CPD 3000
Outdoor Lighting Controller
Reduce Energy Use up to 30%
CPD 3000 Key Features
• Provides ISO/IEC 14908-1 and -3 compliant, power line-based, two-way
communications between lamps and segment controllers.
• Provides vital data to the segment controller that reduces energy use
and operating costs.
• Optimizes communications with integrated power line meshing
• Enables remote command and control at every lamp.
• Reduces installation and deployment costs.
• Future proofs lighting systems at lower cost with remote
firmware update abilities.
• Eliminates failure-prone photocells at the luminaires by leveraging the
segment controller’s time and astronomical-based scheduling
• An integral component of Echelon’s smart street lighting solution, the CPD
3000 Outdoor Lighting Controller (OLC) uses ISO compliant, power line
communications technology to manage outdoor lighting luminaires in street,
parking, industrial complex, and other outdoor area lighting systems. When
used with the Echelon SmartServer Segment Controller, cities can implement
smart outdoor lighting systems that reduce energy use by 30% or more
beyond gains from efficient lamp technologies and cut operating costs by
20%. Together, the segment controller and CPD 3000 OLC increase safety and
beautify cities through remote monitoring and control of individual lights and
segments of lights.
Proven, high reliability, two-way
communications with each lighting
fixture without new wiring.
Over 500 cities have lighting systems based
on Echelon’s smart street lighting solution and
the technology used in the OLC. The OLC uses
existing power lines to communicate with the
outdoor lighting network Segment Controller (an
Echelon SmartServer 2.0 Controller). The Segment
Figure 1. CPD 3000 System Architecture
www.echelon.com
®
Controller consolidates data from the
CPD 3000 devices within the outdoor
lighting network to allow operators to
remotely monitor and control the entire
network. One Segment Controller can
manage and control up to 200 devices
— OLC-controlled luminaires along with
optional Echelon CRD 3000 PL/RF Bridge
modules, as shown in
Figure 1.
The system
architecture of Segment Controllers, PL/
RF bridges, and OLCs allows single lighting
networks to scale to tens of thousands
of individually controlled and monitored
lights.
The CPD 3000 provides vital data for each
lamp and serves as a monitoring and fault
detection device. Data includes:
Environmental
Operating temperature range: -40 °C
to +70 °C
Fully potted electronics
Moisture & Humidity: 5% to 95% RH,
non-condensing
Storage Temperature: -40 °C to +85 °C
Vibration: 5 Hz - 7.5 Hz @ 0.5” D.A., 5.5
Hz-200 Hz @ 1.5G
Shock: 30 g @ 11 ms; 100 g @ 3 ms
(half sine)
IP Rating: IP66 for outdoor applications
EMC
FCC Part 15 Class B
Agency Listings: This product meets CB
Certification.
UL 60950, UL 60950-1
CE — Europe, EN 60950-1, EN 55022,
EN 55024
C -Tick — Australia, AS/NZS
CISPR 22 Class 22
FCC — US, FCC Part 15 Subpart B
VCCI — Japan, CISPR 22 Class B
cUL — Canada, cUL C22.2
No. 60950-00
PSE — Japan
RoHs Compliant
The CPD 3000 module is compliant
with the European Directive 2002/95/
EC on the restriction of the use of
certain hazardous substances (RoHS) in
electrical and electronic equipment.
Physical,Weight: 800 grams
Size: Length 167 mm, Width 74 mm,
Height 37.5 mm
Warranty
5-year limited warranty*
• Lamp Run Hours
• Voltage
• Current
• Lamp Status
• Present Power Consumption
• Diagnostic Alarms
• Power Factor
Enables the use of multiple
lighting technologies and
power supplies to suit
end-user needs and
technology evolution.
The CPD 3000 can be embedded in a
lighting fixture in minutes, regardless of
lighting technology, to control various
types of lighting power supplies including:
Specifications
Input Voltage
Model #: 76600R – UL Certification
100 VAC to 277 VAC (2 Wire + Earth)
Model #: 76610R – CB Certification
100 VAC to 250 VAC (2 Wire + Earth)
Frequency: 47 to 63 Hz
Current: Max 5 Amp
Power Line Communications
Dual frequency 115 kbps and 132 kbps.
