10KW HIGH VOLTAGE POWER SUPPLIES
HITEK POWER OLH10K SERIES
The HiTek Power OLH10K Series is a range of high reliability single output high voltage
power supplies designed to meet the rigorous requirements of ion and electron beam systems,
ion implantation and X-ray equipment.
®
There are three different input voltage variants available to order: the OLH10K (208VAC),
the OLH10KC (380VAC) and the OLH10KE (400VAC).
The systems consist of two units: a rack mounting power converter through which both local
and remote controls can be facilitated, and a separate HV unit employing a modular disc
construction. Numerous features are incorporated to ensure system integrity is maintained
during adverse operating conditions, including HiTek Power’s unique Arc Count and Extinguish
(ACE) system for managing systems where load arcing is endemic.
If none of the models listed below suit your requirements, please contact our Sales Team
to discuss a custom version.
PRODUCT HIGHLIGHTS
10kW of output power
Output voltages from 60kV to 500kV
Robust IGBT converter design
Exceptional reliability
High Stability
Arc Count and Extinguish (ACE)
Full Local & Remote control
Analogue or RS232 remote control
Voltage or current control
RoHS compliant to EU Directive
2002/95/EC
Custom options available
CE Marked
and monitoring
©2018 Advanced Energy Industries, Inc.
HITEK POWER OLH10K SERIES
ELECTRICAL SPECIFICATIONS
Output Power
Output Voltage
Output Current
Input Voltage
OLH10KC
OLH10KE
Polarity
Minimum Voltage
Calibration
Recovery Time
Temperature Coefficient
Drift
Operating Temperature
Storage Temperature
Humidity
Altitude
Installation Category
Pollution Degree
Usage
Protection
Arc Count and Extinguish
(ACE)
Safety
10kW maximum at full rated output voltage and current
Units available with maximum output voltages from 60kV to 500kV
Up to 166mA for 60kV and 10mA for 500kV
OLH10K: 208VAC ±10% (187VAC to 229VAC) 47-63Hz 3 phase plus protective earth
380VAC ±10% (342VAC to 418VAC) 47-63Hz 3 phase plus protective earth
400VAC ±10% (360VAC to 440VAC) 47-63Hz 3 phase plus protective earth
Positive or negative to order
5% of rated output voltage. The unit may be turned down below this but the specifications are not guaranteed
below this level.
Calibration between Voltage Demand, Output Voltage and Voltage Monitor ±0.2% of setting or ±0.05% of
rating, whichever is greater
Less than 200ms to within 0.1% of previous operating level following a short circuit or arc. Maximum overshoot
2% of rated output voltage
Less than 100ppm/°C
Less than 0.01% per hour after 1 hour’s warm up, typically less than 0.02% per 8 hours after 1 hour’s warm up,
at constant load, line and temperature
0°C to +40°C ambient and air intake
-20°C to +85°C
80% maximum relative humidity up to 31 Deg C, reducing linearly to 50% at 40 Deg C. Non-condensing (ref BS
EN61010-1)
Sea level to 2000 metres (6500 feet)
II (BS EN61010-1)
2 (BS EN61010-1)
Indoor use only
The units are fully protected against over voltage, over current, over temperature, load arcing and output short
circuits.
Each time the ACE system detects an arc it blanks the supply off for a brief period to extinguish the arc. The
unit is then allowed to recover. If more arcs occur they are counted to determine the arc rate; if this exceeds a
safe level the power supply is shut down. The parameters are factory set to 25 arcs in any 5 second period.
The OLH10K high voltage power supplies meet the requirements of the Low Voltage Directive, LVD, 2006/95/
EC by complying with BS EN61010-1:2001 when installed as a component part of other equipment. They are
CE marked accordingly.
Equipment Class 1
EN55022 class B for conducted and radiated emissions
EN61000-4-2 ESD - levels ±4kV contact, 8kV air discharge
EN61000-4-4 fast transients on mains input - levels ±2kV
EN61000-4-5 surges - levels ±2kV line to earth, ±1kV line to line
EN61000-4-8 magnetic fields - levels 30A/m at 50/60Hz
EN61000-4-11 voltage dips, interruptions
Safety Class
EMC1
RoHS
The Series OLH10K meets the requirements of EU Directive 2002/95/EC on the Restriction of use of Certain
Hazardous Substances in electrical and electronic equipment (RoHS).
1
The Series OLH10K is intended for installation as a component of a system and is designed to meet
The unit will not trip and recovers to normal operation after a disturbance as defined in SEMI F47-0706.
The EMC performance of the power supply can only be fully assessed when installed within, and as part of, the final system.
