ED Series
The Global Expert in
Solid State Relay
Technology
ED Series
ABOUT US
Crydom, a brand of Custom Sensors & Technologies (CST) and
global
expert in Solid State Relay Technology,
has a distinguished record of
providing high quality, world class Solid State Relay and Control Products
for a variety of heating, lighting and motion control applications. Crydom
products, coupled with
unparalleled technical support, timely delivery
and competitive pricing,
provide Crydom’s clients with the innovative
products and support necessary to succeed in today’s competitive and
fast paced global markets.
Crydom’s extensive selection of standard off-the-shelf products is
constantly being updated and expanded through its continuous
improvement and aggressive new product development programs.
Utilizing state of the art designs, materials and technology, Crydom offers
a wide range of AC and DC output SSRs in industry standard Panel Mount,
PCB Mount and DIN Rail packages, all
meeting global safety and
standards agency requirements
such as CE, RoHS, UL, IEC, etc.
Bolstered by four decades of Solid State Relay operations experience,
Crydom also specializes and encourages
adapted
and
fully
custom-designed SSR products
for nearly any application where unique
specifications and optimized performance are critical for success.
Crydom’s modern purpose-built
100,000 square foot manufacturing
facility
houses all aspects of its ISO certified operation including Design
and Development Engineering, Manufacturing Operations and Quality
Assurance, Customer Service, Finance, Marketing and General
Management, permitting close coordination of all aspects of Crydom’s
activities.
Applications Engineering and Sales support are both
performed in the field to provide Crydom’s Customers with the
unparalleled technical and commercial support.
Following rigid design guidelines and standards, Crydom products have
set the bench mark for SSR performance and reliability world wide. In
addition to
award winning designs,
Crydom has acquired an impressive
list of
patents
related to SSRs and Solid State Controls, while continuing
to develop new circuit and technology-related inventions as part of
extensive R&D programs.
To learn more about Crydom SSR technology and products, or how an
alliance with Crydom can contribute to the success of your project, visit
www.crydom.com
or contact your authorized Crydom Distributor or
Crydom Customer Service Representative today.
DIN RAIL OR PC MOUNTED PLUG IN
SOLID STATE RELAYS & SOCKETS
“LIFEPLUS ED SERIES” PLUG IN SOLID
STATE RELAYS
Crydom’s new
“LifePlus ED Series”
of AC and DC Output Plug-in Solid
State Relays are designed to replace industry standard 12 x 29 mm plug-in
Electromechanical Relays. Crydom’s proven Solid State Relay
Technology offers substantial performance advantages over traditional
EMR switching solutions in many applications including significantly
greater life expectancy (>100 million operations), contactless high speed
switching which eliminates contact bounce, arcing and resulting electrical
noise, precise low power logic compatible control inputs, acoustically
silent operation and high shock and vibration resistance.
Available in a SPST N.O. configuration, the
“LifePlus ED series”
offer
output ratings of either 3 or 5 Amps rms at 24 to 280 VAC, or 5 Amps DC
at 1 to 48 or 1 to 80 VDC, all at 40 °C ambient temperature. AC outputs
incorporate Crydom’s proven Back-to-Back SCR technology while DC
outputs utilize high efficiency FETs, both technologies resulting in the
lowest possible on-state power dissipation and high surge current ratings
which makes the
“Crydom LifePlus”
an excellent choice for applications
such as small Motors, Solenoids, Heaters and Lamps. Optically isolated
control inputs available include 3 to 15 VDC, 18 to 32 VDC, 48 to 72 VDC,
18 to 36 VAC and 90 to 140 VAC.
Cydom’s
“LifePlus ED Series”
are UL 508 recognized for both general
purpose and motor control applications and compliant to IEC 62314 LC-A
resistive and LC-B inductive application requirements. They are also CE
certified to the IEC Low Voltage Directive and compliant to the IEC EMC
directive.
“LIFEPLUS ED SERIES” DIN RAIL AND
PCB MOUNT ACCESSORY SOCKETS
The
“LifePlus ED Series”
includes accessory sockets accepting the
Crydom
ED Series
SSRs and industry standard 12 x 29 mm plug-in relay
packages. One version socket fits standard 35 mm DIN rail while a second
version is PCB mountable, allowing direct replacement of SPST N.O.
EMRs in both type installations. Equipped with screws for wire termination
and a positive latch for relay retention, the
“LifePlus ED Series”
sockets
provide an easy means to install and utilize Crydom
ED Series
Solid State
Relays.
