PolySwitch®
PTC Devices
Overcurrent Protection Device
PRODUCT: AGRF800S-1
DOCUMENT: SCD26154
REV LETTER: F
REV DATE: JULY 26, 2016
PAGE NO.: 1 OF 2
Specification Status: Released
Electrical Rating
Voltage:
16V
DC
MAX
Insulating Material:
Cured, Flame Retardant Epoxy Polymer
Lead Material:
20 AWG Tin Plated Copper
(0.8 mm [0.032] nom. diameter)
Part Marking:
Manufacturer’s Mark
G8
and Part Identification
Lot Identification
TABLE I. DIMENSIONS:
A
B
MIN
4.3
(0.17)
C
MAX
5.8
(0.23)
MIN
25.4
(1.00)
D
MAX
--
--
MIN
--
--
E
MAX
3.0
(0.12)
MIN
MAX
MIN
MAX
mm::
--
12.7
16.0
20.9
in*:
--
(0.50) (0.630) (0.820)
*Rounded off approximation
CURRENT RATINGS
TIME TO
TRIP
F
TYP
1.2
(0.05)
TABLE II. PERFORMANCE RATINGS:
INITIAL
RESISTANCE
R
1 MAX
1 HR. POST TRIP
RESISTANCE
STANDARD TRIP
OHMS
AT 25C
R
A MAX
TRIPPED-
STATE
POWER
DISSIPATION
WATTS AT
25°C
TYP
AMPS
AT 25°C
HOLD HOLD TRIP
AT
AT
R
1 MAX
R
A MAX
8.0
7.6
15.0
Reference Documents:
Precedence:
Effectivity:
CAUTION:
flame.
SECONDS
AT 25°C, 40 A
MAX
OHMS
AT 25°C
MIN
MAX
OHMS
AT 25C
5.5
0.0049
0.0113
0.0175
0.0181
3.2
PS400, PS300 (reference for R
1 MAX
)
This specification takes precedence over documents referenced herein.
Reference documents shall be the issue in effect on the date of invitation for bid.
Operation beyond the rated voltage or current may result in rupture, electrical arcing or
Materials Information
ROHS Compliant
ELV Compliant
Pb-Free
Halogen Free*
HF
* Halogen Free refers to: Br≤900ppm, Cl≤900ppm, Br+Cl≤1500ppm.
© 2016 Littelfuse,Inc.
Specifications are subject to change without notice.
Revised July 26, 2016
littelfuse.com
PolySwitch®
PTC Devices
Overcurrent Protection Device
PRODUCT: AGRF800S-1
DOCUMENT: SCD26154
REV LETTER: F
REV DATE: JULY 26, 2016
PAGE NO.: 2 OF 2
TABLE III. AUTOMOTIVE SPECIFIC STRESS TESTS AND TEST CONDITIONS:
ELECTRICAL STRESS TESTS
ESD Voltage Withstand
(see note 1)
Short Circuit Fault Current Durability
TEST CONDITIONS (see note 2)
25kV
25 cycles, 16V, 200A
Fault Current Durability
End-of-life Mode Verification
Jump Start Endurance
(see note 1)
Load Dump Endurance
(see note 1)
350 cycles, 16V/100A
1750 cycles, 16V/100A
3 cycles, 26V, 1 minute duration
10 cycles, 86.5V
Note 1: The PolySwitch devices are tested in series with a load resistance and the voltages specified in the test
conditions are shared between the PolySwitch device and the load resistance as specified in PS400.
Note 2: Please refer to Appendix A of PS400 for the detailed test procedures
© 2016 Littelfuse,Inc.
Specifications are subject to change without notice.
Revised July 26, 2016