SRBH-06H1A1
Non-Isolated DC-DC Converter
The SRBH-06H1A1 is part of the low cost non-isolated dc/dc
power converter series providing up to 6A output current.
The output is closely regulated and the efficiency of 3.3Vdc
output is typically 89% at full load.
Typical features include remote on/off, input under voltage
lockout, over current protection and short circuit protection.
Key Features & Benefits
8-36 VDC Input / 3.3-5 VDC @ 6 A Output
Non-isolated output
High Efficiency
High Power Density
Excellent Thermal Performance
OCP/SCP
Remote On/Off
Input Under Voltage Lockout
Low Cost
Class 2, Category 2, Non-Isolated DC/DC Converter (refer to
IPC-9592B)
Applications
Distributed Power Architectures
Data Networking Equipment
Telecommunications Applications
belpowersolutions.com
2
SRBH-06H1A1
MAX.
OUTPUT
CURRENT
6A
MAX.
OUTPUT
POWER
30 W
1. MODEL SELECTION
MODEL
NUMBER
SRBH-06H1A1
OUTPUT
VOLTAGE
3.3V -5V
INPUT
VOLTAGE
8 V- 36 V
TYPICAL EFFICIENCY
89%(Vo=3.3, Io=6A)
NOTE:
Add “G” suffix at the end of the model number to indicate Tray Packaging
or
“R” indicating Tape and Reel packaging.
PART NUMBER EXPLANATION
S
Mounting Type
SMD
R
RoHS
Status
RoHS
BH
Series Name
Arrow Head
-
06
Output
Current
6A
H
Input Range
8V – 36V
1A
Output Voltage
1
Active Logic
Active High
x
Package Type
G – Tray Package
R – Tape & Reel
3.3V -5.0V
2. ABSOLUTE MAXIMUM RATINGS
PARAMETER
Continuous Non-operating Input Voltage
Remote On/Off
Ambient Temperature
Storage Temperature
Altitude
DESCRIPTION
MIN
-0.3
-0.3
-40
-40
-
TYP
-
-
-
-
-
MAX
38
12
85
125
2000
UNITS
V
V
C
C
m
NOTE:
Ratings used beyond the maximum ratings may cause a reliability degradation of the converter or may permanently damage the
device.
3. INPUT SPECIFICATIONS
All specifications are typical at 25°C unless otherwise stated.
PARAMETER
Operating Input Voltage
Input Current (full load)
Input Current (no load)
Remote Off Input Current
Input Reflected Ripple Current (rms)
Input Reflected Ripple Current (pk-pk)
I2t Inrush Current Transient
Turn on Voltage Threshold
Turn off Voltage Threshold
Input under voltage lockout (UVLO).
1uH, 2*100 uF/50 V electrolytic capacitors, 3*4.7
uF/50V ceramic capacitor at the input.
Vin=12V,Vo=3.3V,Io=6A
DESCRIPTION
MIN
8
-
-
-
-
-
-
-
-
TYP
-
1.9
30
TBD
50
70
TBD
7.5
4
MAX
36
-
-
-
-
-
-
-
-
UNITS
V
A
mA
mA
mA
mA
A2s
V
V
CAUTION:
All specifications are typical at nominal input, full load at 25°C unless noted.
tech.support@psbel.com
belpowersolutions.com
SRBH-06H1A1
4. OUTPUT SPECIFICATIONS
All specifications are typical at nominal input, full load at 25°C unless otherwise stated.
PARAMETER
Output Voltage Set Point
Load Regulation
Line Regulation
Regulation Over Temperature
Ripple and Noise (pk-pk)
Vout=3.3V
Ripple and Noise (rms)
Output Current Range
Output DC Current Limit
Turn on Time(from Vin)
Turn on Time(from Enable)
Output capacitance
Transient Response
△V
50%~100% of Max Load
Settling Time
△V
100%~50% of Max Load
Settling Time
di/dt = 0.5 A/us; Vin = 12 V; Vout=3.3V; with a
220 uF Oscan capacitor at the output
-
-
-
-
80
200
80
200
150
300
150
300
Hiccup mode
-
0
8
-
-
220
25
-
10
6
1
-
50
6
12
10
-
1200
-40 °C to +85 °C
3
DESCRIPTION
Vin=12 V, Io=50% full load
MIN
3.234
-
-
-
-
TYP
3.300
±5
±5
30
60
MAX
3.366
±10
±10
50
100
UNITS
V
mV
mV
mV
mV
mV
A
A
ms
ms
uF
mV
us
mV
us
5. GENERAL SPECIFICATION
PARAMETER
Efficiency
Switching Frequency
Output Trim Range
Over Voltage Protection
Weight
MTBF
Dimensions
Inches (L × W × H)
Millimeters (L × W × H)
V
OVTH
DESCRIPTION
Vin=12V Vo=3.3V full load
MIN
87
-
3.3
116
-
-
TYP
89
300
-
121
TBD
TBD
MAX
-
-
5
127
-
-
UNITS
%
KHz
V
%
g
hours
Inches
mm
0.885 x 0.512 x 0.320
22.48 x 13.00 x 8.13
6. CONTROL/SUPERVISORY SPECIFICATIONS
PARAMETER
Enable
Signal Low (Unit Off)
Signal High(Unit On)
Sourcing current
ENABLE pin open, unit off
-0.3
2.8
-
-
-
-
1
12
10
V
V
uA
DESCRIPTION
MIN
TYP
MAX
UNITS
Asia-Pacific
+86 755 298 85888
Europe, Middle East
+353 61 225 977
North America
+1 408 785 5200
Rev. AA
© 2016 Bel Power Solutions & Protection
4
SRBH-06H1A1
7. EFFICIENCY DATA
Efficiency vs. Output Current at Tmin
100.0%
90.0%
80.0%
EFFICIENCY (%)
70.0%
60.0%
50.0%
40.0%
30.0%
20.0%
10.0%
0.0%
8V
36V
12
24V
0A 0.3A
0.6A1.2A1.8A2.4A 3A 3.6A
4.2A
4.8A5.4A 6A
OUTPUT CURRENT (Amp)
8. THERMAL DERATING CURVE
Vin=12V, Vo=3.3V
tech.support@psbel.com
belpowersolutions.com
SRBH-06H1A1
9. RIPPLE AND NOISE WAVEFORM
5
Ripple and noise at no load, Vin=12V
Ripple and noise at full load, Vin=12V
Ripple and noise at no load, Vin=24V
Ripple and noise at full load, Vin=24V
Ripple and noise at no load, Vin=36V
Ripple and noise at full load, Vin=36V
Asia-Pacific
+86 755 298 85888
Europe, Middle East
+353 61 225 977
North America
+1 408 785 5200
Rev. AA
© 2016 Bel Power Solutions & Protection