MCC
omponents
21201 Itasca Street Chatsworth
!"#
$
% !"#
1N6095
thru
1N6096
25
Amp
Schottky
30 to 40
Volts
DO-4
B
Features
•
•
•
•
Metal of siliconrectifier, majonty carrier conducton
Guard ring for transient protection
Low power loss high efficiency
High surge capacity, High current capability
Maxi mum Rati ngs
•
•
Operating Junction Temperature: -65°C to +150°C
Storage Temperature: -65°C to +150°C
Maximum
Recurrent
Peak Reverse
Voltage
30V
40V
Maximum DC
Blocking
Voltage
30V
40V
MCC
Part Number
1N6095
1N6096
Maximum
RMS Voltage
21V
28V
N
M
C
J
P
H
F
G
D
Electrical Characteristics @ 25°C Unless Otherwise Specified
Average Forward
Current
Peak Forward Surge
Current
Maximum
Instantaneous
Forward Voltage
Maximum DC
Reverse Current At
Rated DC Blocking
Voltage
I
F(AV)
I
FSM
25
A
400A
T
A
=
70°C
8.3ms, half sine
I
FM
=
78.5
A;
T
C
=
70°C
DIM
A
B
C
D
E
F
G
H
J
M
N
P
E
A
DIMENSIONS
INCH
ES
MIN
10-32 UNF3A
.424
-----
.600
.422
.075
-----
.163
-----
-----
.020
.060
MM
MIN
MAX
Standard
Polarity
10.77
11.10
-----
12.82
15.24
20.32
10.72
11.50
1.91
4.44
-----
10.29
4.15
4.80
-----
7.87
-----
8.89
0.51
1.65
1.53
2.54
V
F
.86V
I
R
20mA
250mA
T
A
= 25°C
T
A
= 125°C
MAX
Threads
.437
.505
.800
.453
.175
.405
.189
.310
.350
.065
.100
NOTE
∅
∅
*Pulse Test: Pulse Width 300µsec, Duty Cycle 2%
www.mccsemi.com
1N6095 thru 1N6096
Figure 1
Typical Forward Characteristics
200
100
60
25
40
20
70°C
Amps 10
6
4
2
1
.6
.4
.2
.1
0.2
0.3
0.4
0.6
Volts
Instantaneous Forward Current - Amperes
versus
Instantaneous Forward Voltage - Volts
0.8
1.0
500
400
300
Figure
3
Peak Forward Surge Current
600
100
500
400
300
Amps
200
100
0
1
2
4
6
8 10 20
Cycles
Peak Forward Surge Current - Amperes
versus
Number Of Cycles At 60Hz - Cycles
40
60 80 100
2
1
.6
.4
.2
.1
20
40
60
40
20
mAmps
10
6
4
200
0
Amps
10
15
20
30
MCC
Figure 2
Forward Derating Curve
5
Single Phase, Half Wave
60Hz Resistive or Inductive Load
0
30
50
70
°C
100
125
150
Average Forward Rectified Current - Amperes
versus
Ambient Temperature -
°C
Figure 4
Typical Reverse Characteristics
T
A
=125°C
T
A
= 25°C
50
60
Volts
70
80
90
Instantaneous Reverse Leakage Current - MicroAmperes
versus
Percent Of Rated Peak Reverse Voltage - Volts
www.mccsemi.com