2
advanced-energy.com
HITEK POWER OLH10K SERIES
ELECTRICAL SPECIFICATIONS (CONTINEUD)
Input Current
OLH10K
OLH10KC
OLH10KE
Voltage Ripple
Voltage Mode
Current Mode
Voltage Regulation
Line
Load
Current Regulation
Line
Load
Cooling
Converter
The unit utilises forced air cooling. Air is drawn in via the front panel slotted opening and through side panel
vents. Ensure that within the rack there is a free air opening with a minimum effective area of 195cm
2
directly
in front of the unit front panel slots. An additional free air opening with a minimum effective area of 195m
2
is
required for the side vents. Air flow from this additional free air opening to the side vents of the power converter
must not be restricted. The expected air flow for each opening is approximately 50 Litres per second. The
maximum temperature of the air entering the units must not exceed 40°C (104°F).
The unit can dissipate up to 1kW, therefore provision must be made to extract the exhaust air from the rack in
order to prevent possible overheating.
HV Unit
The HV Unit may be mounted in any orientation, but at least 150mm of free space should be allowed around
the HV base for air intake/exhaust from the fans. The side panel grilles must not be obstructed. The maximum
temperature of air entering the HV base must not exceed 40°C (104°F).
Adequate clearance must be allowed around the HV discs to take account of the high voltage output.
The HV unit can dissipate up to 1kW, therefore provision must be made to extract air/cool the oil in the HV
enclosure in order to prevent possible overheating.
Less than 0.5% of rated current for a ±10% change in line voltage
Less than 0.5% of rated current for 0 to 100% change in output voltage
Less than 0.01% +0.5V change in output voltage for a 10% change in line voltage
Less than 0.01% +0.5V change in output voltage for 0 to 100% change in load current
Less than 0.1% of rated voltage +2V, peak to peak or less than 0.02% of rated voltage +1V, rms
Less than 0.5% of rated voltage peak to peak or less than 0.1% of rated voltage rms
Less than 36A per phase
Less than 22A per phase
Less than 22A per phase
advanced-energy.com
3
HITEK POWER OLH10K SERIES
MECHANICAL SPECIFICATIONS
Please contact the Sales Team for 400kV and 500kV mechanical outline details and weights.
Dimensions
Connections
Mains
Safety Earth
HV Output
Front Panel
60kV-300kV models - see outline drawings attached
All connections are mounted on the rear panel
Harting Han C (mating part provided)
M6 stud on both the converter and HV unit
Direct connection to the top of the HV unit
Stoving enamel trimite full gloss S60/9 colour blue RAL5011 as standard
Blank front panel available to order (see below)
Weight
60kV-300kV Converter
60kV-300kV Stacks
27kg
Output Voltage Variant
60 kV
80 kV
100 kV
120 kV
140 kV
160 kV
180 kV
200 kV
300 kV
HV Stack Weight
31 kg
36 kg
41 kg
46 kg
51 kg
56 kg
61 kg
66 kg
91 kg
4
advanced-energy.com
Series OLH10K
HITEK POWER OLH10K SERIES
10kW HIGH VOLTAGE POWER SUPPLIES
Series OLH10K
MECHANICAL SPECIFICATIONS (CONTINEUD)
10kW HIGH VOLTAGE POWER SUPPLIES
45.0 [1.8]
429.8 [16.9]
MAINS IN
H.V. OUT
102.4 [4.0]
EARTH STUD
92.1 [3.6]
12.7 [0.5]
OUTPUT kV
60
80
100
120
140
160
180
200
300
DIM 'A' NOMINAL
229.2 [9.0]
280.1 [11.0]
331.0 [13.0]
381.9 [15.0]
432.8 [17.0]
483.7 [19.0]
534.6 [21.0]
585.5 [23.1]
840.0 [33.1]
457.2 [18.0]
92.1 [3.6]
47.2 [1.9]
177.8 [7.0]
177.8 [7.0]
38.1 [1.5]
515.5 [20.3]
92.1 [3.6]
300.0 [11.8] DIA
410.0 [16.1] DIA
92.1 [3.6]
DIM 'A' HEIGHT INCLUDING FIXINGS
105.0 [4.1]
AIRFLOW
43.0 [1.7]
Design developments may result in specification changes
132.6 [5.2]
Drawing dimensions are in mm (inches)
Design developments may result in specification changes
Drawing dimensions are in mm (inches)
105.8 [4.2]
AIR
IN
192.0 [7.6]
270.0 [10.6]
109.6 [4.3]
482.6 [19.0]
234.3 [9.2]
10.0 [0.4]
INPUT
CONNECTOR
77.6 [3.1]
FAN
76.8 [3.0]
283.2 [11.1]
93.6 [3.7]
These component power supplies meet the requirements of EC Directive 2006/95/EC (LVD)
.
w w w. h i t e k p o w e r. c o m
w w w. h i t e k p o w e r. c o m
advanced-energy.com
10.9 [0.4]
40.0 [1.6]
50.8 [2.0]
38.1 [1.5]
FRONT
COVER
88.9 [3.5]
88.9 [3.5]
177.8 [7.0]
38.1 [1.5]
M4 FIXINGS
ALL DIMENSIONS -
MILLIMETRES [INCHES]
453.6 [17.9]
HOLE
8.7
10 POSITIONS
355.6 [14.0]
38.1 [1.5]
5