https://www.phoenixcontact.com/pi/products/1506561
Sensor/actuator cable - SAC-4P-M12FR-2L/.../... - 1506561
Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's
documentation. Our General Terms of Use for Downloads are valid
(http://phoenixcontact.com/download)
Sensor/actuator cable, 4-position, Variable cable type, free cable end, on Socket angled M12, A-coded, with 2
LEDs, cable length: Free input (0.2 ... 40.0 m)
Your advantages
Easy and safe: 100% electrically tested plug-in components
Flexible solutions - configurable materials with variable cable types and cable lengths
Convenient: increased machine availability thanks to quick and easy diagnostics
Key Commercial Data
Packing unit
Minimum order quantity
1 pc
25 pc
Configuration
Cable type
Length [m]
PVC gray [500]
1
Technical data
Dimensions
Length of cable
Stripping length of the free conductor end
Free input (0.2 ... 40.0 m)
50 mm
Ambient conditions
Ambient temperature (operation)
Degree of protection
-25 °C ... 90 °C (Plug / socket)
IP65
IP67
IP68
General
Rated current at 40°C
Rated voltage
4A
24 V
24 V DC
11/05/2018 Page 1 / 18
https://www.phoenixcontact.com/pi/products/1506561
Sensor/actuator cable - SAC-4P-M12FR-2L/.../... - 1506561
Technical data
General
Number of positions
Insulation resistance
Coding
Status display
Protective circuit/component
Overvoltage category
Degree of pollution
Insertion/withdrawal cycles
4
≥ 100 MΩ
A - standard
2 LEDs
Unwired
II
3
≥ 100
Material
Flammability rating according to UL 94
Contact material
Contact surface material
Contact carrier material
Material of grip body
Material, knurls
Sealing material
HB
CuSn
Ni/Au
TPU GF
TPU, hardly inflammable, self-extinguishing
Zinc die-cast, nickel-plated
NBR
Line characteristics
Note
This item is a sensor/actuator cable with a freely selectable cable type.
The technical data for all possible cable types is listed in the table below.
Standards and Regulations
Flammability rating according to UL 94
HB
PUR/PVC gray [100]
Cable type
Cable type (abbreviation)
Cable abbreviation
Conductor cross section
AWG signal line
Conductor structure signal line
Core diameter including insulation
Thickness, insulation
PUR/PVC gray
100
LiYY-11Y
0.34 mm²
22
42x 0.10 mm
1.5 mm ±0.05 mm
≥ 0.3 mm (Core insulation)
≥ 0.38 mm (Outer cable sheath)
approx. 0.35 mm (Inner sheath)
Wire colors
Overall twist
External sheath, color
External cable diameter D
Smallest bending radius, fixed installation
Smallest bending radius, movable installation
Number of bending cycles
brown, white, blue, black
4 wires, twisted
gray RAL 7001
5.2 mm ±0.2 mm
52 mm
52 mm
2000000
11/05/2018 Page 2 / 18
https://www.phoenixcontact.com/pi/products/1506561
Sensor/actuator cable - SAC-4P-M12FR-2L/.../... - 1506561
Technical data
PUR/PVC gray [100]
Bending radius
Traversing path
Traversing rate
Cable weight
Outer sheath, material
Material, inner sheath
Material conductor insulation
Conductor material
Insulation resistance
Conductor resistance
Nominal voltage, cable
Test voltage, cable
Flame resistance
Ambient temperature (operation)
52 mm
5m
3 m/s
39 kg/km
PUR
PVC
PVC
Bare Cu litz wires
≥ 100 MΩ*km (at 20 °C)
max. 58 Ω/km (at 20 °C)
≤ 300 V
≥ 3000 V
in accordance with DIN UL-Style 20549
-25 °C ... 80 °C (cable, fixed installation)
-5 °C ... 80 °C (cable, flexible installation)
PUR/PVC yellow [140]
Cable type
Cable type (abbreviation)
Cable abbreviation
UL AWM style
Conductor cross section
AWG signal line
Conductor structure signal line
Core diameter including insulation
Thickness, insulation
PUR/PVC yellow
140
LiYY-11Y
20549
0.34 mm²
22
42x 0.10 mm
1.5 mm ±0.05 mm
approx. 0.3 mm (Core insulation)
≥ 0.38 mm (Outer cable sheath)
approx. 0.35 mm (Inner sheath)
Wire colors
Overall twist
External sheath, color
