All numerical values are in metric units [with U.S. customary units in brackets]. Dimensions are in millimeters [and
inches]. Unless otherwise specified, dimensions have a tolerance of +0.13 [+.005] and angles have a tolerance of +2_.
Figures and illustrations are for identification only and are not drawn to scale.
1. INTRODUCTION
This specification covers the requirements for application of the AMP--LATCH Novo line of receptacle
connectors. The receptacles are available in sizes of 10, 14, 16, 20, 24, 26, 30, 34, 40, 50, 60, and 64
positions.
The contacts housed in these receptacles are of the insulation displacement connection (IDC) type. They
accept mating headers or other pin connectors having 0.64 [.025]--square pins or 0.64 [.025]--diameter round
pins 6.1 [.240] nominal length. Intermateability limitations and available polarization features are detailed in
Paragraph 3.2.
When corresponding with TE Connectivity representatives, use the terminology provided in this specification to
facilitate your inquiry for information. Basic terms and features of the connectors and contacts are provided in
Figure 1. Accessories and their identifying features are described in Paragraph 3.4 and shown in Figure 5.
Typical Cover
Position 1 Index
Slot on This End
Typical Novo
Contact
With
Dual Polarization
No Polarization Bar on
This End of 10-- Position
Receptacles
With Military
Polarization
With Center and
Military Polarization
End Wall
No Polarization Slot on
This End of 10-- and
14-- Position Receptacles
Figure 1
E2011
Tyco Electronics Corporation, a TE Connectivity Ltd. Company
All Rights Reserved
*Trademark
TOOLING ASSISTANCE CENTER 1--800--722--1111
PRODUCT INFORMATION 1--800--522--6752
No Polarization Slot on
This End of 10-- and
14-- Position Receptacles
This controlled document is subject to change.
For latest revision and Regional Customer Service,
visit our website at
www.te.com
1
of 9
LOC B
TE Connectivity, TE connectivity (logo), and TE (logo) are trademarks. Other logos, product and/or Company names may be trademarks of their respective owners.
114- 40005
2. REFERENCE MATERIAL
2.1. Revision Summary
This paragraph is reserved for a revision summary of changes and additions made to this specification. The
following changes were made for this revision.
S
Updated document to corporate requirements.
2.2. Customer Assistance
Reference Part Number 746285 and Product Code 5754 are representative numbers of the AMP--LATCH line
of receptacle connectors. Use of these numbers will identify the product line and expedite your inquiries
through a service network established to help you obtain product and tooling information. Such information can
be obtained through a local TE Representative (Field Sales Engineer, Field Applications Engineer, etc.) or,
after purchase, by calling the Product Information number on the bottom of page 1.
2.3. Drawings
Customer Drawings for each product part number are available from the service network. The information
contained in Customer Drawings takes priority if there is a conflict with this specification or with any technical
documentation supplied by TE.
2.4. Specifications
Product Specification108--40000 for AMP--LATCH Novo and Novo Stackable Receptacles covers test data and
performance requirements.
2.5. Instructional Material
The following list includes available instruction sheets (408--series) that provide assembly procedures for
product, operation, maintenance and repair of tooling, as well as setup and operation procedures of
applicators; and customer manuals (409--series) that provide setup, operation, and maintenance of machines.
Document Number
408--6732
408--7763
408--7777
408--9828
408--9831
409--5725
409--5794
Document Title
Pneumatic Auto--Cycle Unit
Pneumatic Applicator Frame Assembly
Manual Arbor Frame Assembly
AMP--LATCH Universal Tooling Kit
AMP--LATCH Receptacle Connector--Specific Kits
R--CAM 2A Cable Terminating Machine 760700--6
R--CAM 3A Cable Terminating Machine 761900--[ ]
3. REQUIREMENTS
3.1. Storage
A. Ultraviolet Light
Prolonged exposure to ultraviolet light may deteriorate the chemical composition used in the housing
material.
B. Shelf Life
Each connector is packaged and shipped in an individual antistatic tube container. To prevent damage to
the housings and contacts, the connectors should remain in the container until ready for installation. Also,
to prevent possible storage contamination, the connectors should be used on a first in, first out basis.
C. Chemical Exposure
Do not store product near any of the following chemicals as they may cause stress corrosion.
Alkalies
Amines
NOTE
Ammonia
Carbonates
Citrates
Nitrites
Phosphates Citrates
Sulfides Nitrites
Sulfur Compounds
Tartrates
i
2
of 9
Where the above environmental conditions exist, phosphor--bronze contacts are recommended instead of brass if
available.
Rev
H
114- 40005
3.2. Cable Selection and Preparation
The IDC contacts in AMP--LATCH receptacles are designed to accept PVC--insulated cable wires with 26 or 28
AWG conductors. Insulation materials other than standard PVC must be submitted to TE Engineering for
evaluation before use. The types of cables that can be used are shown in Figure 2. Also shown is the initial cut
to be made, regardless of the cable type, using a guillotine--type cutting tool. Contact your TE representative
for current tool recommendations for cutting and notching of cables.
