NHG RELAYS
NG4U
R
22.5 12.5 19
Features
R2133923
C
US
E160644
Can be welded directly onto PCB.
Used in household appliances like air conditioning , heater and instruments etc.
Ordering Information
NG4U C S 10 DC12V
1
2
3
4
5
4 Contact current 5A,10A
5 Coil rated voltage(V) DC:6,12,24
1 Part number NG4U
2 Contact arrangement A:1A C:1C
3 Enclosure S:Sealed type Z:Dust cover
Contact Data
Contact Arrangement
Contact Material
Contact Rating (resistive)
Max. Switching Power
Max. Switching Voltage
Contact Resistance or Voltage drop
Operational
life
Electrical
Mechanical
1A (SPSTNO)
AgCdO AgSnO
2
5A,10A/125VAC,28VDC
280W 1250VA
30VDC 220VAC
50m
10
5
10
7
Max. Switching Current:10A
Item 3.12 of IEC255-7
Item 3.30 of IEC255-7
Item 3.31 of IEC255-7
1C (SPDT(B-M))
Coil Parameter
Coil voltage
VDC
Rated
006-360
012-360
024-360
6
12
24
Max.
7.8
15.6
31.2
100
400
1600
Coil
resistance
10%
Pickup
voltage
VDC(max)
(75% of rated
voltage)
Release
voltage
VDC(min)
(10% of rated
voltage)
Coil power
consumption
W
Operate
Time
ms
Release
Time
ms
Dash
numbers
4.2
8.4
16.8
0.6
1.2
2.4
0.36
10
5
CAUTION:
1.The use of any coil voltage less than the rated coil voltage will compromise the operation of the relay.
2.Pickup and release voltage are for test purposes only and are not to be used as design criteria.