Power Supplies
AC Input
Single Output, General-Purpose
FEATURES
• Low profile, single output AC.100V input power supply.
• Compact open frame type.
• These low noise power supplies are FCC Class B standard com-
pliant.
• Low price.
PART NUMBERS AND RATINGS
Output voltage(V)
5
12
15
24
10W type
Current(A)
2
0.84
0.67
0.42
50W type
Current(A)
10
4.2
3.4
2.1
Part No.
JAK05-2R0
JAK12-R84
JAK15-R67
JAK24-R42
15W type
Current(A)
3
1.3
1
0.63
100W type
Current(A)
20
8.4
6.7
4.2
JAK Series
Part No.
JAK05-3R0
JAK12-1R3
JAK15-1R0
JAK24-R63
25W type
Current(A)
5
2.1
1.7
1.1
150W type
Current(A)
30
12.5
10
6.3
Part No.
JAK05-5R0
JAK12-2R1
JAK15-1R7
JAK24-1R1
Output voltage(V)
5
12
15
24
Part No.
JAK05-10R
JAK12-4R2
JAK15-3R4
JAK24-2R1
Part No.
JAK05-20R
JAK12-8R4
JAK15-6R7
JAK24-4R2
Part No.
JAK05-30R
JAK12-13R
JAK15-10R
JAK24-6R3
Specifications which provide more details for the proper and safe use of the described product are available upon request.
All specifications are subject to change without notice.
Power Supplies
AC Input
Single Output, General-Purpose
SPECIFICATIONS
10W TYPE
Part No.
Output voltage, current
∗
1
Maximum output power
Input requirements
Input voltage Eac
∗
2
Input frequency
Input current
Fuse rating
Surge current
Leakage current
Efficiency
Output characteristics
Output voltage
Voltage variable range
Maximum output current
∗
1
Overvoltage threshold
Overcurrent threshold
Input variation
Load variation
Voltage
Temperature
stability
variation
Drift
Dynamic load
Ripple noise Ep-p
Start up time
Hold up time
Accessory equipment
Operation indicator
Overvoltage protection
Overcurrent protection
Remote ON-OFF
Remote sensing
Output voltage external variable
function
Standards
Safety standards
Noise terminal voltage
Construction
External dimensions H
×
W
×
L
Weight
Mounting method
∗
1
Current
∗
2
JAK Series
W
V
Hz
A
A
A
mA
%
V
V
A
V
A
%
%
%
%
%/ms
mV
ms
ms
JAK05-2R0
5V • 2A
10
JAK12-R84
12V • 0.84A
10.1
JAK15-R67
15V • 0.67A
10.1
JAK24-R42
24V • 0.42A
10.1
85 to 132[Rating:100-120]
47 to 66[Single phase]
0.3max.[100V]
1.6[Internal]
40max.[100/120V]
0.5max.[100/120V]
70typ.
72typ.
5
12
4.5 to 5.5
10.8 to 13.2
2
0.84
5.6 to 6.9
13.4 to 15.7
2.1min.
0.9min.
2max.(1typ.)[Within the input voltage range]
2max.(1typ.)[10 to 100% load]
2max.(1typ.)[0 to +40°C]
73typ.
15
13.5 to 16.5
0.67
16.7 to 19
0.7min.
74typ.
24
21.6 to 26.4
0.42
26.7 to 30.5
0.44min.
Total variation ±3max.(±1typ.)
0.5max.(0.1typ.)[After input voltage ON for 30min to 8h]
±4max./1max.[50 to 100% sudden load change]
120max.
190max.
220max.
500max.[100V]
15min.(17typ.)[100V]
310max.
None
Voltage shielding type, recovers upon reset(interval approx. 40s).
Fixed current and voltage threshold type, automatic recovery, but overcurrent of 1s min. is shielded.
None
None
None
UL1950D3 recognized.
VCCI class 2, FCC class B compliant.
mm
g
19
×
60
×
77
65max.
1 side(Open frame)
rating(maximum output current) is determined for –10 to +40°C. Derating is required when used outside this temperature range.
When under load, output is cut off if the input voltage is below the minimum input voltage continuously for more than 1s.
Specifications which provide more details for the proper and safe use of the described product are available upon request.
All specifications are subject to change without notice.
