LDB60U60W4
600V 60A Ultra-Fast Recovery Diode
Description
FRED
from
Lonten
utilizes
advanced
processing
techniques to achieve ultra-fast recovery times and
higher forward current. Its soft recovery characteristics
and high reliability suit for wide industrial applications
.
Product Summary
600V
60A
FRED
TO-247 Pin Configuration
Features
Ultra-fast Recovery Time
Soft Recovery Characteristics
Low Recovery Loss
Low Forward Voltage
High Surge Current Capability
Low Leakage Current
1
2
Applications
Freewheeling, Snubber, Clamp
Inversion Welder
PFC
Plating Power Supply
Ultrasonic Cleaner and Welder
Converter & Chopper
UPS
Pb
Absolute Maximum Ratings
Parameter
Maximum D.C. Reverse Voltage
Maximum Repetitive Reverse Voltage
Average Forward Current( Tc = 110℃)
RMS Forward Current( Tc = 110℃)
Non-Repetitive Surge Forward Current(TJ =
45℃,t=10ms,50Hz,Sine)
Power Dissipation
Junction Temperature Range
Storage Temperature Range
Module-to-Sink(Recommended M3)
T
C
= 25° unless otherwise noted
C
Symbol
V
R
V
RRM
I
F(AV)
I
F(RMS)
I
FSM
Value
600
600
60
90
600
Unit
V
V
A
A
A
P
D
T
J
T
STG
Torque
Weight
250
-40 to +150
-40 to +150
1.1
6.0
W
℃
℃
Nm
g
Thermal Characteristics
Parameter
Thermal Resistance, Junction-to-Case
R
θJC
Symbol
Value
0.5
Unit
°
C/W
Version 1.0 , 2016
1
www.lonten.cc
LDB60U60W4
Package Marking and Ordering Information
Device
LDB60U60W4
Device Package
TO-247
Marking
LDB60U60W4
Electrical Characteristics
Symbol
I
RM
T
J
= 25° unless otherwise noted
C
Parameter
Reverse Leakage Current
Test Conditions
V
R
=600V
V
R
=600V, T
J
=125℃
I
F
=60A
Min.
--
--
--
--
--
Typ.
--
--
1.9
1.7
25
45
2.5
125
6.5
Max.
10
1000
2.4
--
--
--
--
--
--
Unit
uA
uA
V
V
ns
ns
A
ns
A
V
F
Forward Voltage
I
F
=60A, T
J
=125℃
I
F
=1A, V
R
=30V,
t
rr
t
rr
I
RRM
t
rr
I
RRM
Reverse Recovery Time
di
F
/dt=-200A/us
Reverse Recovery Time
Max. Reverse Recovery Current
Reverse Recovery Time
Max. Reverse Recovery Current
V
R
=300V, I
F
=60A
di
F
/dt=-200A/us, T
J
=25℃
V
R
=300V, I
F
=60A
di
F
/dt=-200A/us, T
J
=125℃
--
--
--
--
Electrical Characteristics Diagrams
Figure 1. Forward Voltage Drop vs Forward Current
Figure 2. Reverse Recovery Time vs diF/dt
Version 1.0 , 2016
2
www.lonten.cc
LDB60U60W4
Figure 3. Reverse Recovery Current vs diF/dt
Figure 4. Reverse Recovery Charge vs diF/dt
Figure 5. Dynamic Parameters vs Junction Temperature
Figure 6. Transient Thermal Impedance
Figure 7. Diode Reverse Recovery Test Circuit and Waveform
Version 1.0 , 2016
3
www.lonten.cc
LDB60U60W4
Figure 8. Package Outline
Dimensions in Millimeters
Marking Information
Lonten Logo
“Eww” Date Code
“xx” Lot ID
“D” single
“B” package type TO-247
“60”(the first) 10% of V
RRM
“U” Ultra fast recovery
“60” (the second) Nominal Current
“W4” wafer foundry code
Version 1.0 , 2016
4
www.lonten.cc
LDB60U60W4
Disclaimer
The content specified herein is for the purpose of introducing LONTEN's products (hereinafter "Products").
The information given in this document shall in no event be regarded as a guarantee of conditions or
characteristics. Examples of application circuits, circuit constants and any other information contained herein
illustrate the standard usage and operations of the Products. The peripheral conditions must be taken into
account when designing circuits for mass production.
LONTEN does not assume any liability for infringement of patents, copyrights, or other intellectual property
rights of third parties by or arising from the use of the Products or technical information described in this
document.
The Products are not designed or manufactured to be used with any equipment, device or system which
requires an extremely high level of reliability the failure or malfunction of which may result in a direct threat to
human life or create a risk of human injury (such as a medical instrument, transportation equipment,
aerospace machinery, nuclear-reactor controller, fuel-controller or other safety device). LONTEN shall bear no
responsibility in any way for use of any of the Products for the above special purposes.
Although LONTEN endeavors to improve the quality and reliability of its products, semiconductor products
have specific characteristics such as the occurrence of failure at a certain rate and malfunctions under certain
use conditions. Please be sure to implement safety measures to guard them against the possibility of physical
injury, and injury or damage caused by fire in the event of the failure of a LONTEN product.
The content specified herein is subject to change for improvement without notice. When using a LONTEN
product, be sure to obtain the latest specifications.
Version 1.0 , 2016
5
www.lonten.cc