The ABC225 Series of open-frame power supplies, with its wide
universal 90-264 VAC input range and high power density, is available
at 225 W of output power and a variety of single and multiple output
voltages.
The high efficiency and high power density of the ABC family ensures
minimal power loss in end-use equipment, thereby facilitating higher
reliability, easier thermal management and meets regulatory
approvals for environmentally-friendly end products.
These power supplies are ideal for telecom, datacom, industrial
equipment and other applications.
•
•
•
•
•
•
•
•
•
2 x 4 x 1 Inches Form Factor
225 W with Forced Air Cooling
Efficiencies up to 94%
-40 to 70 °C Operating Temperature
12 V Fan Output, Thermal Shut-Down Feature
3.37 Million Hours, Telcordia - SR332-Issue 3 MTBF
Standby Power <0.5 W
RoHS Compliant
CE Marked
•
•
•
•
Instrumentation
Lighting
Industrial Applications
Applied Computing
•
•
•
•
Renewable Energy
Test and Measurement
Robotics
Wireless Communication
2
ABC225 Series
MODEL NUMBER
1
ABC225-1T12L
ABC225-1012L
ABC225-1T15L
ABC225-1015L
ABC225-1T24L
ABC225-1024L
ABC225-1T30L
ABC225-1030L
ABC225-1T48L
ABC225-1048L
ABC225-1T58L
ABC225-1058L
DESCRIPTION
Screw Terminal
Molex Connector
Screw Terminal
Molex Connector
Screw Terminal
Molex Connector
Screw Terminal
Molex Connector
Screw Terminal
Molex Connector
Screw Terminal
Molex Connector
VOLTAGE
12 V
15 V
24 V
30 V
48 V
58 V
MAX. LOAD
(CONVECTION)
(112.5 W)
9.37 A
7.5 A
4.68 A
3.75 A
2.34 A
1.94 A
MAX. LOAD
(CONVECTION)
(120 W)
10.0 A
8.0 A
5.0 A
4.0 A
2.5 A
2.07 A
MAX. LOAD
(13 CFM)
18.75 A
15 A
9.37 A
7.5 A
4.68 A
3.88 A
MIN. LOAD
0.0 A
0.0 A
0.0 A
0.0 A
0.0 A
0.0 A
RIPPLE &
NOISE
2
1%
1%
1%
1%
1%
1%
COVER-225-XBC
3
metal cover kit accessory
Specifications are for nominal input voltage, 25°C unless otherwise stated.
PARAMETER
Input Voltage
Input Frequency
Input Current
No Load Power
Inrush Current
Leakage Current
Power Factor
Switching Frequency
115 VAC:
230 VAC:
Typical
115 VAC:
230 VAC:
264 VAC:
Typical (N.A. For Class II Option)
Touch current:
With Full Load
PFC:
PWM:
DESCRIPTION / CONDITION
Universal
(Derate from 100% at 100 VAC to 90% at 85 VAC)
SPECIFICATION
85-264 VAC / 390 VDC
47-63 Hz
2.2 A max.
1.1 A max.
< 0.5 W
25 A
45 A
75 A
300 µA
<100 µA
>0.95
70 to 130 kHz
50-80 kHz
1
For Class II (without input Earth pin) add suffix -2 (e.g.: ABC225-1012L-2). Ensure non-metallic mounting stud when installing a Class II
product.
2
Ripple is peak to peak with 20 MHz bandwidth and 10 µF (Tantalum capacitor) in parallel with a 0.1 µF capacitor at rated line voltage
and load ranges.
3
When used in Cover Kit, de-rate output power to 70 % under all operating conditions.
