Product specifications
Core
EQ30 + PLT30/20/3
Effective parameters
Symbol
∑(I/A)
Ve
Le
Ae
Amin
m
m
Parameter
core factor (C1)
effective volume
effective length
effective area
minimum area
EQ30
PLT30/20/3
Value
0.335
3910
36.2
108
95
≈ 13.2
≈ 7.6
Unit
mm⁻¹
mm³
mm
mm²
mm²
g/pcs
g/pcs
Dimensions for product: EQ30
Symbol
A
B
C
D2
D3
E
F
Nom
30.00
20.00
19.45
26.00
11.00
8.00
5.30
Tol +
0.40
0.30
0.40
0.40
0.20
0.15
0.20
Tol -
0.40
0.30
0.40
0.40
0.20
0.15
0.20
Max
30.40
20.30
19.85
26.40
11.20
8.15
5.50
Min
29.60
19.70
19.05
25.60
10.80
7.85
5.10
Unit
mm
mm
mm
mm
mm
mm
mm
Dimensions for product: PLT30/20/3
Symbol
A
Nom
30.00
Tol +
0.40
Tol -
0.40
Max
30.40
Min
29.60
Unit
mm
2016
Product specifications
Core
EQ30 + PLT30/20/3
Dimensions for product: PLT30/20/3
Nom
20.00
2.70
Tol +
0.30
0.10
Tol -
0.30
0.10
Max
20.30
2.80
Min
19.70
2.60
Unit
mm
mm
Symbol
B
C
Inductance factor
Material
3C95
3C96
3F36
3F4
3F46
Value
6630
4900
4000
2400
2500
Tol +
25%
25%
25%
25%
25%
Tol -
25%
25%
25%
25%
25%
Unit
nH/turns²
nH/turns²
nH/turns²
nH/turns²
nH/turns²
Power loss: 3C95
Measuring conditions
100 kHz
100 kHz
200 mT
200 mT
100 ºC
25 ºC
Power loss: 3C96
Measuring conditions
100 kHz
400 kHz
200 mT
50 mT
100 ºC
100 ºC
Power loss: 3F36
Measuring conditions
500 kHz
500 kHz
50 mT
100 mT
100 ºC
100 ºC
Power loss: 3F4
Measuring conditions
1000 kHz
3000 kHz
30 mT
10 mT
100 ºC
100 ºC
Power loss: 3F46
Measuring conditions
1000 kHz
3000 kHz
50 mT
10 mT
100 ºC
100 ºC
Max
1.600
0.760
Unit
W/set
W/set
Max
1.200
2.000
Unit
W/set
W/set
Max
0.590
4.500
Unit
W/set
W/set
Max
1.800
0.700
Unit
W/set
W/set
Max
1.900
2.000
Unit
W/set
W/set
Bsat
Measuring conditions
25 kHz
25 kHz
25 kHz
25 kHz
25 kHz
250 A/m
250 A/m
250 A/m
250 A/m
250 A/m
100 ºC
100 ºC
100 ºC
100 ºC
100 ºC
Material
3C95
3C96
3F36
3F4
3F46
Min
330
340
340
330
330
Unit
mT
mT
mT
mT
mT
Accessories
Ordering name
Description
Ordering code
2016
Product specifications
Core
EQ30 + PLT30/20/3
Coil former, termoset, vertical
432202107031
CSV-EQ30/16/20-1S-10P-Z
2016