Detailed Specifications & Technical Data
ENGLISH MEASUREMENT VERSION
1386LA Multi-Conductor - Media, Automation and Lighting Control
For more Information
please call
1-800-Belden1
General Description:
Lighting & Automation Cable, Rated-CL3, 2-12 AWG bare copper conductors unshielded, PVC insulation
(power), 1-18 AWG bare copper conductor unshielded, PVC insulation and 1 (data) pair 22 AWG stranded
bare copper, Polyethylene insulation, Beldfoil®shield w drain, PVC jacket.
Physical Characteristics (Overall)
Conductor
AWG:
# Conductors # Pairs AWG Stranding Conductor Material
1
1
2
22
18
12
7x30
19x30
19x25
BC - Bare Copper
BC - Bare Copper
BC - Bare Copper
5
Total Number of Conductors:
Insulation
Insulation Material:
Insulation Material
PE - Polyethylene
AWG
22
PVC - Polyvinyl Chloride 18
PVC - Polyvinyl Chloride 12
Inner Shield
Inner Shield Material:
Layer #
Inner Shield Trade Name Type Inner Shield Material
Coverage (%) Stranding Dia. (in.) Conductor Material
22 AWG Pair Beldfoil®
Inner Shield Drain Wire AWG:
AWG
24
Inner Shield Drain Wire Stranding:
Inner Shield Drain Wire Conductor Material:
7x32
TC - Tinned Copper
Tape Aluminum Foil-Polyester Tape 100
Outer Shield
Outer Shield Material:
Outer Shield Material
Unshielded
Outer Jacket
Outer Jacket Material:
Outer Jacket Material
PVC - Polyvinyl Chloride
Outer Jacket Ripcord:
No
Overall Cable
Overall Nominal Diameter:
0.450 in.
Pair
Pair Color Code Chart:
Number Color
1
2
3
Purple & White (22AWG)
Red & Black (12AWG)
Org (18AWG)
Mechanical Characteristics (Overall)
Operating Temperature Range:
Bulk Cable Weight:
Max. Recommended Pulling Tension:
Min. Bend Radius/Minor Axis:
-20°C To +60°C
123 lbs/1000 ft.
195 lbs.
4.500 in.
Page 1 of 3
09-11-2017
Detailed Specifications & Technical Data
ENGLISH MEASUREMENT VERSION
1386LA Multi-Conductor - Media, Automation and Lighting Control
Min. Bend Radius/Minor Axis:
4.500 in.
Applicable Specifications and Agency Compliance (Overall)
Applicable Standards & Environmental Programs
NEC/(UL) Specification:
CEC/C(UL) Specification:
EU Directive 2011/65/EU (ROHS II):
EU CE Mark:
EU Directive 2000/53/EC (ELV):
EU Directive 2002/95/EC (RoHS):
EU Directive 2002/96/EC (WEEE):
EU Directive 2003/11/EC (BFR):
CA Prop 65 (CJ for Wire & Cable):
MII Order #39 (China RoHS):
CL3, CM
CM
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Flame Test
UL Flame Test:
UL1581 Vertical Tray
Suitability
Suitability - Indoor:
Yes
Plenum/Non-Plenum
Plenum (Y/N):
Plenum Number:
No
1386LP
Electrical Characteristics (Overall)
Nom. Capacitance Conductor to Conductor:
Description Capacitance (pF/ft)
22 AWG Pair 14.170
Nom. Conductor DC Resistance:
Description DCR @ 20°C (Ohm/1000 ft)
22AWG
18AWG
12AWG
16.100
6.500
1.600
Max. Operating Voltage - UL:
Voltage
300 V RMS
Max. Recommended Current:
Description Current
22AWG
18AWG
12AWG
3.8 Amps per conductor @ 25°C
7.2 Amps per conductor @ 25°C
17.2 Amps per conductor @ 25°C
Notes (Overall)
Notes:
Sequential footage marking every two feet.
Put Ups and Colors:
Item #
1386LA 2041000
1386LA 204250
1386LA 204500
Putup
1,000 FT
250 FT
500 FT
Ship Weight
131.000 LB
35.750 LB
70.500 LB
Color
BLUE, LIGHT/WHITE
BLUE, LIGHT/WHITE
BLUE, LIGHT/WHITE
Notes
Item Desc
2#12, 1#18 + 1 FS PR #22 FRPVC
2#12, 1#18 + 1 FS PR #22 FRPVC
2#12, 1#18 + 1 FS PR #22 FRPVC
Revision Number: 1
© 2017 Belden, Inc
All Rights Reserved.
Revision Date: 02-09-2015
Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications described herein are subject to error or omission and to
change without notice, and the listing of such information and specifications does not ensure product availability.
Belden provides the information and specifications herein on an "AS IS" basis, with no representations or warranties, whether express, statutory or implied. In no event will Belden be liable for
any damages (including consequential, indirect, incidental, special, punitive, or exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether
in an action under contract, negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein.
All sales of Belden products are subject to Belden's standard terms and conditions of sale.
Belden believes this product to be in compliance with EU RoHS (Directive 2002/95/EC, 27-Jan-2003). Material manufactured prior to the compliance date may be in stock at Belden facilities
and in our Distributor’s inventory. The information provided in this Product Disclosure, and the identification of materials listed as reportable or restricted within the Product Disclosure, is
correct to the best of Belden’s knowledge, information, and belief at the date of its publication. The information provided in this Product Disclosure is designed only as a general guide for the
safe handling, storage, and any other operation of the product itself or the one that it becomes a part of. This Product Disclosure is not to be considered a warranty or quality specification.
Regulatory information is for guidance purposes only. Product users are responsible for determining the applicability of legislation and regulations based on their individual usage of the
product.
Belden declares this product to be in compliance with EU LVD (Low Voltage Directive 2014/35/EU).
Page 2 of 3
09-11-2017