H
T-1
3
/
4
(5 mm) Diffused LED
Lamps
Technical Data
HLMP-3300 Series
HLMP-3400 Series
HLMP-3500 Series
HLMP-3762
HLMP-3862
HLMP-3962
HLMP-D400 Series
HLMP-D600
Features
• High Intensity
• Choice of 4 Bright Colors
High Efficiency Red
Orange
Yellow
High Performance Green
• Popular T-1
3
/
4
Diameter
Package
• Selected Minimum
Intensities
• Wide Viewing Angle
• General Purpose Leads
• Reliable and Rugged
• Available on Tape and Reel
Description
This family of T-1
3
/
4
tinted,
diffused LED lamps is widely used
in general purpose indicator
applications. Diffusants, tints, and
optical design are balanced to
yield superior light output and
wide viewing angles. Several
intensity choices are available in
each color for increased design
flexibility.
Selection Guide
Part Number
HLMP-
3300
3301
3762
D400
D401
3400
3401
3862
3502
3507
3962
D600
[1]
Application
General Purpose
High Ambient
Premium Lamp
General Purpose
High Ambient
General Purpose
High Ambient
Premium Lamp
General Purpose
High Ambient
Premium Lamp
General Purpose
Minimum Intensity
(mcd) at 10 mA
2.1
5.4
8.6
2.1
5.4
2.2
5.7
9.2
1.6
4.2
10.6
1.0
Emerald Green (GaP) 558 nm
Green (GaP) 565 nm
Yellow (GaAsP on GaP)
Orange (GaAsP on GaP)
Color (Material)
High Efficiency Red (GaAsP on GaP)
Note:
1. Please refer to Application Note 1061 for information comparing standard green and emerald green light output degradation.
1-94
5964-9294E
Package Dimensions
Optical/Electrical Characteristics at T
A
= 25
°
C
Symbol
I
V
Parameter
Luminous Intensity
Device
HLMP-
High Efficiency Red
3300
3301
3762
Orange
D400
D401
Yellow
3400
3401
3862
Green
3502
3507
3962
Emerald Green
D600
2θ
1
/
2
Included Angle
Between Half
Luminous Intensity
Points
Peak Wavelength
High Efficiency Red
Orange
Yellow
Green
Emerald Green
High Efficiency Red
Orange
Yellow
Green
Emerald Green
Min.
2.1
5.4
8.6
2.1
5.4
2.2
5.7
9.2
1.6
4.2
10.6
1.0
Typ. Max.
3.5
7.0
12.0
3.5
7.0
4.0
8.0
12.0
2.4
5.2
14.0
3.0
60
60
60
60
60
635
600
583
565
558
Deg.
I
F
= 10 mA
See Note 1
Units
mcd
Test
Conditions
I
F
= 10 mA
λ
PEAK
nm
Measurement
at Peak
1-95
Optical/Electrical Characteristics at T
A
= 25
°
C (cont.)
Symbol
∆λ
1/2
Parameter
Spectral Line Halfwidth
Device
HLMP-
HER/Orange
Yellow
Green
Emerald Green
High Efficiency Red
Orange
Yellow
Green
Emerald Green
High Efficiency Red
Orange
Yellow
Green
Emerald Green
High Efficiency Red
Orange
Yellow
Green
Emerald Green
All
HER/Orange
Yellow
Green
Emerald Green
All
High Efficiency Red
Orange
Yellow
Green
Emerald Green
5.0
–
–
145
380
500
595
656
Min.
Typ. Max.
40
36
28
24
626
602
585
569
560
90
280
90
500
560
11
4
15
18
3100
260
1.9
2.0
2.1
2.1
2.4
2.4
2.7
2.7
Units
nm
Test
Conditions
λ
d
Dominant Wavelength
nm
See Note 2
τ
s
Speed of Response
ns
C
Capacitance
pF
V
F
= 0;
f = 1 MHz
R
θ
J-PIN
Thermal Resistance
Forward Voltage
°C/W
V
Junction to
Cathode Lead
I
F
= 10 mA
V
F
V
R
η
V
Reverse Breakdown
Voltage
Luminous Efficacy
V
lumens
Watt
I
R
= 100
µA
See Note 3
Notes:
1.
θ
1
/
2
is the off-axis angle at which the luminous intensity is half the axial luminous intensity.
2. The dominant wavelength,
λ
d
, is derived from the CIE chromaticity diagram and represents the single wavelength which defines the
color of the device.
3. Radiant intensity, I
e
, in Watts/steradian, may be found from the equation I
e
= I
v
/η
v
, where I
v
is the luminous intensity in candelas and
η
v
is the luminous efficacy in lumens/Watt.
1-96
Absolute Maximum Ratings at T
A
= 25
°
C
Parameter
Peak Forward Current
Average Forward Current
[1]
DC Current
[2]
Power Dissipation
[3]
Reverse Voltage (I
R
= 100
µA)
Transient Forward Current
[4]
(10
µsec
Pulse)
LED Junction Temperature
Operating Temperature Range
Storage Temperature Range
Lead Soldering Temperature
[1.6 mm (0.063 in.) from body]
HER/Orange
90
25
30
135
5
500
110
-55 to +100
Yellow
60
20
20
85
5
500
110
-55 to +100
Green/
Emerald Green
90
25
30
135
5
500
110
-20 to +100
-55 to +100
260°C for 5 seconds
Units
mA
mA
mA
mW
V
mA
°C
°C
Notes:
1. See Figure 5 (Red/Orange), 10 (Yellow), or 15 (Green) to establish pulsed operating conditions.
2. For Red, Orange and Green series derate linearly from 50°C at 0.5 mA/°C. For Yellow series derate linearly from 50°C at 0.2 mA/°C.
3. 1.8 mW/°C. For Yellow series derate power linearly from 50°C at 1.6 mW/°C.
4. The transient peak current is the maximum non-recurring peak current that can be applied to the device without damaging the LED
die and wirebond. It is not recommended that the device be operated at peak currents beyond the peak forward current listed in the
Absolute Maximum Ratings.
1.0
EMERALD GREEN
ORANGE
T
A
= 25° C
RELATIVE INTENSITY
GREEN
HIGH EFFICIENCY RED
0.5
YELLOW
0
500
550
600
WAVELENGTH – nm
650
700
750
Figure 1. Relative Intensity vs. Wavelength.
1-97
T-1
3
/
4
High Efficiency Red, Orange Diffused Lamps
Figure 2. Forward Current vs.
Forward Voltage Characteristics.
Figure 3. Relative Luminous Intensity
vs. DC Forward Current.
Figure 4. Relative Efficiency
(Luminous Intensity per Unit Current)
vs. Peak LED Current.
Figure 5. Maximum Tolerable Peak
Current vs. Pulse Duration. (I
DC
MAX
as per MAX Ratings).
Figure 6. Relative Luminous Intensity vs. Angular Displacement.
1-98