Featuring all solid state construction,
“LifePlus ED Series”
SSRs and
Sockets provide an excellent improvement in performance over
traditional EMRs. For more information on
“Crydom LifePlus”
Series
SSRs, contact the nearest Crydom Distributor, Representative or Local
Crydom Sales Office, or visit our website at www.crydom.com.
www.crydom.com
ED Series
ED Series
AC Output Pluggable SSRs
12 x 29 mm industry standard plug-in package
3 & 5 Amps output power rating available
3 to 15 VDC, 18 to 32 VDC, 48 to 72 VDC, 18 to 36 VAC & 90 to 140 VAC control input
options available
Plug in replacement of EMRs
Convenient Quick Connect terminals for PCB or direct wiring
Fits standard DIN rail & PCB mountable sockets, also available as accessories
UL & IEC Resistive/Motor Ratings available
LED input status indicator
Zero Voltage for resistive loads and Random Turn-On for inductive loads versions available
Output Specifications
(A)
Operating Voltage Range (47-63 Hz) [Vrms]
Transient Overvoltage [Vpk]
Maximum Off-State Leakage Current @ Maximum Operating Voltage [mArms]
Minimum Off-State dv/dt @ Maximum Rated Voltage [V/µsec]
Maximum Load Current [Arms]
Minimum Load Current [Arms]
1 Cycle Surge Current (50/60 Hz) [Apk]
Maximum I²t for Fusing (50/60Hz) [A² sec]
Maximum On-State Voltage Drop @ Rated Current [Vpk]
Minimum Power Factor (with Maximum Load)
UL 508 Resistive Load @ 280 VAC [Arms]
UL 508 Motor Controller @ 240 VAC [HP]
IEC 62314 LC-A @ 280 VAC [FLA]
IEC 62314 LC-B @ 240 VAC [Kw]
3
¼
3
0.37
240 / 250
(B)
285 / 260
≤1.1
0.5
5
½
5
0.55
500
3
150 mA
600 / 625
(A)
1780 / 1620
ED24x3
24-280 VAC
600
0.1
ED24x5
500
5
Input Specifications
(A)
Control Voltage Range
Minimum Turn-On Voltage
Must Turn-Off Voltage
Maximum Reverse Voltage [VDC]
Minimum Input Current (for on-state)
Maximum Input Current
Nominal Input Impeadance [Ohm]
Maximum Turn-On Time [msec] (Zero Voltage)
Maximum Turn-Off Time [msec]
ED24Dx
3-15 VDC
3 VDC
1.9 VDC
3.8 mA @ 3 VDC
33.8 mA @ 15 VDC
500
ED24Cx
18-32 VDC
18 VDC
10.5 VDC
3.8 mA @ 18 VDC
6.9 mA @ 32 VDC
4.8 K
ED24Fx
48-72 VDC
48 VDC
24 VDC
6
3.8 mA @ 48 VDC
5.8 mA @ 72 VDC
12.5 K
1/2 Cycle
(C)
1/2 Cycle
(D)
ED24E5
18-36 VAC
18 VAC
10 VAC
3.8 mA @ 18 VAC
8.5 mA @ 36 VAC
4.5 K
ED24B5
90-140 VAC
90 VAC
48 VAC
3.2 mA @ 90 VAC
4.9 mA @ 140 VAC
28 K
General Specifications
(A)
Dielectric Strength, Input to Output to Base (50/60Hz) [Vrms]
Minimum Insulation Resistance @ 500 VDC
Maximum Capacitance, Input to Output [pF]
Ambient Operating Temperature Range [°C]
Ambient Storage Temperature Range [°C]
IP ratings
Housing Material
Terminal Finish
LED Status Indicator for Control Input
Weight (typical) [oz] (gr)
Humidity
Terminal type / size [in] (mm)
ED24x3
3750
10
9
10
-30 to 80
-40 to 125
ED24x5
IP00 / IP10 when mounted in PCBSED / DRSED socket or equivalent
PBT 30% GF, UL 94 V0
Sulfamate Nickel
On: Green
0.705 (20)
5 to 85% HR
Quick Connect / 0.187 x 0.02 (4.75 x 0.51)
1.06 (30)
General Notes
(A)
All parameters at 25ºC unless otherwise specified.
(B)
T
J
= 25°C, time: 20 msec. (50 Hz) / 16.6 msec. (60 Hz).
(C)
Turn-On time for Random-type AC Output (R suffix) is 0.1 msec for DC Control Models, and for AC Control Models
is 20 msec.
(D)
Turn-Off Time for AC output versions with AC control is 30 msec.
(E)
UL ratings are for relays only. To achieve maximum ratings, there must be a minimum spacing of 0.67 in (≥17 mm)
between the devices in free air.
(F)
100% Duty Cycle.
Derating Curves
(E,F)
6.0
ED24xxx
Load Current (Amps)
5.0
4.0
3.0
2.0
1.0
0
10
20
30
40
50
60
70
80
5 Amps
3 Amps
Ambient Temperature (ºC)
Complete specifications of these & other Crydom products available at:
www.crydom.com
ED Series
Part Number Nomenclature
Output Voltage
06:
1-48 VDC (5 Amps only)
10:
1-80 VDC (5 Amps only)
24:
24-280 VAC
Operational Current
3:
3 Amps (not available with B & E suffixes)
5:
5 Amps
Wiring Diagram
(H,J)
RELAY
(K,L)
Part no.: ED series
(Bottom view)
3
4
2
4
(11)
3
(14)
Load
Series
ED
24
C
5
R
Switching Mode
Blank:
Zero Voltage Turn-On
(AC Output only)
R:
Random Turn-On
(AC Output only)
Required for valid part number
For options only and not required for valid part number
Control Voltage
B:
90-140 VAC
C:
18-32 VDC
D:
3-15 VDC
(G)
E:
18-36 VAC
F:
48-72 VDC
1
1 (A1)
5
5 (A2)
DC/AC
Control Voltage
Mechanical Dimensions
Tolerances: ±0.02 in / 0.5 mm
All dimensions are in: inches [millimeters]
AC Output: 5 Amps
DC Output: B, E suffix
SOCKET
Part no.: PCBSED
Load
(Bottom view)
3
(14)
3
4
2
1
4
(11)
.99
[25.0]
1.10
[27.9]
.82
[20.8]
AC Output: 3 Amps
DC Output: C, D & F suffix
1.47
[37.4]
5
5 (A2)
1 (A1)
.02
[0.5]
.30
[7.6]
.24
[6.1]
.20
[5.1]
.19
[4.8]
.10
[2.5]
1
5
2
4
3
.21
[5.3]
SOCKET
(M,N)
Part no.: DRSED
4
(11)
(Top view)
4
2
.12
[3.0]
3
(14)
3
.39
[9.9]
1.14
[29.0]
.50
[12.7]
(G)
5-15 VDC range for ED06/10D5
(H)
DC inductive loads must be diode suppressed.
(J)
No grounding required.
(K)
For sockets intended for AC input control voltage, the AC line can be wired to either DRSED socket terminal 1 (A1-) or terminal 5 (A2+). Proper
polarity must be observed for DC input control voltage sockets being terminal 5 (A2+) positive with respect to terminal 1 (A1-).
(L)
For AC loads, the AC line can be wired to either DRSED socket terminal 4 (11) or terminal 3 (14). The AC load may also be wired on either the
line or neutral side of the SSR. For DC loads, the proper polarity must be observed for the power supply, load and DRSED socket with terminal
3 (14) being positive with respect to terminal 4 (11).
(M)
Minimum wire strip lenght 0.197 in (5 mm), maximum 0.256 in (6.5 mm) for wiring socket DRSED.
(N)
Input / Output terminals screw M3 Combo Drive for socket DRSED.
5 (A2)
Load
1 (A1)
ED Series Accessories
DRSED
DIN Rail Mountable Socket
Part no.: DRSED
Fingersafe IP10 DIN rail mountable socket to
mount ED series relays onto standard 35 mm
DIN rail. Rated at 250 V AC/DC, 12 Amps. The
DRSED includes M3 Combo screws.
PCBSED
PC Board Mountable Socket
Part no.: PCBSED
PC Board mountable socket for ED series
relays. Rated at 250 V AC/DC, 12 Amps.
Suggested Pin-out hole diameter: 1.0 mm
Questions?
