1/10
Magnetic Switch
Reference Only
MRMS201A
Sensor Products Division
Data Sheet
1. Scope
This data sheet is applied to the magnetic switch MRMS201A.
2. Part number
2-1 Part Description
Magnetic Switch
2-2 Murata Part Number MRMS201A
3. Dimensions and Schematics
3-1 Dimensions
Direction of applied
magnetic field
(N or S)
Coplanarity : less than 0.1mm(includiong under reflow condition)
Dimension
Ⅰ.
Ⅰ.
Ⅰ.
(E.g.)
「」9
1
↓ ↓ ↓
ⅠⅠⅠ
Control code...One alphabetic character
Manufactured year...The last digit of the year
Manufactured month..
Jan to Sep : 1 to 9
Oct to Dec : X, Y, Z
Marking Example
Murata Manufacturing Co., LTD.
2/10
Reference mount pad
3-2 Block wiring diagram
Vcc
R1
R2
Latch
and
Switch
CMOS
Driver
Op-Amp
Out
R3
R4
Gnd
The intermittent switch circuit inside
3-3
Magnetic electric conversion characteristic
V
OUT
V
OH
V
OL
N pole
Hon
Hoff
Hoff
Hon
S pole
Murata Manufacturing Co., LTD.
3/10
3-4
Timing Diagram
[Typ:5mA(V
CC
=3.0V)]
[Typ:2.5μA(V
CC
=3.0V)]
Magnetic Field Applied
Magnetic Field Released
3-5
Electric Characteristics/ Absolute Maximum Rating (Ta=+25
o
C Vcc=3.0V)
Parameter
Supply voltage
Absolute max. supply voltage
Current consumption
Symbol
V
cc
-
I
AVE
H
on
Conditions
-
-
Average
V
cc
=3.0V
+25℃
-40~+85
o
C
+25℃
H
off
-40~+85
o
C
Iout=+2mA
Iout=-2mA
-
Min.
1.6
-
-
-
-
0.5
0.2
2.7
-
-40
-
-
-
-
0.3
+85
V
V
o
Typ.
3.0
-
5
-
-
Max.
3.5
6.0
12
2.5
3.0
Unit
V
V
uA
1
2
3
4 Operating magnetic field
mT
5
6
7
Hi level output
Lo level output
Operating temp. range
V
0H
V
OL
-
C
Storage temp. range
o
-
-
-
8
-40
+125
C
NOTE1) Each specification is defined by testing above items individually.
NOTE2) When shifting the sensor output from H to L, please make sure the magnetic field
applied to the sensor becomes higher than the above operating magnetic field (Hon)
through your designing.
NOTE3) When shifting the sensor output from L to H, please make sure the magnetic field
applied to the sensor becomes lower than the above operating magnetic field (Hoff)
through your designing.
NOTE4) Sensitivity selection of this product is performed at Vcc=3.0V. Operating magnetic field
can possibly change when applying the supply voltage other than 3.0V. Please consult
with us for technical assistance when you consider the supply voltage other than 3.0V, as
a special attention needs to be given in the design.
3-6 Packing information
Form of packing
Reel dimension
Tape & reel
φ180
Pcs per reel
3000pcs
Murata Manufacturing Co., LTD.
4/10
3-7 Taping specifications
3-7-1 Taping dimensions
Unit:mm
Parameter
Length
Width
Pocket
Depth
Pitch
Diameter
Feed hole
Pitch
Position
Overall thickness
Symbol
A
B
K
0
F
J
H
E
K
Size/
Angle
3.35±0.1
3.2±0.1
1.4±0.1
4.0±0.1
+0.1
φ1.5
-0.05
4.0±0.1
1.75±0.1
1.55±0.1
Parameter
Dist. Between
center lines
Cover tape
Carrier tape
L direction
W direction
Width
Width
Thickness
Depth
Tilt
Symbol
G
D
W
C
T
K
1
θ
Size/
Angle
2.0±0.05
3.5±0.05
+0.3
5.5
-0
8.0±0.1
0.2±0.05
1.5±0.1
30°MAX
Device
3-7-2
Reel dimensions...EIAJ PRV08B compliant
θ
1
θ
2
Unit: mm
Item
Diameter
C
B
A
Symbol
A
W
B
Dim/Angle
φ178±2
9±0.5
φ60±1
Dis. between flanges
Diameter
Hub slit position
Spindle hole diam.
Key slit position
Marking
θ1
90°
C
φ13±0.5
θ2
120°
Labeled on one side of
flange
W
Murata Manufacturing Co., LTD.
5/10
3-7-3
Start/End of taping
Reel label A (example)
Trailer 160mm or more
Product containing part
Leader
Product containing part
Empty part:
100mm or more
Leader:
Cover tape
400mm or more
Reel label B (example)
3-7-4 Other notes
Continuously missing device shall not exceed 2 pcs.
Peeling strength of the cover tape: 0.1 to 0.7N.
Murata Manufacturing Co., LTD.