Power Supplies
AC Input
Single Output, General-Purpose
SPECIFICATIONS
15W TYPE
Part No.
Output voltage, current
∗
1
Maximum output power
Input requirements
Input voltage Eac
∗
2
Input frequency
Input current
Fuse rating
Surge current
Leakage current
Efficiency
Output characteristics
Output voltage
Voltage variable range
Maximum output current
∗
1
Overvoltage threshold
Overcurrent threshold
Input variation
Load variation
Voltage
Temperature
stability
variation
Drift
Dynamic load
Ripple noise Ep-p
Start up time
Hold up time
Accessory equipment
Operation indicator
Overvoltage protection
Overcurrent protection
Remote ON-OFF
Remote sensing
Output voltage external variable
function
Standards
Safety standards
Noise terminal voltage
Construction
External dimensions H
×
W
×
L
Weight
Mounting method
∗
1
Current
∗
2
JAK Series
W
V
Hz
A
A
A
mA
%
V
V
A
V
A
%
%
%
%
%/ms
mV
ms
ms
JAK05-3R0
5V • 3A
15
JAK12-1R3
12V • 1.3A
15.6
JAK15-1R0
15V • 1A
15
JAK24-R63
24V • 0.63A
15.1
85 to 132[Rating:100-120]
47 to 66[Single phase]
0.4max.[100V]
1.6[Internal]
40max.[100/120V]
0.5max.[100/120V]
71typ.
72typ.
5
12
4.5 to 5.5
10.8 to 13.2
3
1.3
5.6 to 6.9
13.4 to 15.7
3.2min.
1.4min.
2max.(1typ.)[Within the input voltage range]
2max.(1typ.)[10 to 100% load]
2max.(1typ.)[0 to +40°C]
73typ.
15
13.5 to 16.5
1
16.7 to 19
1.05min.
74typ.
24
21.6 to 26.4
0.63
26.7 to 30.5
0.66min.
Total variation ±3max.(±1typ.)
0.5max.(0.1typ.)[After input voltage ON for 30min to 8h]
±4max./1max.[50 to 100% sudden load change]
120max.
190max.
220max.
500max.[100V]
15min.(17typ.)[100V]
310max.
None
Voltage shielding type, recovers upon reset(interval approx. 40s).
Fixed current and voltage threshold type, automatic recovery, but overcurrent of 1s min. is shielded.
None
None
None
UL1950D3 recognized.
VCCI class 2, FCC class B compliant.
mm
g
19
×
60
×
95
85max.
1 side(Open frame)
rating(maximum output current) is determined for –10 to +40°C. Derating is required when used outside this temperature range.
When under load, output is cut off if the input voltage is below the minimum input voltage continuously for more than 1s.
Specifications which provide more details for the proper and safe use of the described product are available upon request.
All specifications are subject to change without notice.
Power Supplies
AC Input
Single Output, General-Purpose
SPECIFICATIONS
25W TYPE
Part No.
Output voltage, current
∗
1
Maximum output power
Input requirements
Input voltage Eac
∗
2
Input frequency
Input current
Fuse rating
Surge current
Leakage current
Efficiency
Output characteristics
Output voltage
Voltage variable range
Maximum output current
∗
1
Overvoltage threshold
Overcurrent threshold
Input variation
Load variation
Voltage
Temperature
stability
variation
Drift
Dynamic load
Ripple noise Ep-p
Start up time
Hold up time
Accessory equipment
Operation indicator
Overvoltage protection
Overcurrent protection
Remote ON-OFF
Remote sensing
Output voltage external variable
function
Standards
Safety standards
Noise terminal voltage
Construction
External dimensions H
×
W
×
L
Weight
Mounting method
∗
1
Current
∗
2
JAK Series
W
V
Hz
A
A
A
mA
%
V
V
A
V
A
%
%
%
%
%/ms
mV
ms
ms
JAK05-5R0
5V • 5A
25
JAK12-2R1
12V • 2.1A
25.2
JAK15-1R7
15V • 1.7A
25.5
JAK24-1R1
24V • 1.1A
26.4
85 to 132[Rating:100-120]
47 to 66[Single phase]
0.65max.[100V]
1.6[Internal]
40max.[100/120V, 25°C cold start]
0.5max.[100/120V]
78typ.
79typ.
