https://www.phoenixcontact.com/us/products/2800531
Lightning/surge arrester type 1/2 - PWT 100-800AC-FM - 2800531
Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's
documentation. Our General Terms of Use for Downloads are valid
(http://phoenixcontact.com/download)
Lightning/surge arrester, according to type 1/2 / class I/II, for 3-phase power supply networks with combined PE
and N installed in one conductor (L1, L2, L3, PEN).
Product Features
Use in harsh industrial environments
Very high TOV resistance
Universal solution for various network types
Meets installation requirements according to CLC/TS 50539-22
Meets Lightning Protection Level I
Free of leakage current/no line follow current
Encapsulated, non-extinguishing
Local optical status indication
Multi-stage status monitoring via remote indication contact
Type 1/2 arrester based on a varistor
Packing unit
Custom tariff number
Country of origin
1 pc
85363010
Germany
Key commercial data
Technical data
Dimensions
Height
Width
Depth
191 mm
176 mm
280 mm
Ambient conditions
Degree of protection
IP20
09/10/2014 Page 1 / 9
https://www.phoenixcontact.com/us/products/2800531
Lightning/surge arrester type 1/2 - PWT 100-800AC-FM - 2800531
Technical data
Ambient conditions
Ambient temperature (operation)
Ambient temperature (storage/transport)
Altitude
Permissible humidity (operation)
Shock (operation)
Vibration (operation)
-40 °C ... 80 °C
-40 °C ... 55 °C (serial through wiring ≥ 35 mm²)
-40 °C ... 80 °C
≤ 4000 m (NN)
5 % ... 95 %
25g
5g (10 ... 500 Hz)
General
IEC power supply system
Housing material
Inflammability class according to UL 94
Standards for air and creepage distances
Mounting type
Type
Number of positions
Surge protection fault message
Direction of action
TN-C
IT
Die-cast aluminum, salt water resistant
V2
DIN EN 60664-1
EN 61643-11
Screw mounting
Mounting plate
3
Optical, remote indicator contact
3L-PEN
Protective circuit
IEC test classification
EN type
Lightning protection class
Nominal voltage U
N
Maximum continuous operating voltage U
C
(L-PE)
U
T
(TOV-proof)
Nominal frequency f
N
Rated load current I
L
Residual current I
PE
Standby power consumption P
C
Max. discharge current I
max
(8/20) µs maximum (L-PE)
Nominal discharge current I
n
(8/20) µs (L-PE)
Impulse discharge current (10/350) µs charge
I / II
T1 / T2
T1 / T2
I
690 V AC
800 V AC
1500 V AC (5 sec.)
1960 V AC (200 ms)
50 Hz
60 Hz
150 A (Serial through wiring with 50 mm²)
≤ 20 µA
≤ 16 mVA
100 kA (per position)
35 kA (per position)
17.5 As
09/10/2014 Page 2 / 9
https://www.phoenixcontact.com/us/products/2800531
Lightning/surge arrester type 1/2 - PWT 100-800AC-FM - 2800531
Technical data
Protective circuit
Impulse discharge current (10/350)½µs, specific energy
Impulse discharge current (10/350)½µs, peak value l
imp
Front of wave sparkover voltage at 6 kV (1.2/50) µs (L-PE)
Voltage protection level U
p
(L-PE)
Residual voltage (L-PE)
305 kJ/Ω
35 kA (per position)
≤ 4.5 kV
≤ 4.5 kV
≤ 2.7 kV
≤ 2.5 kV (at 20 kA)
≤ 2.3 kV (at 10 kA)
≤ 2.2 kV (at 5 kA)
≤ 2.1 kV (at 3 kA)
Response time (L-PE)
Max. backup fuse with branch wiring
Max. backup fuse with V-type through wiring
Short-circuit resistance I
P
with max. backup fuse (effective)
Follow current quenching capacity If (L-PEN)
≤ 100 ns
400 A (gG; 2 x 50 mm²)
800 A (aR (only up to limp = 25 kA))
125 A (gG; ≥ 35 mm²)
50 kA
50 kA
Connection, protective circuit
Connection name
Connection method
Screw thread
Tightening torque
Stripping length
Conductor cross section stranded min.
Conductor cross section stranded max.
Conductor cross section solid min.
Conductor cross section solid max.
AWG conductor cross section
Connection name
Connection method
Screw thread
Tightening torque
Conductor cross section stranded min.
Conductor cross section stranded max.
Double terminal point
Screw connection
M6
8.5 Nm
75 lb
f
-in. (UL)
24 mm
16 mm²
50 mm²
16 mm²
50 mm²
6 ... 1/0
6 ... 1/0 (UL)
PE conductor connection
Ring cable lug
M10 hexagonal head screw (ISO 4017/DIN 933)
M10
20 Nm
175 lb
f
-in. (UL)
16 mm²
95 mm²
09/10/2014 Page 3 / 9
https://www.phoenixcontact.com/us/products/2800531
Lightning/surge arrester type 1/2 - PWT 100-800AC-FM - 2800531
Technical data
Connection, protective circuit
Conductor cross section solid min.
Conductor cross section solid max.
AWG conductor cross section
16 mm²
95 mm²
6 ... 3/0
3/0 (UL)
Remote indicator contact
Connection name
Switching function
Screw thread
Tightening torque
Stripping length
Conductor cross section stranded min.
Conductor cross section stranded max.
Conductor cross section solid min.
Conductor cross section solid max.
AWG conductor cross section
Maximum operating voltage U
max.
AC
Maximum operating voltage U
max
DC
Max. operating current I
max
Remote indicator contact
N/C contact, 1-pos.
M3
0.55 Nm
7 lb
f
-in. ... 5 lb
f
-in. (UL)
7 mm
0.2 mm²
2.5 mm²
0.2 mm²
2.5 mm²
24 ... 12
24 ... 12 (UL)
30 V AC
30 V DC
1.5 A AC
1.5 A DC
Standards and Regulations
Standards/regulations
IEC 61643-11 2011
EN 61643-11 2012
Classifications
eCl@ss
eCl@ss 4.0
eCl@ss 4.1
eCl@ss 5.0
eCl@ss 5.1
eCl@ss 6.0
eCl@ss 7.0
eCl@ss 8.0
27140201
27140201
27140201
27140201
27140201
27140201
27140201
09/10/2014 Page 4 / 9
https://www.phoenixcontact.com/us/products/2800531
Lightning/surge arrester type 1/2 - PWT 100-800AC-FM - 2800531
Classifications
ETIM
ETIM 2.0
ETIM 3.0
ETIM 4.0
ETIM 5.0
EC000381
EC000381
EC000381
EC000381
UNSPSC
UNSPSC 6.01
UNSPSC 7.0901
UNSPSC 11
UNSPSC 12.01
UNSPSC 13.2
30212010
39121610
39121610
39121610
39121620
Approvals
Approvals
Approvals
IECEE CB Scheme / UL Recognized / KEMA-KEUR / ÖVE / cUL Recognized / CCA / cULus Recognized
Ex Approvals
Approvals submitted
Approval details
IECEE CB Scheme
UL Recognized
KEMA-KEUR
09/10/2014 Page 5 / 9