Call or e-mail:
America
Tel.: +1 (877) 502 5500
e-mail: sales@crydom.com
EMEA
Tel.: +44 (0) 1202 606030
e-mail: sales-europe@crydom.com
Asia
Tel.: +86 (0) 21 2401 7766
e-mail: sales-cn@crydom.com
ED Series
ED Series
DC Output Pluggable SSRs
12 x 29 mm industry standard plug-in package
5 Amps output power rating
5 to 15 VDC, 18 to 32 VDC, 48 to 72 VDC, 18 to 36 VAC & 90 to 140 VAC control
input options available
Plug in replacement of EMRs
Convenient Quick Connect terminals for PCB or direct wiring
Fits standard DIN rail & PCB mountable sockets, also available as accessories
UL & IEC Resistive/Motor Ratings available
LED input status indicator
Output Specifications
(A)
Absolute maximum operating voltage [VDC]
Rated Voltage [VDC]
ED06x5
60
1-48
ED10x5
100
1-80
EDxxD5
Maximum Off-State Leakage Current @ Rated Voltage [µA]
Maximum Load Current [A]
Minimum Load Current [A]
Maximum Surge Current (10ms) [ADC]
Maximum On-State Voltage Drop @ 40ºC Rated Current [VDC]
Maximum On-State Resistance (RDS-ON) [Ohm]
Maximum PWM (Hz)
UL 508 Resistive Load @ Rated Voltage [A]
UL 508 Motor Controller@ Rated Voltage [FLA]
IEC 60947-4-1 DC-1@ Rated Voltage [ADC]
IEC 60947-4-1 DC-3@ Rated Voltage [FLA]
500
5
2
5
5
EDxxC5
EDxxF5
20
(P)
5
0.1
60
(Q)
≤ 0.3
0.034
(R)
EDxxE5
EDxxB5
500
5
2
5
5
500
5
2
5
5
N/A
5
1.5
5
5
N/A
5
1.5
5
5
Input Specifications
(A)
Control Voltage Range
Minimum Turn-On Voltage
Must Turn-Off Voltage
Maximum Reverse Voltage [VDC]
Minimum Input Current (for on-state)
Maximum Input Current
Nominal Input Impeadance [Ohm]
Maximum Turn-On Time [msec]
Maximum Turn-Off Time [msec]
EDxxD5
5-15 VDC
5 VDC
1.3 VDC
11 mA @ 5 VDC
42.8 mA @ 15 VDC
350
EDxxC5
18-32 VDC
18 VDC
2.0 VDC
10.7 mA @ 18 VDC
19.7 mA @ 32 VDC
1.6 K
EDxxF5
48-72 VDC
48 VDC
4.0 VDC
3
10.8 mA @ 48 VDC
16.3 mA @ 72 VDC
4.4 K
0.6
0.3
EDxxE5
18-36 VAC
18 VAC
4.0 VAC
12 mA @ 18 VAC
25.3 mA @ 36 VAC
1.5 K
EDxxB5
90-140 VAC
90 VAC
11 VAC
7.3 mA @ 90 VAC
10.9 mA @ 140 VAC
12.5 K
General Specifications
(A)
Dielectric Strength, Input/Output/Base (50/60Hz) [Vrms]
Minimum Insulation Resistance @ 500 VDC
Maximum Capacitance, Input/Output [pF]
Ambient Operating Temperature Range [°C]
Ambient Storage Temperature Range [°C]
Housing Material
Terminal Finish
IP ratings
LED Status Indicator for Control Input
Weight (typical) [oz] (gr)
Humidity
Terminal type / size [in] (mm)
EDxxD5
EDxxC5
EDxxF5
2500
10
9
10
-30 to 80
-40 to 125
PBT 30% GF, UL 94 V0
EDxxE5
EDxxB5
Sulfamate Nickel
IP00 / IP10 when mounted in PCBSED / DRSED socket or equivalent
On: Green
0.705 (20)
0.705 (20)
0.705 (20)
5 to 85% HR
Quick Connect / 0.187 x 0.020 (4.75 x 0.51)
1.06 (30)
1.06 (30)
General Notes
(A)
All parameters at 25ºC unless otherwise specified.
(P)
Output Voltage is Maximum Operating Voltage, Control Voltage = 0 V, T
J
= 25°C
(Q)
Output Voltage = 2.5 VDC
(R)
At maximum load current
(S)
UL ratings are for relays only. To achieve maximum ratings, there must be a minimum spacing of
0.63 in (≥16 mm) between the devices in free air
(F)
100% Duty Cycle
Derating Curves
(S,F)
ED06x5 & ED10x5
6.0
Load Current (Amps)
5.0
4.0
3.0
2.0
1.0
0
10
20
30
40
50
60
70
80
Ambient Temperature (ºC)
Complete specifications of these & other Crydom products available at: