HIGH VOLTAGE MICROSIZED RAIL SUPPLY
ULTRAVOLT® RS SERIES
Single-output
micro-sized
high voltage
rail supplies
The RS Series offers low-cost, nominal-performance,
bipolar 10 W DC-to-DC high voltage power supplies
for
amplifier and pulser circuits, as well as other applications.
This single-device solution is PCB- or chassis-mountable,
and available in 12 models, ranging from ±50 to ±700
VDC fixed output or over a range of 50 to 100% under
proportional input or analog programmable control.
Optimize bias voltage quickly and easily, using an RS series
component with an output center tap isolated to ±2.5 kV.
State-of-the-art power-conversion technology,
manufacturing processes, and encapsulation techniques
deliver high product reliability.
›
12 bipolar models: 0 to ±50 to ±700 VDC,
or 100 to 1400 VDC unipolar
›
Output voltage: proportional, programmable,
or fixed
›
Output power: 0 to 10 W; no minimum load
›
Accuracy:
≤
±1%
›
Load regulation: < 0.5%
›
Output ripple:
≤
±0.5% Vpk to pk
›
2500 V of isolation from input to output
›
No heat sink or electrical derating required
›
Complimentary to the 1.5/3 W PXS Series
›
> 840,000 hour MTBF per Belcor TR332
TYPICAL APPLICATIONS
PULSE GENERATORS
PZT ACTUATORS
DRIVERS
MEMS DEVICES
LASER AND ELECTRO-
OPTIC MODULATION
ELECTROPHORESIS
BEAM DEVICES
SUCH AS MASS
SPECTROMETERS
AND ELECTRON
MICROSCOPES
AMPLIFIERS
PARAMETER
Input
CONDITIONS
Full Power
Standby/Disable
No Load, Max Eout
Max Load, Max Eout
MODELS
24 V
24 VDC ±5% for 100% of nominal output voltage (See output full scale accuracy
for tolerance)
< 10
< 120 typically 30 to 100, depending on model
< 650 typically 500 to 640, depending on model
UNITS
VDC
mA
mA
mA
Voltage Range
Current
Current
Current
Output (Bipolar)
±50
Nominal Input
50 to 100%
Nominal Input, Max Eout
Iout Entire Output Voltage Range
50
25 to 50
10
100
±75
75
37.5 to 75
10
66
±100
100
50 to 100
10
50
±150
150
75 to 150
10
33
±200
200
100 to 200
10
25
±250
250
125 to 250
10
20
VDC
VDC
VDC
W
mA
Voltage, Fixed
Voltage Range
Proportional
Power
Current
Output (Bipolar)
±300
Nominal Input
50% to 105%, Model Specific
Nominal Input, Max Eout
Iout Entire Output Voltage Range
300
150 to 300
10
16
±350
350
175 to 350
10
14
±400
400
200 to 400
10
12.5
±500
500
250 to 500
10
10
±600
600
300 to 600
10
8.3
±700
700
350 to 700
10
7.1
VDC
VDC
VDC
W
mA
Voltage, Fixed
Voltage Range
Proportional
Power
Current
Output
All Types
Input to Output
Full Load, Max Eout
Full Load, Max Eout, 300 pF
bypass cap, 25% to 50% reduction
½ to Full Load, Max Eout
Nom. Input, Max Eout, Full Power
No Load to Full Load, Max Eout
30 Min. Warmup, Per 8 hr/Per Day
100 MΩ minimum at ±2500
≤
±0.5%
TBD
< ±0.5%
Unregulated: output directly proportional to input, excellent tracking; see TN-XX
≤
±0.5%
< ±2%
VDC
-
VDC
VDC
VDC
%V
pk-pk
Isolation
Ripple
Ripple with -F-M
Option
Dynamic Load
Regulation
Line Regulation
Static Load
Regulation
Stability
Enable/Disable
Adjust Logic
Reference
Environmental
Programming & Controls
TTL 0 or grounded unit is enabled, TTL 1 or any voltage to +32 V or floating unit is disabled
0 to +10 VDC, 50 to 100% of nominal HV output ±1% of full scale (proportional if no connection)
+10 VDC at 1 mA, ±1.0% < ±50 ppm °C
-
-
-
All Types
Full Load, Max Eout, Case Temp.
Non-Operating, Case Temp.
Over the Specific Temperature
All Conditions, Standard Package
Mil-Std-810, Method 516.5, Proc.
IV
Mil-Std-810, Method 514.5,
Fig.514.5C-3
-45 to +75
-55 to +105
< 150
0 to 95%, non-condensing
20
10
°C
°C
PPM/°C
-
G’s
-
Operating
Storage
Temperature
Coefficient
Humidity
Shock
Vibration
PHYSICAL SPECIFICATIONS
Construction
Dimensions (L x Wx H)
Volume
Weight
Tolerance
Epoxy-filled red DAP box certified to ASTM-D-5948
2.25" x 1.125" x 0.75"
57.15 mm x 28.58 mm x 19 mm
31 cc (1.90 in³)
55.2 g (1.95 oz)
All Dimensions
Pin
All dimensions have a tolerance of ±0.010" [0.25 mm] unless otherwise specified.
Standard Thru-hole
Brass, tin over nickel plated, 0.020" (0.51 mm) round