Features
特性
Relay Picture
HCP2
POWER RELAY
Low profile, height 15.8mm
Dimensions: 29.0×12.6×15.8(mm)
Switching capacity 8A
Contact: 2 Form A, 2 Form C
Sensitivity 400mW
Insulation: 5KV
Creepage:10mm
Safety Approval
c
US
NO.E164730
NO.CQC09002030014
NO.
40043990
NO.50062453
ORDERING INFORMATION
HCP2
Enclosure
Model
S - Plastic Sealed Type
S
DC12V
Coil Voltage
DC5V, DC6V, DC9V,
DC12V, DC24V, DC48V
C
Contact Form
A - 2 Form A
C - 2 Form C
SPECIFICATION
CONTACT DATA
Contact Form
Contact Material
Contact Rating
Contact Resistance
Max. Switching Voltage
Load
Max. Switching Current
Max. Switching Power
Min. Switching Load
Electrical
Life
Mechanical
2 Form A, 2 Form C
Ag Alloy
Resistive:8A 250VAC/30VDC
Inductive:4A
250VAC Cosφ=0.4
Max. 100mΩ (6VDC 1A)
440VAC/120VDC
8A
2,000VA, 240W
5VDC, 100mA
100,000 operations
50,000 operations
(Inductive:
Cosφ=0.4, L/R=7ms)
20,000,000 operations
GENERAL DATA
Insulation Resistance
Dielectric
Strength
Min. 1000MΩ 500VDC
1,000VAC, 1min
5,000VAC, 1min
Max. 10ms
Max. 5ms
-40℃ to +85℃
35½95%RH, +40℃
1,000m/s
100m/s
2
2
Between open contacts
Between coil and contacts
Operate Time
Release Time
Operating Temperature
Humidity
Endurance
Shock
Resistance Misoperation
Endurance
10½55Hz, 1.5mm double amplitude
Vibration
Resistance Misoperation 10½55Hz, 1.5mm double amplitude
Weight
Approximately 13.00g
Note:Data shown are of initial value
COIL DATA
Nominal Coil Power
400mW
SAFETY APPROVAL
File Number
UL E164730
TUV 50062453-0002
CQC09002030014
(GB/T 21711.1-2008)
Power
Contact
Form Consumption
A/C
A/C
A/C
A
0.4W
0.4W
0.4W
0.4W
Coil
Voltage
5-110VDC
5,6,9,12,24,48,60,110VDC
5,6,9,12,24,48,60,110VDC
5,6,9,12,18,24,36,48VDC
calss:F
8A 250VAC
InsulationTemperature: 85℃
Ambient
Contact
Rating
Remarks
8A 250VAC
8A 250VAC
8A 250VAC
Ambient Temperature: 85℃
Ambient Temperature: 85℃
Ambient Temperature: 85℃
VDE 40043990
Specifications subject to change without notice
ISO9001、ISO/TS16949、ISO14001 Approved
HCP2-108
HCP2
POWER RELAY
COIL DATA
Model
HCP2-S-DC5V
HCP2-S-DC6V
HCP2-S-DC9V
HCP2-S-DC12V
HCP2-S-DC24V
HCP2-S-DC48V
Nominal Voltage Coil Resistance
Ω+/-10%
VDC
5
6
9
12
24
48
62.5
90.0
202.5
360
1440
5760
Ambient Temperature: 23℃
Operate Voltage Release Voltage
≥VDC
≤VDC
3.5
4.2
6.3
8.4
16.8
33.6
0.5
0.6
0.9
1.2
2.4
4.8
400
Coil Power
mW
OUTLINE, WIRING DIAGRAM, MOUNTING HOLE LAYOUT (UNIT: mm)
Mounting Hole Layout
2 Form C
(Bottom View)
5.08±0.1
Outline
29.0±0.3
12.6±0.3
+0.1
5.08±0.1
7.6±0.1
15.8±0.3
8-O1.3
0
20.32±0.1
1.1±0.3
Wiring Diagram
(Bottom View)
2-0.5±0.1
6-0.5±0.1
5.08±0.3
20.32±0.3
5.08±0.3
3.8±0.3
2-0.5±0.1
6-0.8±0.1
7.6±0.3
Mounting Hole Layout
2 Form A
(Bottom View)
Outline
29.0±0.3
12.6±0.3
+0.1
5.08±0.1
7.6±0.1
6-O1.3
0
20.32±0.1
1.1±0.3
15.8±0.3
Wiring Diagram
(Bottom View)
2-0.5±0.1
4-0.5±0.1
5.08±0.3
20.32±0.3
5.08±0.3
3.8±0.3
2-0.5±0.1
4-0.8±0.1
7.6±0.3
ISO9001、ISO/TS16949、ISO14001 Approved
HCP2-109
HCP2
POWER RELAY
REFERENCE DATA
Maximum Switching Power
Contact Current (A)
1000
Life Curve
50
Operations (×10,000)
10
AC
5
100
1
DC
10
0.5
0.1
1
10
20
30
40 50
100
200
300
400
500
0
0.4
0.8
1.2
1.6
2.0
2.4
2.6
2.8
3.2
3.6
4.0
Contact
Voltage (V)
Switching Power
(KVA)
Max. Ambient Temp. Vs. Coil Voltage
Applied Coil Voltage (% of nominal voltage)
300
260
220
180
140
100
60
0A
8A
B
A
0
20
40
60
80
100
Max. Ambient Temp. (℃)
A: Coil temperature = Ambient temperature.
B: 110% of nominal coil voltage at rated contact load.
ISO9001、ISO/TS16949、ISO14001 Approved
HCP2-110