pk-pk
560 mW typical
Typically within -7.5 to +2.5% of nominal
at full load
1.2%
15% max 5 V output models
10% max all other models
0.03%/°C max
80 mV pk-pk max
1s
-40 °C to +85 °C
-50 °C to +130 °C
3000 V DC
100 kHz
+300 °C/10 sec 1.5 mm from case
Weight : 2.11 g
www.xpplc.com
sales@xpplc.com
Rev 3.0