Measuring transducer power supply and input signal conditioner, HART-transparent. Transfers supplied or active
4 - 20 mA electrically isolated signals from the field to two loads. 4-way electrical isolation, PLd
The figure shows a version with a
screw connection
Product Features
Key commercial data
Packing unit
Custom tariff number
Country of origin
1 pc
85437090
Germany
Technical data
Note
Utilization restriction
EMC: class A product, see manufacturer's declaration in the download
area
Dimensions
Width
Height
Depth
12.5 mm
99 mm
114.5 mm
Ambient conditions
Ambient temperature (operation)
Ambient temperature (storage/transport)
Maximum altitude
Permissible humidity (operation)
Noise immunity
-20 °C ... 60 °C (Any mounting position)
-40 °C ... 80 °C
≤ 2000 m
10 % ... 95 % (non-condensing)
EN 61000-6-2 When being exposed to interference, there may be minimal
deviations.
05/18/2015 Page 1 / 5
https://www.phoenixcontact.com/us/products/2904962
Repeater power supply - MACX PL-RPSSI-2I-SP - 2904962
Technical data
Ambient conditions
Degree of protection
IP20
Input data
Signal input
Current input signal
Transmitter supply voltage
Signal input
Current input signal
Voltage drop
Repeater power supply operation
4 mA ... 20 mA
> 21.5 V (20 mA)
> 21 V (23 mA)
Signal conditioner operation
4 mA ... 20 mA
< 3.9 V
Output data
Signal output
Current output signal
Load/output load current output
Output ripple
Output behavior in the event of an error
Signal output
Current output signal
Load/output load current output
Output ripple
Output behavior in the event of an error
Repeater power supply operation
4 mA ... 20 mA (active)
< 450 Ω (20 mA)
< 380 Ω (23 mA)
< 20 mV
rms
0 mA (Cable break in the input)
≥ 23 mA (Cable short-circuit in the input)
Signal conditioner operation
4 mA ... 20 mA (active)
< 450 Ω (20 mA)
< 380 Ω (23 mA)
< 20 mV
rms
0 mA (Cable break in the input)
≥ 23 mA (Cable short-circuit in the input)
Power supply
Designation
Supply voltage range
Max. current consumption
Power consumption
Repeater power supply operation
19.2 V DC ... 30 V DC (24 V DC (-20% ... +25%))
< 75 mA (24 V DC)
< 1.45 W (24 V DC/ 20 mA)
Connection data
Conductor cross section solid min.
Conductor cross section solid max.
Conductor cross section flexible min.
Conductor cross section flexible max.
Conductor cross section AWG min.
0.2 mm²
1.5 mm²
0.2 mm²
1.5 mm²
24
05/18/2015 Page 2 / 5
https://www.phoenixcontact.com/us/products/2904962
Repeater power supply - MACX PL-RPSSI-2I-SP - 2904962
Technical data
Connection data
Conductor cross section AWG max.
Stripping length
Connection method
16
8 mm
Push-in connection
General
Maximum transmission error
Transmission error, typical
Maximum temperature coefficient
Step response (10-90%)
Status display
Inflammability class according to UL 94
Electromagnetic compatibility
Housing material
Color
Designation
Electrical isolation
< 0.1 % (of final value)
< 0.05 % (of final value)
< 0.01 %/K
< 1.3 ms (for 4 mA ... 20 mA step)
Green LED (PWR supply voltage)
V0
Conformance with EMC Directive 2004/108/EC
PA 66-FR
yellow
Input/output/power supply
300 V
rms
(Rated insulation voltage (surge voltage category II; pollution
degree 2, safe isolation as per EN 61010-1))
2.5 kV (50 Hz, 1 min., test voltage)
Designation
Electrical isolation
Conformance
ATEX
Output 1/output 2
1.5 kV AC (50 Hz, 1 min., test voltage)
CE-compliant, additionally EN 61326
II 3 G Ex nA IIC T4 Gc X
Data communication (bypass)
HART function
Protocols supported
Yes
HART
EMC data
Designation
Standards/regulations
Typical deviation from the measuring range final value
Designation
Standards/regulations
Typical deviation from the measuring range final value
Designation
Standards/regulations
Typical deviation from the measuring range final value
Electromagnetic RF field
EN 61000-4-3
3%
Fast transients (burst)
EN 61000-4-4
3%
Conducted interferences
EN 61000-4-6
3%
05/18/2015 Page 3 / 5
https://www.phoenixcontact.com/us/products/2904962
Repeater power supply - MACX PL-RPSSI-2I-SP - 2904962
Classifications
eCl@ss
eCl@ss 4.0
eCl@ss 4.1
eCl@ss 5.0
eCl@ss 5.1
eCl@ss 6.0
eCl@ss 7.0
eCl@ss 8.0
27210120
27210120
27210120
27210120
27210120
27210120
27210120
ETIM
ETIM 2.0
ETIM 3.0
ETIM 4.0
ETIM 5.0
EC001485
EC001485
EC001485
EC002653
UNSPSC
UNSPSC 6.01
UNSPSC 7.0901
UNSPSC 11
UNSPSC 12.01
UNSPSC 13.2
30211506
39121008
39121008
39121008
39121008
Approvals
Approvals
Approvals
UL Listed / cUL Listed / GL / cULus Listed
Ex Approvals
Approvals submitted
Approval details
05/18/2015 Page 4 / 5
https://www.phoenixcontact.com/us/products/2904962
Repeater power supply - MACX PL-RPSSI-2I-SP - 2904962
Approvals
UL Listed
cUL Listed
GL
cULus Listed
Drawings
Block diagram
Sensor / Field
IN
OUT
PLC / DCS
4.2 - 4.2
3.2 - 3.2
-
+
passive
OUT 1
4.1
HHT
+
4.1
3.1
+
3.1
HHT
or
2.2
2.2
2.1
-
+
HHT
OUT 2
5.2 - 5.2
5.1
HHT
2.1
+
5.1
GND
+24V
Power
GND +24V
1.2
1.1
passive
Zone 2
Div. 2
Phoenix Contact 2015 © - all rights reserved