RP
RP327 Series
RP327
3 PHASE TO 250A
BOOKSHELF DESIGN
ROHS COMPLIANT
RADIUS POWER
Your Power Partner
Bookself, 3-Phase Delta Dual Stage Power Line Filter
SPECIFICATIONS
Operating Freq.
Usable Freq.
Max. Operating Voltage
Ambient Temperature
Climatic Category
Hipot Rating (L-G)
Terminals (-T)
:
:
:
:
:
:
:
50/60Hz
DC - 400Hz
480V +10%
-25 to 50C
25/100/21
3500VDC
S: 7/16/30/42/55A (M5)
75/100A (M6)
130/180/250A (M10)
UR, CSA, EN60939
LEAKAGE CURRENT
Y-cap, nF
0
10
100
1000
2000
mA,
480V/60Hz
0
0.1
1
10
20
Safety Approvals
:
PART NUMBER/ ORDERING
RP327
-X
-Y
(Amps) (Ycap, nF)
7
16
30
42
55
75
100
130
180
250
0
10
100
1000
2000
-T
S
Weight
LBS (KG)
Typ.
5.0 (2.3)
7.0 (3.2)
10.0 (4.5)
13.3 (5.9)
13.5 (6.1)
14.0 (6.4)
18.0 (8.2)
27.0 (12.3)
27.5 (12.5)
31.0 (14.1)
SCHEMATIC
Note:
Use any combination of -Y with any -X (Amps) rating
e.g. RP327-180-100-S (180 Amps with 100nF Ycap)
www.radiuspower.com
Reference purposes only.
Specifications are subject to change.
Consult factory to verify specifications.
Engineering Assistance: engg@radiuspower.com
Sales:sales@radiuspower.com
63
RP
RP327
Typical Insertion Loss, dB (50/50ohm)
7Amp
RADIUS POWER
Your Power Partner
Mechanical Drawings
16Amp
7/16 Amp
FREQ (MHz)
CM (dB)
DM (dB)
.15
65
55
.5
70
70
1
70
70
10
55
70
30
40
60
30 Amp
FREQ (MHz)
CM (dB)
DM (dB)
.15
65
60
.5
70
70
1
70
70
10
50
70
30
30
50
30Amp
TYPICAL TOLERANCE: +/-0.02 (0.50)
Reference purposes only.
Specifications are subject to change.
Consult factory to verify specifications.
www.radiuspower.com
64
Engineering Assistance: engg@radiuspower.com
Sales:sales@radiuspower.com
RP
RP327
Typical Insertion Loss, dB (50/50ohm)
42Amp
RADIUS POWER
Your Power Partner
Mechanical Dimensions
42 Amp
FREQ (MHz)
CM (dB)
DM (dB)
.15
70
55
.5
70
70
1
70
70
10
70
65
30
50
50
55Amp
55 Amp
FREQ (MHz)
CM (dB)
DM (dB)
.15
70
55
.5
70
70
1
70
70
10
70
65
30
50
50
75 Amp
FREQ (MHz)
CM (dB)
DM (dB)
.15
65
40
.5
70
70
1
70
70
10
60
65
30
30
40
75Amp
TYPICAL TOLERANCE: +/-0.02 (0.50)
Reference purposes only.
Specifications are subject to change.
Consult factory to verify specifications.
www.radiuspower.com
65
Engineering Assistance: engg@radiuspower.com
Sales:sales@radiuspower.com
RP
RP327
Typical Insertion Loss, dB (50/50ohm)
100Amp
RADIUS POWER
Your Power Partner
Mechanical Dimensions
100 Amp
FREQ (MHz)
CM (dB)
DM (dB)
.15
65
40
.5
70
70
1
70
70
10
60
65
30
30
40
130Amp
130 Amp
FREQ (MHz)
CM (dB)
DM (dB)
.15
52
45
.5
70
70
1
65
70
10
40
60
30
25
50
TYPICAL TOLERANCE: +/-0.02 (0.50)
www.radiuspower.com
Reference purposes only.
Specifications are subject to change.
Consult factory to verify specifications.
Engineering Assistance: engg@radiuspower.com
Sales:sales@radiuspower.com
66
RP
RP327
Typical Insertion Loss, dB (50/50ohm)
180Amp
RADIUS POWER
Your Power Partner
Mechanical Dimensions
180 Amp
FREQ (MHz)
CM (dB)
DM (dB)
.15
55
55
.5
70
70
1
70
60
10
40
45
30
20
25
250Amp
250 Amp
FREQ (MHz)
CM (dB)
DM (dB)
.15
65
65
.5
70
65
1
70
60
10
40
45
30
26
38
TYPICAL TOLERANCE: +/-0.02 (0.50)
www.radiuspower.com
Reference purposes only.
Specifications are subject to change.
Consult factory to verify specifications.
Engineering Assistance: engg@radiuspower.com
Sales:sales@radiuspower.com
67