5
12
4.5 to 5.5
10.8 to 13.2
5
2.1
5.6 to 6.9
13.4 to 15.7
5.3min.
2.2min.
2max.(1typ.)[Within the input voltage range]
2max.(1typ.)[10 to 100% load]
2max.(1typ.)[0 to +40°C]
81typ.
15
13.5 to 16.5
1.7
16.7 to 19
1.8min.
82typ.
24
21.6 to 26.4
1.1
26.7 to 30.5
1.2min.
Total variation ±3max.(±1typ.)
0.5max.(0.1typ.)[After input voltage ON for 30min to 8h]
±4max./1max.[50 to 100% sudden load change]
120max.
190max.
220max.
500max.[100V]
15min.(17typ.)[100V]
310max.
None
Voltage shielding type, recovers upon reset(interval approx. 40s).
Fixed current and voltage threshold type, automatic recovery, but overcurrent of 1s min. is shielded.
None
None
None
UL1950D3 recognized.
VCCI class 2, FCC class B compliant.
mm
g
25
×
60
×
110
150max.
1 side(Open frame)
rating(maximum output current) is determined for –10 to +40°C. Derating is required when used outside this temperature range.
When under load, output is cut off if the input voltage is below the minimum input voltage continuously for more than 1s.
Specifications which provide more details for the proper and safe use of the described product are available upon request.
All specifications are subject to change without notice.
Power Supplies
AC Input
Single Output, General-Purpose
SPECIFICATIONS
50W TYPE
Part No.
Output voltage, current
∗
1
Maximum output power
Input requirements
Input voltage Eac
∗
2
Input frequency
Input current
Fuse rating
Surge current
Leakage current
Efficiency
Output characteristics
Output voltage
Voltage variable range
Maximum output current
∗
1
Overvoltage threshold
Overcurrent threshold
Input variation
Load variation
Temperature
Voltage
variation
stability
Drift
Dynamic load
Ripple noise Ep-p
Start up time
Hold up time
Accessory equipment
Operation indicator
Overvoltage protection
Overcurrent protection
Remote ON-OFF
Remote sensing
Output voltage external variable
function
Standards
Safety standards
Noise terminal voltage
Construction
External dimensions H
×
W
×
L
Weight
Mounting method
∗
1
Current
∗
2
JAK Series
W
V
Hz
A
A
A
mA
%
V
V
A
V
A
%
%
%
%
%/ms
mV
ms
ms
JAK05-10R
5V • 10A
50
JAK12-4R2
12V • 4.2A
50.4
JAK15-3R4
15V • 3.4A
51
JAK24-2R1
24V • 2.1A
50.4
85 to 132[Rating:100-120]
47 to 66[Single phase]
1.3max.[100V]
3.15[Internal]
40max.[100/120V, 25°C cold start]
0.5max.[100/120V]
77typ.
79typ.
5
12
4.5 to 5.5
10.8 to 13.2
10
4.2
5.6 to 6.9
13.4 to 15.7
10.5min.
4.4min.
2max.(1typ.)[Within the input voltage range]
2max.(1typ.)[10 to 100% load]
2max.(1typ.)[0 to +40°C]
79typ.
15
13.5 to 16.5
3.4
16.7 to 19
3.5min.
81typ.
24
21.6 to 26.4
2.1
26.7 to 30.5
2.2min.
Total variation ±3max.(±1typ.)
0.5max.(0.1typ.)[After input voltage ON for 30min to 8h]
±4max./1max.[50 to 100% sudden load change]
120max.
190max.
220max.
500max.[100V]
15min.(17typ.)[100V]
310max.
None
Voltage shielding type, recovers upon reset(interval approx. 40s).
Fixed current and voltage threshold type, automatic recovery, but overcurrent of 1s min. is shielded.
None
None
None
UL1950 recognized, Japan Electric/Electronic Products Control Law conformed.
VCCI class 2, FCC class B compliant.
mm
g
30
×
60
×
156
220max.
1 side(Open frame)
rating(maximum output current) is determined for –10 to +40°C. Derating is required when used outside this temperature range.
When under load, output is cut off if the input voltage is below the minimum input voltage continuously for more than 1s.
Specifications which provide more details for the proper and safe use of the described product are available upon request.
All specifications are subject to change without notice.