Detailed Specifications & Technical Data
METRIC MEASUREMENT VERSION
5000UH Multi-Conductor - Commercial Audio Systems - 2 Conductors Cabled
For more Information
please call
1-800-Belden1
General Description:
Security & Commercial Audio Cable, Riser-CL3R-FPLR 2-12 AWG stranded tinned copper conductors with
polyolefin insulation, PVC jacket with ripcord
Usage (Overall)
Suitable Applications:
Intercom/PA Systems, Sound/Audio Systems, Fire Alarm (For color Red only)(Dual Rated)
Physical Characteristics (Overall)
Conductor
AWG:
# Conductors AWG Stranding Conductor Material
2
12
19x25
TC - Tinned Copper
2
Total Number of Conductors:
Insulation
Insulation Material:
Insulation Material Wall Thickness (mm)
PP - Polypropylene 0.279
Outer Shield
Outer Shield Material:
Outer Shield Material
Unshielded
Outer Jacket
Outer Jacket Material:
Outer Jacket Material
Nom. Wall Thickness (mm)
PVC - Polyvinyl Chloride 0.432
Outer Jacket Ripcord:
Yes
Overall Cable
Overall Cabling Color Code Chart:
Number Color
1
2
Black
White
6.604 mm
Overall Nominal Diameter:
Mechanical Characteristics (Overall)
Operating Temperature Range:
Bulk Cable Weight:
Max. Recommended Pulling Tension:
Min. Bend Radius/Minor Axis:
-20°C To +75°C
74.410 Kg/Km
676.126 N
69.850 mm
Applicable Specifications and Agency Compliance (Overall)
Applicable Standards & Environmental Programs
NEC/(UL) Specification:
NEC Articles:
EU Directive 2011/65/EU (ROHS II):
EU CE Mark:
EU Directive 2000/53/EC (ELV):
EU Directive 2002/95/EC (RoHS):
EU Directive 2002/96/EC (WEEE):
EU Directive 2003/11/EC (BFR):
CL3R, FPLR
725 or 760
Yes
Yes
Yes
Yes
Yes
Yes
Page 1 of 2
09-11-2017
Detailed Specifications & Technical Data
METRIC MEASUREMENT VERSION
5000UH Multi-Conductor - Commercial Audio Systems - 2 Conductors Cabled
CA Prop 65 (CJ for Wire & Cable):
MII Order #39 (China RoHS):
Yes
Yes
Flame Test
UL Flame Test:
CSA Flame Test:
UL1666 Vertical Riser
FT4
Suitability
Suitability - Indoor:
Yes
Plenum/Non-Plenum
Plenum (Y/N):
Plenum Number:
No
6000UH
Electrical Characteristics (Overall)
Nom. Inductance:
Inductance (µH/m)
0.49215
Nom. Capacitance Conductor to Conductor:
Capacitance (pF/m)
78.744
Nom. Conductor DC Resistance:
DCR @ 20°C (Ohm/km)
5.2496
Max. Operating Voltage - UL:
Voltage
300 V RMS
Max. Recommended Current:
Description
Current
10C Temperature Rise 12 Amps per conductor @ 25°C ambient
Put Ups and Colors:
Item #
5000UH 0081000
5000UH 008500
5000UH 0101000
Putup
1,000 FT
500 FT
1,000 FT
Ship Weight
54.000 LB
29.000 LB
54.000 LB
Color
GRAY
GRAY
BLACK
Notes
Item Desc
2 #12 PO FRPVC
2 #12 PO FRPVC
2 #12 PO FRPVC
Revision Number: 0
© 2017 Belden, Inc
All Rights Reserved.
Revision Date: 08-28-2015
Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications described herein are subject to error or omission and to
change without notice, and the listing of such information and specifications does not ensure product availability.
Belden provides the information and specifications herein on an "AS IS" basis, with no representations or warranties, whether express, statutory or implied. In no event will Belden be liable for
any damages (including consequential, indirect, incidental, special, punitive, or exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether
in an action under contract, negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein.
All sales of Belden products are subject to Belden's standard terms and conditions of sale.
Belden believes this product to be in compliance with EU RoHS (Directive 2002/95/EC, 27-Jan-2003). Material manufactured prior to the compliance date may be in stock at Belden facilities
and in our Distributor’s inventory. The information provided in this Product Disclosure, and the identification of materials listed as reportable or restricted within the Product Disclosure, is
correct to the best of Belden’s knowledge, information, and belief at the date of its publication. The information provided in this Product Disclosure is designed only as a general guide for the
safe handling, storage, and any other operation of the product itself or the one that it becomes a part of. This Product Disclosure is not to be considered a warranty or quality specification.
Regulatory information is for guidance purposes only. Product users are responsible for determining the applicability of legislation and regulations based on their individual usage of the
product.
Belden declares this product to be in compliance with EU LVD (Low Voltage Directive 2014/35/EU).
Page 2 of 2
09-11-2017