Initial Cable Cut
(For All Cable Types)
- A--
0.25 [.010]
A
CABLE
TYPE
Standard Planar
or Ribbon
Woven (Discrete Wire)
All Shielded Types
Jacketed Flat
Twisted--Pair FLat
CONDUCTOR
SIZE (AWG)
26
28
28
28
28
28
TYPE
Stranded or Solid
Stranded or Solid
Stranded or Solid
Stranded or Solid
Stranded
Figure 2 (cont’d)
“A”
0.94 [.037]
0 94 [ 037]
0.79 [.031]
0.81 [.032]
0.86 [.034]
1.09 [.043]
DIMENSION
“B”
(Total Number
of Conductors Minus 1)
x 1.27 [.050]
Rev
H
3
of 9
114- 40005
B+(See Note 1)
Cable Types
Standard Planar Cable
B+(See Note 1)
0.64+0.18
[.025+.007]
(Typ)
1.27+0.08
[.050+.003]
Ribbon Cable
A+0.13
[+.005]
0.64+0.18
[.025+.007]
(Typ)
1.27+0.08
[.050+.003]
A+0.13
[+.005]
Jacketed Flat Cable
Woven Cable
(Discrete Wire)
B+(See Note 1)
B+(See Note 1)
43.18
[1.70]
(Min)
0.64+0.18
[.025+.007]
(Typ)
A+0.13
[+.005]
12.7
[.500]
(Min)
1.27+0.08
[.050+.003]
1.27+0.08
[.050+.003]
A+0.13
[+.005]
0.64+0.18
[.025+.007]
(Typ)
(See Note 2)
B+(See Note 1)
A+0.13
[+.005]
60.32
[2.375]
11.18
[.44]
(Min)
0.64+0.18
[.025+.007]
(Typ)
1.27+0.08
[.050+.003]
44.45
[1.750]
Shielded Cable
Twisted- Pair Flat Cable
A+0.13
[+.005]
Notes:
1.Cumulative tolerance for cables with 1--34 conductors is +0.25 [+.010];
for cables with 40--64 conductors is +0.38 [+.015].
2.Ground plane and shielded cable must be notched as shown.
Figure 2 (end)
4
of 9
Rev
H
114- 40005
3.3. Product Selection
The specific acceptable pin length range for AMP--LATCH Novo Receptacles is
4.44-- 6.22 [.175-- .245].
Figure 3 shows relationships between available receptacles and the connectors that will mate with them.
MATING
CONNECTOR TYPES
Pin Connector with or without Mounting Ears
Pin Connector with or without Mounting Ears
and with Detent Windows
Bulkhead Pin Connector
Universal Ejection Style Pin Header
Military Ejection Style Header
Low--Profile Pin Header
High Temperature Universal
Ejection Style Pin Header
Universal Ejection Style Pinless Header
Stacked Headers
AMPMODU* HeadersU
POLARIZATION OPTIONS
MILITARY
X
X
X
X
X
X
X
X
X
X
CENTER AND MILITARY
X
X
------
X
X
X
X
X
X
------
DUAL
X
X
X
X
------
X
X
X
X
X
U
Only headers that have a 3.81 [.150] end dimension will mate.
Figure 3
A.
Polarization and Strain Relief
Polarization has been designed into the housings of Novo receptacles.
B.
Military, Center, and Dual Polarization
Receptacles with military polarization can be used in all header and plug connectors. Those with a
combination of military and center polarization, and those with dual polarization can only be used with
header or plug connectors that have the respective type of center or dual polarization.
C.
Receptacle Cover Options
Covers are designed for either feed--through or end--of--line applications.
3.4. Terminated Receptacle Requirements
Prepared cable shall be terminated according to the procedures given in the applicable tooling instructions.
See Paragraph 2.3, for details on tooling options and instructional materials. Figure 4 shows criteria for
acceptable terminations.
NOTE
Reasonable care should be taken by tooling operators to provide undamaged terminations. An improper termination in
any of the IDC contacts will be reason to discard the entire receptacle. Contacts are designed for one--time
termination, and cannot be replaced, repaired, or re--used.
DWORD WINAPI ReadPortThread(LPVOID lpvoid)
{
BYTE Byte;
DWORD dwCommModemStatus,
dwBytesTransferred;
CString tempStr;
// Specify a set of events to be m ......
中国 北京—— Analog Devices, Inc. (纽约证券交易所代码 : ADI ),全球领先的高性能信号处理解决方案供应商,最新推出两款模拟输出驱动器—— AD5750 和 AD5751 ,能显著提高过程控制应用的效率和可靠性,包括那些在高恒流电压和高温条件下工作的过程控制应用。这两款器件基于 ADI 公司的 iCMOS ™工业工艺技术,输出驱动器的精度...[详细]