Thermal-Magnetic Circuit Breaker 2210-T2...
Description
One, two and three pole thermal-magnetic circuit breakers with trip-free
mechanism and toggle actuation (S-type TM CBE to EN 60934/IEC 934).
Featuring a combi-foot design for both symmetric and asymmetric rail
mounting. Available with auxiliary contact (1 x N/O or 1 x N/C) for status
signalling. Two and three pole models are internally linked to ensure that
both/all poles trip in the event of an overload on one pole, even if the
actuator is held in the ON position. This CBE can be supplied in current
ratings up to 32 A with a choice of characteristic curves. All screw
terminals are recessed for safety. Approved to CBE standard EN 60934
(IEC 60934).
Typical applications
Process control equipment, robotics, machine tool control,
communications systems, instrumentation.
1-pole
2210-T2..
1
3-pole
Technical data
For further details please see chapter: Technical Information
Voltage rating
AC 250 V; 3 AC 433 V (50/60 Hz); DC 65 V
(UL: AC 277/480 V; DC 65 V)
Current rating range
0.1...32 A for curves M1, T1
0.1...16 A for curves F1, F2
Auxiliary circuit
1 A, AC 240 V / DC 65 V, resistive
(min. 10 V / 10 mA)
Typical life
3 AC 433 V; AC 250 V: 0.1...25 A
10,000 operations at 1 x I
N
, inductive
DC 65 V:
0.1...32 A
10,000 operations at 1 x I
N
, inductive
3 AC 433 V; AC 250 V: 32 A
6,000 operations at 1 x I
N
, resistive
Ambient temperature
-30...+60 °C (-22...+140 °F) T 60
Insulation co-ordination
rated impulse
pollution
(IEC 60664 and 60664 A) withstand voltage
degree
2.5 kV
2
reinforced insulation in operating area
Dielectric strength
(IEC 60664 and 60664A)
test voltage
operating area
AC 3,000 V
main/aux. circuit
AC 3,000 V
pole/pole
AC 1,500 V
Insulation resistance
> 100 MΩ (DC 500 V)
Interrupting capacity I
cn
0.1...5 A
400 A
6...32 A
800 A
curves F1, F2, M1, T1: 0.1...16 A 2,500 A (at DC 32 V)
Interrupting capacity (UL 1077)
I
N
0.1...16 A
20...25 A
Preferred types
Preferred types
1-pole
2210-T210-K0M1-H121-
2-pole
2210-T220-K0M1-H221-
Standard current ratings (A)
0.5 1
x
x
2
x
3
x
4
x
5
x
6
x
8 10 16 20
x
x
x
x
0.5 1
2
x
3
4
x
5
6
x
8 10 16 20
x
x
x
Ordering information
Type No.
2210
single and multipole thermal-magnetic circuit breaker
Mounting
T
rail mounting
Actuator design
2
toggle
Number of poles
1
single pole protected
2
2-pole protected
3
3-pole protected
Accessories
0
without accessories
Terminal design (main contacts)
K0
screw terminals
Characteristic curve
F1
fast acting: therm.1.01-1.4xI
N
;
magn.2-4xI
N
DC (DC only)
F2
fast acting: therm.1.01-1.4xI
N
;
magn.3,5-6,5xI
N
AC/4,5-8,5xI
N
DC
M1
standard delay: therm. 1.01-1.4xI
N
;
magn. 6-12xI
N
AC, 7.8-15.6xI
N
DC
T1
delayed: therm. 1.01-1.4xI
N
; magn. 10-20xI
N
AC
Auxiliary contact design
H
without intermediate position
Auxiliary contacts
1
with auxiliary contacts
2
auxiliary contacts on pole 1 only
(multipole devices)
Auxiliary contact function (see diagrams)
2
1 N/O contact
3
1 N/C contact
Auxiliary contact - terminal design
1
screw terminals
Current ratings
0.1...32 A
2210 - T 2 1 0 - K0 M1- H 1 2 1 - 10 A
ordering example
AC 277 V
1-pole
AC 277/480 V
2-/3-pole
DC 65 V
Degree of protection
(IEC 60529/DIN 40050)
Vibration curves F1, F2:
curves M1, T1:
5,000 A
5,000 A
2,000 A
2,000 A
2,000 A
2,000 A
operating area IP30
terminal area IP20
3 g (57-500 Hz), ± 0.23 mm (10-57 Hz)
5 g (57-500 Hz), ± 0.38 mm (10-57 Hz)
to IEC 60068-2-6, test Fc
10 frequency cycles/axis
Shock
curves F1, F2: 25 g (11 ms), directions 1, 2, 3, 4, 5
10 g (11 ms), direction 6
curves M1, T1: 25 g (11 ms), directions 1, 2, 3, 4, 5
20 g (11 ms), direction 6
to IEC 60068-2-27, test Ea
Corrosion
96 hours at 5 % salt mist
to IEC 60068-2-11, test Ka
Humidity
240 hours at 95 % RH
to IEC 60068-2-78, test Cab
Mass
approx. 60 g per pole
1812
www.e-t-a.de
1
IAR下,出现warning:***ERROR**:unable to start execution 0x00000004
IAR环境下,调试已有hello例程,点击“download and debug”后,programming flash memory时候出现 “Warning:***ERROR**:unable to start execution 0x00000004” 使用的是lm3s9b92 ......
jessicadhit 微控制器 MCU
直播 FAQ|物联网时代的典型应用
直播详情:将至已至,物联网时代的典型应用 直播主题1:深入浅出低功耗 MCU 直播讲师:段伟 直播主题2:5G 加速物联网应用和数字转型 直播讲师:黎伟昌 直播FAQ摘录 ......
EEWORLD社区 单片机
请教如何通过按键控制切换输入法??
各位好: 目前我的PDA上有一个软键盘和一个汉王的手写输入法 默认情况下都是在任务栏中,通过触摸屏点击选择的 可是现在要用一个键盘来控制切换输入法, 请问各位高手需要怎么才能实现 ......
ilycjf 嵌入式系统
EEWORLD大学堂----nxp
nxp:https://training.eeworld.com.cn/course/4138...
w562601331 单片机
IAR+EK_SMT32F调试警告信
...
wenhuocai stm32/stm8
直流电路分析
T(℃)↑→IC↑→UE ↑→UBE↓(UB基本不变)→ IB ↓→ IC↓ IB怎么就减小 不明白有人说是三极管的特性 我不明白翻书貌似怎么也找不到这个特性 ...
nt06 模拟电子

 
EEWorld订阅号

 
EEWorld服务号

 
汽车开发圈

 
机器人开发圈

About Us 关于我们 客户服务 联系方式 器件索引 网站地图 最新更新 手机版

站点相关: 大学堂 TI培训 Datasheet 电子工程 索引文件: 307  1318  1441  2211  33  18  14  46  4  25 

器件索引   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z

北京市海淀区中关村大街18号B座15层1530室 电话:(010)82350740 邮编:100190

电子工程世界版权所有 京B2-20211791 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号 Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved