LDC60U08W4\LDD60U08W4
600V 8A Fast Recovery Diode
Description
FRED
from
Lonten
utilizes
advanced
processing
techniques to achieve ultra-fast recovery times and
higher forward current. Its soft recovery characteristics
and high reliability suit for wide industrial applications
.
Product Summary
600V
8A
FRED
TO-220 Pin Configuration
Features
Low power loss, high efficiency
High reliability
RoHS product
TO-220HF-2L
TO-220C-2L
Applications
A
K
A
K
Active power factor correction
Switch power supply
PFC
Absolute Maximum Ratings
Parameter
Maximum D.C. Reverse Voltage
Maximum Repetitive Reverse Voltage
Average Forward Current( Tc = 110℃)
RMS Forward Current( Tc = 110℃)
Non-Repetitive Surge Forward Current(TJ =
45℃,t=10ms,50Hz,Sine)
Power Dissipation
Junction Temperature Range
Storage Temperature Range
Module-to-Sink(Recommended M3)
T
C
= 25° unless otherwise noted
C
Symbol
V
R
V
RRM
I
F(AV)
I
F(RMS)
I
FSM
Value
600
600
8
21
80
Unit
V
V
A
A
A
P
D
T
J
T
STG
Torque
Weight
83
-50 to +150
-50 to +150
1.1
2.1
W
℃
℃
Nm
g
Thermal Characteristics TO-220HF2L
Parameter
Thermal Resistance, Junction-to-Case
R
θJC
Symbol
Value
3.5
Unit
°
C/W
Thermal Characteristics TO-220C2L
Parameter
Thermal Resistance, Junction-to-Case
R
θJC
Symbol
Value
2.2
Unit
°
C/W
Version 1.0 , 2016
1
www.lonten.cc
LDC60U08W4\LDD60U08W4
Package Marking and Ordering Information
Device
LDD60U08W4
LDC60U08W4
Device Package
TO-220HF-2L
TO-220C-2L
Marking
LDD60U08W4
LDC60U08W4
Electrical Characteristics
Symbol
I
RM
Parameter
T
J
= 25° unless otherwise noted
C
Test Conditions
V
R
=600V
V
R
=600V, T
J
=125℃
I
F
=8A
I
F
=8A, T
J
=125℃
I
F
=1A, V
R
=30V,
di
F
/d
t
=-200A/us
Min.
--
--
--
--
--
Typ.
--
--
1.8
1.5
19
Max.
50
200
2.4
2.1
30
Unit
uA
uA
V
V
ns
Reverse Leakage Current
V
F
Forward Voltage
t
rr
Reverse Recovery Time
Electrical Characteristics Diagrams
Figure 1. I
F
vs V
F
Figure 2. I
R
vs V
R
I
F
(A)
V
F
(V)
I
R
(A)
V
R
(V)
Figure3. Diode Reverse Recovery Test Circuit and Waveform
Version 1.0 , 2016
2
www.lonten.cc
LDC60U08W4\LDD60U08W4
Figure4. Package Outline Dimensions in Millimeters
Mechanical Dimensions for TO-220HF-2L
Symbol
A
B1
b
c
D
D2
E
e
F
L
L2
ΦP
Q
Q1
MIN
4.0
0.87
0.72
0.5
15.0
7.8
9.62
MAX
5.0
1.27
0.92
0.7
16.5
9.4
10.62
2.54(TYP.)
2.3
13.0
3.1
3.0
3.15
2.2
3.3
14.0
3.5
3.4
3.55
2.5
Mechanical Dimensions for TO-220C-2L
Symbol
A
B
b
c
D
D2
E
e
F
L
L1
L2
Q
Q1
P
MIN
4.30
1.22
0.70
0.40
15.20
9.00
9.70
2.39
1.25
12.60
0.20
2.80
2.60
2.20
3.5
MAX
4.70
1.40
0.95
0.65
16.20
9.40
10.10
2.69
1.40
13.60
0.50
3.20
3.00
2.60
3.80
Version 1.0 , 2016
3
www.lonten.cc
LDC60U08W4\LDD60U08W4
Marking Information
Lonten Logo
“Eww” Date Code
“xx” Lot ID
“D” single
“x” package type. “C”TO-220C, “D”TO-220HF
“60” 10% of V
RRM
“U” Ultra fast recovery
“08” Nominal Current
“W4” wafer foundry code
Version 1.0 , 2016
4
www.lonten.cc
LDC60U08W4\LDD60U08W4
Disclaimer
The content specified herein is for the purpose of introducing LONTEN's products (hereinafter "Products").
The information given in this document shall in no event be regarded as a guarantee of conditions or
characteristics. Examples of application circuits, circuit constants and any other information contained herein
illustrate the standard usage and operations of the Products. The peripheral conditions must be taken into
account when designing circuits for mass production.
LONTEN does not assume any liability for infringement of patents, copyrights, or other intellectual property
rights of third parties by or arising from the use of the Products or technical information described in this
document.
The Products are not designed or manufactured to be used with any equipment, device or system which
requires an extremely high level of reliability the failure or malfunction of which may result in a direct threat to
human life or create a risk of human injury (such as a medical instrument, transportation equipment,
aerospace machinery, nuclear-reactor controller, fuel-controller or other safety device). LONTEN shall bear no
responsibility in any way for use of any of the Products for the above special purposes.
Although LONTEN endeavors to improve the quality and reliability of its products, semiconductor products
have specific characteristics such as the occurrence of failure at a certain rate and malfunctions under certain
use conditions. Please be sure to implement safety measures to guard them against the possibility of physical
injury, and injury or damage caused by fire in the event of the failure of a LONTEN product.
The content specified herein is subject to change for improvement without notice. When using a LONTEN
product, be sure to obtain the latest specifications.
Version 1.0 , 2016
5
www.lonten.cc