Two-way communications on the
LonWorks PL channel based on the ISO/
IEC 14908-3 standard.
Power Line Repeating: The CPD 3000
can repeat messages within the outdoor
lighting network, as requested by the
Segment Controller. If PL communications
fail between the Segment Controller and a
particular CPD 3000 module, the Segment
Controller can dynamically specify another
CPD 3000 to act as a repeater to maintain
overall network communications. If the
network includes CRD 3000 PL/RF Bridge
modules, the Segment Controller can route
messages throughout the network using
either Power Line or Radio Frequency
communications, as needed.
Metering capability with 2% accuracy
Dimming capability using PWM and 0-10V
Power
Filtered auxiliary power output for lighting
Maximum 500 Watt luminaires
Switched internal relay for turning
lights on/off
Greater than 48 dB attenuation for lighting
noise sources (built-in filter)
• Induction Lighting — Electronic
Ballast/Generator
• High-Pressure Sodium (HPS)
Lighting — Ballast
• Light Emitting Diode (LED)
Lighting — Driver
The CPD 3000 can use control signals
such as 0-10 V lighting control (for
example, the ESTA E1.3, Entertainment
Technology — Lighting Control System
- 0 to 10V Analog Control Protocol), and
pulse-width modulation (PWM), compliant
with IEC60929 standard..
Embeds intelligence into
street lighting systems
to reduce operating costs
and energy use, improve
reliability, and increase
comfort.
*Subject to terms and conditions found at http://echelon.com/lp/warranty_five_year
www.echelon.com
®
Installation
The CPD 3000 Outdoor Lighting Controller
can be installed within the lighting fixture,
in the access hole of the lighting fixture
pole, in the gear tray, or in a separate box.
Figure 2
shows a typical installation within
the lighting fixture.
Wiring Specification and Diagram (US Models)
Three 16 AWG wires for AC mains input
Black
White
Green
Line In
Neutral In
Ground
Three AWG 22 wires for control signal output
(IEC60929)
Blue
Black
Violet
10V signal for PWM control
Ground
Signal for 0-10V control
Wiring Specification and Diagram (European Models)
Double insulated 3 x 18 AWG for AC mains input
Brown
Line In
Neutral In
Ground
Blue
Green/Yellow
*
*CPD 3000 may require addition of an impedance element in series with the
control lines to ensure compliance with conductive emissions regulations in some
regions. This impedance element is not required in all cases and is dependent on
the driver or ballast used.
Double insulated 3 x 18 AWG for control signal output
(IEC60929)
Blue
Black
White
10V signal for PWM control
+ Signal for 0-10V control
- Signal for 0-10V control
Double insulated 3 x 18 AWG for filtered power output
Figure 2. CPD 3000 Installed in
the Light Fixture
Brown
Blue
Green/Yellow
Installation for the CPD 3000 OLC is
simple:
1. Install the CPD 3000 OLC.
2. Connect AC mains power to the CPD
3000 OLC.
Important:
Disconnect line voltage before
installing or replacing the CPD 3000 OLC.
3. Connect the filtered power output of the
CPD 3000 OLC to the luminaire
power supply (electronic ballast/
generator, ballast, or driver).
4. Connect the CPD 3000 control signal
wires to the luminaire control input.
Line Out
Neutral Out
Ground
CPD 3000 Mechanical Dimensions
Model and Ordering Information
CPD 3000 — Outdoor Lighting Controller
76600 R : US Models
76610 R : European Models
Note:
1. This product is not suitable for installation above 15,000 ft altitude.
2. This product must be installed in the light fixture, inside a street light pole, or in a street light cabinet.
3. This product is not intended to be installed in an open outdoor environment.
For more information about this product, contact us at +1 408 938 5200 or visit www.echelon.com.
Figure 3. CPD 3000 Housing Profile (dimensions in millimeters)
© 2016 Echelon, and the Echelon logo are trademarks of Echelon Corporation registered in the United States and other countries.
Other trademarks belong to their respective holders. Content subject to change without notice.
P/N 003-0517-01F rev 12/16
www.echelon.com