External cable diameter D
Smallest bending radius, fixed installation
Smallest bending radius, movable installation
Number of bending cycles
Bending radius
Traversing path
Traversing rate
Cable weight
Outer sheath, material
Material, inner sheath
brown, white, blue, black
4 wires, twisted
yellow
5.2 mm ±0.2 mm
52 mm
52 mm
2000000
52 mm
5m
3 m/s
39 kg/km
PUR
PVC
11/05/2018 Page 3 / 18
https://www.phoenixcontact.com/pi/products/1506561
Sensor/actuator cable - SAC-4P-M12FR-2L/.../... - 1506561
Technical data
PUR/PVC yellow [140]
Material conductor insulation
Conductor material
Insulation resistance
Conductor resistance
Nominal voltage, cable
Test voltage, cable
Flame resistance
Ambient temperature (operation)
PVC
Bare Cu litz wires
≥ 1 GΩ*km (at 20 °C)
max. 58 Ω/km (at 20 °C)
≤ 300 V
≥ 3000 V
in accordance with DIN UL-Style 20549
-25 °C ... 80 °C (cable, fixed installation)
-5 °C ... 80 °C (cable, flexible installation)
PUR irradiated halogen-free orange [150]
Cable type
Cable type (abbreviation)
Cable abbreviation
Conductor cross section
AWG signal line
Conductor structure signal line
Core diameter including insulation
Wire colors
Overall twist
Length of twist, overall twist
External sheath, color
External cable diameter D
Smallest bending radius, fixed installation
Smallest bending radius, movable installation
Number of bending cycles
Bending radius
Traversing path
Traversing rate
Torsion force
Outer sheath, material
Material conductor insulation
Conductor material
Conductor resistance
Nominal voltage, cable
Test voltage, cable
Special properties
Halogen-free
Other resistance
PUR irradiated halogen-free orange
150
D12YSL11X-OB
4x 0.34 mm²
22
19x 0.15 mm
1.05 mm ±0.05 mm (Signal line)
brown, white, blue, black
4 wires, twisted
27 mm
orange RAL 2003
5.2 mm ±0.2 mm
min. 15 mm
min. 30 mm
5000000
52 mm
10 m
3 m/s
± 360 °/m
PUR
PE
Bare Cu litz wires
max. 57 Ω/km
320 V (AC)
2500 V (50 Hz, 5 minutes)
Silicone-free
Irradiated
The cable is halogen-free
hydrolysis and microbe resistant
Resistant to welding splashes
11/05/2018 Page 4 / 18
https://www.phoenixcontact.com/pi/products/1506561
Sensor/actuator cable - SAC-4P-M12FR-2L/.../... - 1506561
Technical data
PUR irradiated halogen-free orange [150]
Ambient temperature (operation)
-50 °C ... 105 °C (cable, fixed installation)
-40 °C ... 105 °C (cable, flexible installation)
PUR irradiated halogen-free yellow [160]
Cable type
Cable type (abbreviation)
Conductor cross section
AWG signal line
Conductor structure signal line
Core diameter including insulation
Wire colors
Overall twist
Length of twist, overall twist
External sheath, color
External cable diameter D
Smallest bending radius, fixed installation
Smallest bending radius, movable installation
Number of bending cycles
Bending radius
Traversing path
Traversing rate
Torsion force
Outer sheath, material
Material conductor insulation
Conductor material
Conductor resistance
Nominal voltage, cable
Test voltage, cable
Special properties
Flame resistance
Halogen-free
Other resistance
Ambient temperature (operation)
PUR irradiated halogen-free yellow
160
4x 0.34 mm² (Signal line)
22
19x 0.15 mm
1.05 mm ±0.05 mm (Signal line)
brown, white, blue, black
4 wires, twisted
27 mm
yellow
5.2 mm ±0.2 mm
min. 15 mm
min. 30 mm
5000000
52 mm
10 m
3 m/s
360 °/m
PUR
PE
Bare Cu litz wires
≤ 57 Ω/km
320 V AC
2500 V AC (50 Hz, 5 minutes)
Silicone-free
Irradiated
DIN VDE 0472 part 804, test type B
The cable is halogen-free
hydrolysis and microbe resistant
-50 °C ... 105 °C (cable, fixed installation)
-40 °C ... 105 °C (cable, flexible installation)
PUR halogen-free orange [180]
Cable type
Cable type (abbreviation)
Cable abbreviation
UL AWM style
Conductor cross section
PUR halogen-free orange
180
Li9Y-11Y
20549
4x 0.34 mm² (Signal line)