2171108-1 | TE620PF-WT02: CMP F/UTP 4/23 C6 1K'
Category 6 F/UTP Cable, plenum, white jacket, 4 pair count, 1000 ft (305
m) length, reel
OBSOLETE
Replaced By
UN874022704/10
CS34P Category 6 F/UTP Cable, plenum, white jacket, 4 pair count, 1000 ft (305 m) length,
CS34P WHT C6 4/23 F/UTP RL 1KFT reel
Product Classification
Portfolio
Product Type
Regional Availability
NETCONNECT®
Twisted pair cable
Asia | Australia/New Zealand | EMEA | Latin America | North America
Cross Section Drawing
Construction Materials
Jacket Material
Conductor Material
Drain Wire Material
Insulation Material
Separator Material
PVC
Bare copper
Tinned copper
FEP
FEP
page 1 of 4
March 25, 2019
©2019 CommScope, Inc. All rights reserved. All trademarks identified by ® or ™ are registered trademarks,
respectively, of CommScope.All specifications are subject to change without notice. See www.commscope.com for the
most current information. Revised: January 21, 2019
2171108-1 | TE620PF-WT02: CMP F/UTP 4/23 C6 1K'
Shield (Tape) Material
Aluminum/Polyester
Dimensions
Cable Length
Cable Weight
Diameter Over Jacket, nominal
Jacket Thickness
305 m | 1000 ft
38.20 lb/ft
6.934 mm | 0.273 in
0.457 mm | 0.018 in
Electrical Specifications
ANSI/TIA Category
Characteristic Impedance
dc Resistance Unbalance, maximum
dc Resistance, maximum
Delay Skew, maximum
Mutual Capacitance
Operating Frequency, maximum
Transmission Standards
Safety Voltage Rating
Dielectric Strength, minimum
Note
6
100 ohm
5%
9.38 ohms/100 m
45 ns
5.6 nF/100 m @ 1 kHz
250 MHz
ANSI/TIA-568-C.2 | CENELEC EN 50288-6-1 | ISO/IEC 11801 Class E
300 V
1500 Vac | 2500 Vdc
All electrical transmission tests include swept frequency measurements
Nominal Velocity of Propagation (NVP)
71 %
Environmental Specifications
Environmental Space
Flame Test Method
Installation Temperature
Operating Temperature
Plenum
CMP | NFPA 262
0 °C to +60 °C (+32 °F to +140 °F)
-20 °C to +60 °C (-4 °F to +140 °F)
General Specifications
Cable Type
Packaging Type
Pairs, quantity
Cable Component Type
Jacket Color
Product Number
Conductor Gauge, singles
Conductor Type, singles
Conductors, quantity
Drain Wire Gauge
F/UTP (shielded)
Reel
4
Horizontal
White
620PF
23 AWG
Solid
8
24 AWG
page 2 of 4
March 25, 2019
©2019 CommScope, Inc. All rights reserved. All trademarks identified by ® or ™ are registered trademarks,
respectively, of CommScope.All specifications are subject to change without notice. See www.commscope.com for the
most current information. Revised: January 21, 2019
2171108-1 | TE620PF-WT02: CMP F/UTP 4/23 C6 1K'
Drain Wire Type
Separator Type
Solid
Isolator
Mechanical Specifications
Pulling Tension, maximum
11 kg | 25 lb
Regulatory Compliance/Certifications
Agency
RoHS 2011/65/EU
ISO 9001:2015
Classification
Compliant
Designed, manufactured and/or distributed under this quality management system
page 3 of 4
March 25, 2019
©2019 CommScope, Inc. All rights reserved. All trademarks identified by ® or ™ are registered trademarks,
respectively, of CommScope.All specifications are subject to change without notice. See www.commscope.com for the
most current information. Revised: January 21, 2019
2171108-1 | TE620PF-WT02: CMP F/UTP 4/23 C6 1K'
Electrical Performance
Std
IL
NEXT
ACR
PSNEXT
PSACR
ACRF
PSACRF
RL
TCL
ELTCTL
Freq.
MHz
1
4
8
10
16
20
25
31.25
62.5
100
155
200
250
Refers to the standard value listed under Transmission Standards in the Electrical Specifications above
Insertion Loss (dB/100m)
Near End Crosstalk (dB/100m)
Attenuation to Crosstalk Ratio (dB/100m)
Power Sum Near End Crosstalk (db/100m)
Power Sum Attenuation to Crosstalk Ratio (dB/100m)
Attenuation to Crosstalk Ratio - Far End (dB/100m)
Power Sum Attenuation to Crosstalk Ratio – Far End (dB/100m)
Return Loss (dB)
Transverse Conversion Loss (dB/100m)
Equal Level Transverse Conversion Transfer Loss (dB/100m)
IL
Std
2.0
3.8
5.3
6.0
7.6
8.5
9.5
10.7
15.4
19.8
25.2
29.0
32.8
NEXT
Std
74.3
65.3
60.8
59.3
56.2
54.8
53.3
51.9
47.4
44.3
41.4
39.8
38.3
ACR
Std
72.3
61.5
55.4
53.3
48.7
46.3
43.8
41.2
32.0
24.5
16.3
10.8
5.5
PSNEXT
Std
72.3
63.3
58.8
57.3
54.2
52.8
51.3
49.9
45.4
42.3
39.4
37.8
36.3
PSACR
Std
70.3
59.5
53.4
51.3
46.7
44.3
41.8
39.2
30.0
22.5
14.3
8.8
3.5
ACRF
Std
67.8
55.8
49.7
47.8
43.7
41.8
39.8
37.9
31.9
27.8
24.0
21.8
19.8
PSACRF
Std
64.8
52.8
46.7
44.8
40.7
38.8
36.8
34.9
28.9
24.8
21.0
18.8
16.8
RL
Std
20.0
23.0
24.5
25.0
25.0
25.0
24.3
23.6
21.5
20.1
18.8
18.0
17.3
TCL
Std
40.0
40.0
40.0
40.0
38.0
37.0
36.0
35.1
32.0
30.0
28.1
27.0
26.0
ELTCTL
Std
35.0
23.0
16.9
15.0
10.9
9.0
7.0