General Purpose Relays
Force Guided Relays
Force Guided Relay SR4 D/M
n
n
SCHRACK
4 pole relay with force guided contacts according to EN EN61810-3
(formerly EN50205)
Compact design and space efficient
Typical applications
Emergency shut-off, press control, machine control, elevator and escalator
control, safety relays
F0244-C
Z
Approvals
VDE Cert. No. 40005334, UL E214025, TUV 968/EL 230,
CCC 2019010303217075
Technical data of approved types on request
Coil data
Coil voltage range
Coil versions, DC-coil
Coil
Rated
Operate
code
voltage
voltage
VDC
VDC
005
5
3.8
006
6
4.5
009
9
6.8
012
12
9.0
015
15
11.3
018
18
13.5
021
21
16.0
024
24
18.0
036
36
27.0
040
40
30.0
048
48
36.0
060
60
45.0
085
85
63.8
110
110
83.0
Release
voltage
VDC
0.5
0.6
0.9
1.2
1.5
1.8
2.1
2.4
3.6
4.0
4.8
6.0
8.5
11.0
5 to 110VDC
Coil
resistance
Ω±10%
31
45
101
180
281
405
551
720
1620
2000
2880
4500
9031
15125
Rated coil
power
mW
806
800
802
800
801
800
800
800
800
800
800
800
800
800
Contact Data
3 form A + 1 form B contacts
3 NO + 1 NC
2 form A + 2 form B contacts
2 NO + 2 NC
Rated voltage
250VAC
Max. switching voltage
400VAC
Rated current
8A
Contact material
AgSnO
2
Contact style
single contact, force guided
type A according to EN61810-3
(formerly EN50205)
Min. recommended contact load
5V/10mA
Initial contact resistance
≤100mΩ at 1A, 24VDC
≤20Ω at 10mA, 5VDC
Frequency of operation, with/without load
6/150min
-1
Contact ratings
IEC60947-5-1,
AC15-3A
on 1 form A (NO) contact
DC13-3A
Contact arrangement
All figures are given for coil without pre-energization, at ambient temperature +23°C.
Mechanical endurance
10x10
6
operations
03-2020, Rev. 0320
www.te.com
© 2015 Tyco Electronics Corporation,
a TE Connectivity Ltd. company
Datasheets and product specification
according to IEC 61810-1 and to be used
only together with the ‘Definitions’ section.
Datasheets and product data is subject to the
terms of the disclaimer and all chapters of
the ‘Definitions’ section, available at
http://relays.te.com/definitions
Datasheets, product data, ‘Definitions’ sec-
tion, application notes and all specifications
are subject to change.
1
General Purpose Relays
Force Guided Relays
Force Guided Relay SR4 D/M
(Continued)
Insulation Data
PCB layout / terminal assignment
Bottom view on solder pins
SCHRACK
Initial dielectric strength
between open contacts
1500Vrms
between contact and coil
4000Vrms
between adjacent contacts
2500Vrms
Clearance/creepage
between open contacts
microdisconnection
between contact and coil
≥10/10mm
between adjacent contacts
≥3/3.5mm
Insulation to EN 50178, type of insulation
between contact and coil
reinforced
between adjacent contacts
basic
S0413-BC
Other Data
Material compliance: EU RoHS/ELV, China RoHS, REACH, Halogen content
refer to the Product Compliance Support Center at
www.te.com/customersupport/rohssupportcenter
Ambient temperature
-25 to 70°C
Category of environmental Protection
IEC 61 810
RTIII
Weight
30g
Resistance to soldering heat THT
IEC 60068-2-20
260°C/5s
Packaging/unit
tube/10 pcs.
2 form A + 2 form B, 2 NO + 2 NC contacts
S0413-BB
3 form A + 1 form B, 3 NO + 1 NC contacts
For more detailed information see product specification 2158002
Dimensions
S0413-BA
S0412-BH
Product code structure
Type
SR4
Relay with force guided contacts SR4
Contact arrangement
D
2 form A + 2 form B contacts (2 NO + 2 NC)
M
3 form A + 1 form B contacts (3 NO + 1 NC)
Contact material
4
AgSnO
2
Coil
Coil code: please refer to coil versions table (e.g. 012=12VDC)
Other types on request
Typical product code
SR4
D
4
012
2
03-2020, Rev. 0320
www.te.com
© 2015 Tyco Electronics Corporation,
a TE Connectivity Ltd. company
Datasheets and product specification
according to IEC 61810-1 and to be used
only together with the ‘Definitions’ section.
Datasheets and product data is subject to the
terms of the disclaimer and all chapters of
the ‘Definitions’ section, available at
http://relays.te.com/definitions
Datasheets, product data, ‘Definitions’ sec-
tion, application notes and all specifications
are subject to change.
General Purpose Relays
Force Guided Relays
Force Guided Relay SR4 D/M
(Continued)
Product code
SR4D4005
SR4D4006
SR4D4009
SR4D4012
SR4D4018
SR4D4021
SR4D4024
SR4D4036
SR4D4040
SR4D4048
SR4D4060
SR4D4085
SR4D4110
SR4M4005
SR4M4006
SR4M4009
SR4M4012
SR4M4018
SR4M4021
SR4M4024
SR4M4036
SR4M4040
SR4M4048
SR4M4060
SR4M4085
SR4M4110
SCHRACK
4 pole
relay with
force guided contacts
Type
Contact arrangement
2 form A + 2 form B,
2 NO + 2 NC
contacts
Contact material
AgSnO
2
3 form A + 1 form B,
3 NO + 1 NC
contacts
5VDC
6VDC
9VDC
12VDC
18VDC
21VDC
24VDC
36VDC
40VDC
48VDC
60VDC
85VDC
110VDC
5VDC
6VDC
9VDC
12VDC
18VDC
21VDC
24VDC
36VDC
40VDC
48VDC
60VDC
85VDC
110VDC
Coil
Part number
7-1415054-1
8-1415054-1
9-1415054-1
1415055-1
1-1415055-1
2-1415055-1
3-1415055-1
4-1415055-1
5-1415055-1
6-1415055-1
7-1415055-1
8-1415055-1
9-1415055-1
5-1415053-1
6-1415053-1
7-1415053-1
8-1415053-1
9-1415053-1
1415054-1
4-1415053-1
1-1415054-1
2-1415054-1
3-1415054-1
4-1415054-1
5-1415054-1
6-1415054-1
03-2020, Rev. 0320
www.te.com
© 2015 Tyco Electronics Corporation,
a TE Connectivity Ltd. company
Datasheets and product specification
according to IEC 61810-1 and to be used
only together with the ‘Definitions’ section.
Datasheets and product data is subject to the
terms of the disclaimer and all chapters of
the ‘Definitions’ section, available at
http://relays.te.com/definitions
Datasheets, product data, ‘Definitions’ sec-
tion, application notes and all specifications
are subject to change.
3