Part Number:
2505PTZ
PTZ, RG-59 #20, #18-1pr, #16-2c, Shielded, CM, Siamese
Product Description
PTZ (CCTV + Control + Power) Cable, Rated-CM, 1-RG59 20 AWG solid bare copper with foam polyolefin, 95% bare copper braid, 1-18 AWG stranded bare
copper pair with PVC insulation and Beldfoil® shield, 2-16 AWG stranded bare copper conductors with PVC insulation, Siamese with PVC jacket, Aluminum
interlocking armor
Technical Specifications
Physical Characteristics (Overall)
Conductor
Element
Coax
Shielded Pair
AWG Stranding
20
18
Solid
7x26
19x29
Material
Nominal Diameter No. of Conductors No. of Pairs No. of Coax
1
1
2
5
20 AWG
1
BC - Bare Copper 0.032 in
BC - Bare Copper
BC - Bare Copper
Power conductors 16
Conductor Count:
Conductor Size:
Insulation
Material
Nominal Diameter Nominal Wall Thickness
Gas-injected FHDPE - Foam High Density Polyethylene 0.145 in
PP - Polypropylene
PP - Polypropylene
Color Chart
Number
Coax core
Shielded pair
Power conductors
Coax jacket
Color
Natural
Red and Black
Red and Black
Black
0.008 in
0.008 in
Shielded ppair jacket Blue
Power jacket
Color Chart 4
Number Color
1
1
1
Black
Gray
White
White
Inner Shield Material
Type
Braid
Tape
Unshielded
Outer Shield Material
Drainwire Construction n x D
7x28 mm
Note:
Outer Jacket Material
Polyester
Material
BC - Bare Copper
Material Trade Name
Coverage [%] Drainwire AWG Drainwire Construction n x D
93.0 %
24
7x32
Aluminum Foil-Polyester Tape Beldfoil® with shorting fold 100.0 %
Material
Nominal Diameter
PVC - Polyvinyl Chloride 0.165 in
PVC - Polyvinyl Chloride 0.496 in
Unjacketed
Construction and Dimensions
Armor
Type of Armor
Interlocked
Material
Diameter over Armoring
Aluminum 0.633 in
Electrical Characteristics
Conductor DCR
Element
Coax
Shielded pair
Nominal Conductor DCR Nominal Conductor DCR Conductor Resistance Nominal Inner Shield DCR
10 Ohm/1000ft
6.5 Ohm/1000ft
10 Ohm/1000ft
4.2 Ohm/1000ft
3.5 Ohm/1000ft
Power Conductors 4.2 Ohm/1000ft
Capacitance
Nom. Capacitance Conductor to
Conductor
Nom. Capacitance Conductor to Other Conductor to Shield Nom. Capacitance Conductor to Shield
16.3 pF/ft
53 pF/ft
Inductance
Nominal Inductance
0.097 µH/ft
0.145 µH/ft
Impedance
Nominal Characteristic Impedance
75 Ohm
High Frequency (Nominal/Typical)
Frequency [MHz] Nom. Insertion Loss
1 MHz
5 MHz
10 MHz
50 MHz
100 MHz
200 MHz
400 MHz
700 MHz
900 MHz
1000 MHz
Delay
Max. Delay Skew Nominal Delay Nominal Velocity of Propagation (VP) [%]
83 ns/100m
Current
Max. Recommended Current [A]
5 Amps per conductor @ 25°C
Per conductor @ 25°C: 5 A
Voltage
UL Voltage Rating
300 V RMS
Mated Connection
Min. Return Loss Belden** (dB)
24.5 dB
1.22 ns/ft
83 %
0.3 dB/100ft
0.65 dB/100ft
0.9 dB/100ft
1.9 dB/100ft
2.6 dB/100ft
3.6 dB/100ft
5 dB/100ft
7 dB/100ft
8 dB/100ft
8.5 dB/100ft
95.5 pF/ft
Temperature Range
Operating Temp Range:
Separation Temp Range:
-10°C To +75°C
0°C To +75°C
Mechanical Characteristics
Bulk Cable Weight:
Max Recommended Pulling Tension:
Min Bend Radius/Minor Axis:
142 lbs/1000ft
210 lbs
9.5 in
Standards
NEC Articles:
NEC/(UL) Specification:
CEC/C(UL) Specification:
RG Type:
Other Standards:
800
CMG
CMG
59/U Type
Coax: RG 59/U
Applicable Environmental and Other Programs
EU Directive 2000/53/EC (ELV):
EU Directive 2003/11/EC (BFR):
EU Directive 2011/65/EU (ROHS II):
EU Directive 2012/19/EU (WEEE):
EU Directive 2015/863/EU:
EU Directive Compliance:
EU CE Mark:
EU RoHS Compliance Date (yyyy-mm-dd):
CA Prop 65 (CJ for Wire & Cable):
MII Order #39 (China RoHS):
Yes
Yes
Yes
Yes
Yes
Yes
Yes
2007-06-08
Yes
Yes
Suitability
Suitability - Indoor:
Yes
Flammability, LS0H, Toxicity Testing
UL Flammability:
UL voltage rating:
UL1685 Vertical Tray Flame Test
300 V RMS
Plenum/Non-Plenum
Plenum (Y/N):
No
Part Number
Variants
Item #
Color Footnote
C
C - CRATE REEL PUT-UP.
2505PTZ 0001000 Black
Footnote:
© 2018 Belden, Inc
All Rights Reserved.
Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications described here in are subject to error or omission and to change without
notice, and the listing of such information and specifications does not ensure product availability.
Belden provides the information and specifications herein on an "ASIS" basis, with no representations or warranties, whether express, statutory or implied. In no event will Belden be liable for any damages
(including consequential, indirect, incidental, special, punitive, or exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract,
negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein.
All sales of Belden products are subject to Belden's standard terms and conditions of sale.
Belden believes this product to be in compliance with all applicable environmental programs as listed in the data sheet. The information provided is correct to the best of Belden's knowledge, information and belief
at the date of its publication. This information is designed only as a general guide for the safe handling, storage, and any other operation of the product itself or the one that it becomes a part of. The Product
Disclosure is not to be considered a warranty or quality specification. Regulatory information is for guidance purposes only. Product users are responsible for determining the applicability of legislation and
regulations based on their individual usage of the product.