https://www.phoenixcontact.com/us/products/1694790
Sensor/Actuator cable - SAC-3P-10,0-PUR/M12FS-2L - 1694790
Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's
documentation. Our General Terms of Use for Downloads are valid
(http://phoenixcontact.com/download)
Sensor/Actuator cable, 3-position, PUR halogen-free, black-gray RAL 7021, free cable end, on Socket straight
M12, A-coded, with 2 LEDs, Cable length: 10 m
Product Features
Easy and safe: 100% electrically tested plug-in components
Our standard: robust halogen-free PUR cable
Convenient: increased machine availability thanks to quick and easy diagnostics
Key Commercial Data
Packing unit
Weight per Piece (excluding packing)
Custom tariff number
Country of origin
1 pc
264.7 g
85444290
Poland
Technical data
Dimensions
Length of cable
Stripping length of the free conductor end
10 m
50 mm
Ambient conditions
Ambient temperature (operation)
Degree of protection
-25 °C ... 90 °C (Plug / socket)
IP65
IP67
IP68
General
Rated current at 40°C
Rated voltage
Number of positions
4A
24 V
3
12/14/2015 Page 1 / 5
https://www.phoenixcontact.com/us/products/1694790
Sensor/Actuator cable - SAC-3P-10,0-PUR/M12FS-2L - 1694790
Technical data
General
Insulation resistance
Coding
Standards/regulations
Status display
Protective circuit/component
Overvoltage category
Pollution degree
Insertion/withdrawal cycles
Torque
≥ 100 MΩ
A - standard
M12 connector IEC 61076-2-101
2 LEDs
Unwired
II
3
≥ 100
0.4 Nm (M12 connector)
Material
Flammability rating according to UL 94
Contact material
Contact surface material
Contact carrier material
Material of grip body
Material, knurls
Sealing material
HB
CuSn
Ni/Au
TPU GF
TPU, hardly inflammable, self-extinguishing
Zinc die-cast, nickel-plated
NBR
Standards and Regulations
Standard designation
Standards/regulations
Flammability rating according to UL 94
M12 connector
IEC 61076-2-101
HB
Cable
Cable type
Cable type (abbreviation)
Cable abbreviation
UL AWM style
Conductor cross section
AWG signal line
Conductor structure signal line
Core diameter including insulation
Thickness, insulation
Wire colors
Overall twist
External sheath, color
Outer sheath thickness
External cable diameter D
PUR halogen-free black
PUR
Li9Y11Y
20549
3x 0.34 mm² (signal line)
22
42x 0.10 mm
1.27 mm ±0.02 mm (signal line)
≥ 0.21 mm (Core insulation)
brown, blue, black
3 wires, twisted
black-gray RAL 7021
approx. 0.8 mm
4.4 mm ±0.15 mm
12/14/2015 Page 2 / 5
https://www.phoenixcontact.com/us/products/1694790
Sensor/Actuator cable - SAC-3P-10,0-PUR/M12FS-2L - 1694790
Technical data
Cable
Smallest bending radius, fixed installation
Smallest bending radius, movable installation
Number of bending cycles
Bending radius
Traversing path
Traversing rate
Acceleration
Cable weight
Outer sheath, material
Material conductor insulation
Conductor material
Insulation resistance
Conductor resistance
Nominal voltage, cable
Test voltage, cable
Special properties
22 mm
44 mm
4000000
44 mm
10 m
3 m/s
10 m/s²
26 kg/km
PUR
PP
Bare Cu litz wires
≥ 100 GΩ*km (at 20 °C)
max. 58 Ω/km (at 20 °C)
≤ 300 V
≥ 3000 V
Flexible cable conduit capable
Silicone-free
Free of substances which would hinder coating with paint or varnish
Flame resistance
Halogen-free
Resistance to oil
Other resistance
in accordance with DIN UL-Style 20549
in accordance with DIN VDE 0472 part 815
in accordance with DIN EN 60811-2-1
Highly resistant to acids, alkaline solutions and solvents
hydrolysis and microbe resistant
partly UV-resistant in accordance with DIN EN ISO 4892-2-A
Ambient temperature (operation)
-40 °C ... 80 °C (cable, fixed installation)
-25 °C ... 80 °C (cable, flexible installation)
Classifications
eCl@ss
eCl@ss 4.0
eCl@ss 4.1
eCl@ss 5.0
eCl@ss 5.1
eCl@ss 6.0
eCl@ss 7.0
eCl@ss 8.0
27060306
27060306
27061801
27061801
27061801
27061801
27279218
12/14/2015 Page 3 / 5
https://www.phoenixcontact.com/us/products/1694790
Sensor/Actuator cable - SAC-3P-10,0-PUR/M12FS-2L - 1694790
Classifications
ETIM
ETIM 2.0
ETIM 3.0
ETIM 4.0
ETIM 5.0
EC000830
EC001855
EC001855
EC001855
UNSPSC
UNSPSC 6.01
UNSPSC 7.0901
UNSPSC 11
UNSPSC 12.01
UNSPSC 13.2
31251501
31251501
31251501
31251501
31251501
Approvals
Approvals
Approvals
UL Listed / cUL Listed / EAC / cULus Listed
Ex Approvals
Approvals submitted
Approval details
UL Listed
Nominal current IN
Nominal voltage UN
4A
24 V
12/14/2015 Page 4 / 5
https://www.phoenixcontact.com/us/products/1694790
Sensor/Actuator cable - SAC-3P-10,0-PUR/M12FS-2L - 1694790
Approvals
cUL Listed
Nominal current IN
Nominal voltage UN
4A
24 V
EAC
cULus Listed
Drawings
Schematic diagram
3
4
Cable cross section
1
Pin assignment M12 socket, 3-pos., A-coded, view female side
PUR halogen-free black [PUR]
Circuit diagram
1
BN
Dimensional drawing
44,5
4
GN
YE
BK
Ø14,8
M12
Ø12
3
BU
Contact assignment of M12 sockets with LED
Socket M12 x 1, straight, with LED
Phoenix Contact 2015 © - all rights reserved
http://www.phoenixcontact.com
12/14/2015 Page 5 / 5