tech.support@psbel.com
ABC225 Series
PARAMETER
Output Power
4
Efficiency
Hold-up Time
Line Regulation
Load Regulation
Transient Response
Rise Time
Set Point Tolerance
5
Output Voltage Adjustment
6
Over Current Protection
Over Voltage Protection
Short Circuit Protection
Hiccup mode
25% step load change, at 0.1A/µs slew rate,
50% duty cycle, 50 Hz = 4%
Typical
DESCRIPTION / CONDITION
With 13 CFM:
Convection:
48 V:
24 V, 30 V:
12 V, 15 V:
225 W:
110 W:
SPECIFICATION
225 W
Up to 120 W
94%
93%
92%
10 ms
16 ms
+/-0.5%
+/-0.5%
Recovery time < 5 ms
55 ms
+/-1%
+/-3%
>110%
110 to 140%
3
Conducted Emissions
Radiated Emissions
Input Current Harmonics
Voltage Fluctuation and Flicker
ESD Immunity
Radiated Field Immunity
Electrical Fast Transient Immunity
Surge Immunity
Conducted Immunity
Magnetic Field Immunity
Voltage Dips, Interruptions
EN55032-B, CISPR22-B, FCC PART15-B
EN 55032 A;
with external core (King core K5B RC 25x12x15-M in input cable)
EN 61000-3-2
EN 61000-3-3
EN 61000-4-2
EN 61000-4-3
EN 61000-4-4
EN 61000-4-5
EN 61000-4-6
EN 61000-4-8
EN 61000-4-11
Pass
Pass
Level B
Class D
Pass
Level 3, Criterion A
Level 3, Criterion A
Level 3, Criterion A
Level 3, Criterion A
Level 3, Criterion A
Level 3, Criterion A
Criterion A & B
PARAMETER
Isolation Voltage
Safety Standard(s)
Agency Approvals
CE mark
DESCRIPTION / CONDITION
SPECIFICATION
Input to Output: (For ITE application)
Input to GND: (Not Applicable For Class II Option)
Approved to the latest edition of the following standards:
CSA/UL60950-1, EN60950-1 and IEC60950-1; Class1 SELV.
Nemko, UL, C-UL
Complies with LVD Directive
3000 VAC
1500 VAC
4
5
Combined output power of main output, fan supply shall not exceed max. Power rating.
Fan supply output voltage tolerance including set point accuracy, line & load regulation is +/-10% and Ripple & noise is less than 10%.
6
Adjustment potentiometer is located on the SMT side of the PCB.
Asia-Pacific
+86 755 298 85888
Europe, Middle East
+353 61 225 977
North America
+1 408 785 5200
BCD.00554_AG
© 2017 Bel Power Solutions & Protection
4
ABC225 Series
DESCRIPTION / CONDITION
Start-up is guaranteed, with spec deviation, see Fig. 1
With 13 CFM forced air cooling
With natural convection cooling at 100 to 264 VAC
Noncondensing
Operating:
Nonoperating:
MTBF according to Telcordia -SR332-issue 3:
SPECIFICATION
-40 to +70°C
-40 to 0°C
-40 to +85°C
225 W
Up to 120 W
5% to 95%
16,000 ft.
40,000 ft.
3.37 million hours
PARAMETER
Operating Temperature
7
Storage Temperature
Cooling
Relative Humidity
Altitude
Reliability
Convection load: 120 W up to 40 °C
De-rate between 40-50 °C @ 0.625% per °C
De-rate above 50 °C @ 2.33% per °C
Forced air cooled load: 225 W up to 50°C
De-rate above 50 °C @ 2.5% per °C
Figure 1. Derating Curve
Figure 2. Efficiency Graph at 115 VAC
Figure 3. Efficiency Graph at 230 VAC
7
Output ripple can be more than 10% of the output voltage.
tech.support@psbel.com
ABC225 Series
5
CONNECTOR
AC Input Connector
PIN
J1
DESCRIPTION/CONDITION
Pin 1
Pin 2
Pin 3
Pin 1,2,3
Pin 4,5,6
Pin 1
Pin 2
AC Line
Not Fitted
AC Neutral
V1 +VE
V1 - VE
FAN +VE
FAN - VE
Screw Terminal (Option 1)
Molex Connector (Option 2)
MANUFACTURER / PN
Molex: 26-60-4030
Mating: 09-50-3031; Pins: 08-50-0106
Molex: 39357 Series or equivalent
Molex: 26-60-4060
Mating: 09-50-3061; Pins: 08-50-0106
AMP :640456-2
Mating: 640440-2
DC Output Connector
Aux (Fan) Output
J2
J3
PARAMETER
Weight
Dimensions
Cooling
8
DESCRIPTION/CONDITION
200 g approx.
50.8 x 101.6 x 25.4 mm (2 x 4 x 1 inch)
225 W with 13 CFM forced air cooling (refer Mechanical Drawing)
Up to 120 W with natural convection cooling (refer Derating Curve)
Figure 4. Mechanical Drawing
–
Screw Terminal (Option 1)
8
225 W with 13CFM forced air cooling and 120 W with natural convection cooling at 100 to 264 VAC.
Asia-Pacific
+86 755 298 85888
Europe, Middle East
+353 61 225 977
North America
+1 408 785 5200
BCD.00554_AG
© 2017 Bel Power Solutions & Protection