MICRO-PAC PLUS™
Low Profile Power Inductors
(Surface Mount)
Description
• High performance, low profile, surface mount power
inductors with a molybdenum permalloy core
• Small footprint and closed magnetic field construction
ensure low EMI
• Low DCR and high efficiency
• Frequency range up to 500kHz
• RoHS compliant (-R option)
Applications
• PC cards, cellular telephones, pagers, and disk drives
• GPS systems
Environmental Data
• Storage temperature range: -40C to +125C
• Operating ambient temperature range: -40C to +85C
(range is application specific).
• Infrared reflow temperature: +240°C for 30 seconds
maximum
Part
Number
MP2A-R47
MP2A-R68
MP2A-1R0
MP2A-1R5
MP2A-2R2
MP2A-3R3
MP2A-4R7
MP2A-6R8
MP2A-8R2
MP2A-100
MP2A-150
MP2A-220
MP2A-330
MP2A-470
MP2A-680
MP2A-820
MP2A-101
Inductance
µH
(rated)
0.47
0.68
1.00
1.50
2.20
3.30
4.70
6.80
8.20
10.00
15.00
22.00
33.00
47.00
68.00
82.00
100.00
OCL
(1)
µH±20%
0.47
0.68
1.21
1.54
2.30
3.21
4.86
6.85
8.54
10.02
15.18
21.40
32.74
46.48
68.53
81.15
99.65
DCR
(2)
typ.
Ω
0.024
0.027
0.067
0.073
0.086
0.098
0.117
0.136
0.167
0.179
0.217
0.311
0.476
0.727
1.108
1.463
2.015
Packaging
• Supplied in tape and reel packaging, 3900 per reel
I
RMS
(3)
Amperes
3.52
3.31
2.11
2.02
1.87
1.75
1.60
1.49
1.34
1.29
1.18
0.98
0.79
0.64
0.52
0.45
0.39
I
SAT
(4)
Amperes
5.80
4.83
3.63
3.22
2.64
2.23
1.81
1.53
1.54
1.42
1.16
0.97
0.79
0.66
0.54
0.50
0.45
Volt
(5)
µsec
1.20
1.27
2.00
2.09
2.26
2.42
2.64
2.84
3.15
3.26
3.59
4.30
5.32
6.57
8.11
9.32
10.94
Notes:
(1) Open Circuit Inductance Test Parameters: 100 kHz, .25Vrms, 0.0Adc.
(2) DCR limits 20°C.
(3) RMS current for an approximate
∆T
of 40°C without core loss. It is
recommended that the temperature of the part not exceed 125°C.
(4) Peak current for approximately 30% rolloff at 20°C.
(5) Applied Volt-Time product (V-µS) across the inductor. This value
represents the applied V-µS at 300KHz necessary to generate a core
loss equal to 10% of the total losses for 40°C temperature rise.
Option Code
-R
OPTION CODE
Description
RoHS compliant version
Mechanical Diagrams
TOP VIEW
1
SIDE VIEW
1.05
PCB PAD LAYOUT
SCHEMATIC
1
7.50
5.88
YWW
XXX
7.5
MAX
5.2
MAX
1.8
MAX
5.40
2
2.00
2
Dimensions in Millimeters.
Specifications are subject to change without notice.
yww = Date Code
xxx = Inductance value per family chart
®
MICRO-PAC PLUS™
Low Profile Power Inductors
(Surface Mount)
Rolloff
100%
90%
80%
70%
60%
50%
40%
30%
20%
10%
0%
0%
% of L initial
10% 20% 30% 40% 50% 60% 70% 80% 90% 100% 110% 120% 130% 140% 150% 160%
% of I sat
Core Loss
I
RMS
DERATING WITH CORE LOSS
0
% of Losses from Irms (maximum)
20
40
50
60
70
80
0K
40
Hz
0K
Hz
30
0K
Hz
20
0K
Hz
100
90
92
94
95
96
97
98
99
10
20
30
40
50
60
80
200
300
400 500 600
800 1000
% of Applied Volt-µ-Seconds
Packaging Information for MICRO-PAC™ & MICRO-PAC™ PLUS
50
10
0K
Hz
ACTUAL SIZE
MICRO-PAC PLUS
Ao=5.6mm
A1=2.3mm
Bo=8.5mm
B1=6.3mm
Ko=2.1mm
Parts packaged on 13" Diameter reel,
3,900 parts per reel.
PM-4112 7/05
© Cooper Electronic
Technologies 2005
Visit us on the Web at www.cooperET.com
3601 Quantum Boulevard Boynton Beach, Florida 33426-8638
Tel: +1-561-752-5000 Toll Free: +1-888-414-2645 Fax: +1-561-742-1178
This bulletin is intended to present product design solutions and technical information that will help the end user with design applications. Cooper Electronic
Technologies reserves the right, without notice, to change design or construction of any products and to discontinue or limit distribution of any products. Cooper
Electronic Technologies also reserves the right to change or update, without notice, any technical information contained in this bulletin. Once a product has been
selected, it should be tested by the user in all possible applications.
Life Support Policy: Cooper Electronic Technologies does not authorize the use of any of its products for use in life support devices or systems without the
express written approval of an officer of the Company. Life support systems are devices which support or sustain life, and whose failure to perform, when
properly used in accordance with instructions for use provided in the labeling, can be reasonably expected to result in significant injury to the user.