Data sheet
PROeco
PRO ECO 480W 24V 20A
Weidmüller Interface GmbH & Co. KG
Klingenbergstraße 16
D-32758 Detmold
Germany
Fon: +49 5231 14-0
Fax: +49 5231 14-292083
www.weidmueller.com
You are looking for a reliable power supply with basic
functions.
With PROeco we can offer you low-cost switch-mode
power supply units with
high efficiency and system capability. Let’s connect.
In the series production of machines, in particular, switch-
mode power supply units with
above-average performance values can deliver genuine
competitive advantages.
The low-cost PROeco series offers all the basic functions
and delivers impressively
high performance and flexibility.
Our PROeco switch-mode power supply units feature a
compact design, high
efficiency and are extremely easy to maintain. Thanks to
temperature protection,
short-circuit and overload resistance they can be
universally used in all
applications.
Wide-ranging safety functions and compatibility with our
diode and capacitance modules, together with UPS
components for setting up a
redundant power supply, characterise solutions with
PROeco.
General ordering data
Type
Order No.
Version
GTIN (EAN)
Qty.
PRO ECO 480W 24V 20A
1469510000
Power supply, switch-mode power supply unit, 24
V
4050118275483
1 pc(s).
Creation date August 11, 2015 5:29:12 PM CEST
Catalogue status 24.07.2015 / We reserve the right to make technical changes.
1
Data sheet
PROeco
PRO ECO 480W 24V 20A
Weidmüller Interface GmbH & Co. KG
Klingenbergstraße 16
D-32758 Detmold
Germany
Fon: +49 5231 14-0
Fax: +49 5231 14-292083
www.weidmueller.com
Technical data
100 mm
120 mm
1,557 g
Height
Weight
Dimensions and weights
Width
Depth
Net weight
125 mm
1,557 g
Temperatures
Operating temperature
-25 °C...70 °C
Storage temperature
-40 °C...85 °C
Input
AC current consumption
Connection system [Input]
DC input voltage range
Input frequency
Inrush current
Recommended back-up fuse
2,37 A @ 230 V AC / 5,2
A @ 110 V AC
Screw connection
80…370 V DC (Derating @
120 V DC)
47...63 Hz
max. 5 A
6 A / DI, safety fuse
16 A, Char. B, circuit
breaker
6...8 A, Char. C, circuit
breaker
AC input voltage range
DC current consumption
Frequency range AC
Input fuse (internal)
Rated input voltage
85…264 V AC (Derating @
100 V AC)
1,55 A @ 370 V DC / 4,65
A @ 120 V DC
47...63 Hz
Yes
100...240 V AC (wide-
range input)
output
Capacitive load
Continuous output current @ U
Rated
Output voltage
Overload protection
Protection against inverse voltage
Rated (nominal) output current @ U
Nom
Residual ripple, breaking spikes
unrestricted
20 A @ 55 °C, 15 A @ 70
°C
24 V
Yes
Yes
20 A @ 55 °C
< 50 mV
SS
@ 24 V DC, I
N
Connection system [Output]
Output power
Output voltage
Parallel connection option
Ramp-up time
Rated output voltage
Screw connection
480 W
22...28 V (adjustable via
potentiometer)
yes, max. 3
≤ 100 ms
24 V DC ± 1 %
General data
AC failure bridging time @ I
Nom
Earth leakage current, max.
Indication
Max. perm. air humidity (operational)
Operating temperature
Power loss, idling
Protection against over-heating
Short-circuit protection
> 20 ms @ 230 V AC / >
20 ms @ 115 V AC
1 mA
LED green (U
output
>
21.6 V DC), LED yellow
(I
output
> 90% I
Rated
typ. ), LED red (overload,
overtemperature, short-
circuit, U
output
< 20.4 V
DC)
5 %…95 % RH
-25 °C...70 °C
5W
Yes
Yes
Degree of efficiency
Housing version
MTBF
91%
Metal, corrosion resistant
Mounting position, installation notice
Power factor (approx.)
Power loss, nominal load
Protection degree
Weight
> 500,000 h acc. to IEC
1709 (SN29500
horizontally, on terminal
rail TS 35
> 0.98 @ 230 V AC / >
0.98 @ 115 V AC
43 W
IP 20
1,557 g
Creation date August 11, 2015 5:29:12 PM CEST
Catalogue status 24.07.2015 / We reserve the right to make technical changes.
2
Data sheet
PROeco
PRO ECO 480W 24V 20A
Weidmüller Interface GmbH & Co. KG
Klingenbergstraße 16
D-32758 Detmold
Germany
Fon: +49 5231 14-0
Fax: +49 5231 14-292083
www.weidmueller.com
Technical data
in accordance with EN
61000-3-2
EMC / shock / vibration
Limiting of mains voltage harmonic
currents
Vibration resistance IEC 60068-2-6
Noise emission acc. to EN55022
Interference immunity test acc. to
Shock resistance IEC 60068-2-27
1 g according to EN50178
15 g In all directions
Class B
EN 61000-4-2 (ESD),
EN 61000-4-3 (RS), EN
61000-4-4 (burst), EN
61000-4-5 (surge), EN
61000-4-6 (conducted),
EN61000-4-8 (Fields),
EN61000-4-11 (Dips)
Insulation coordination
Class of protection
Insulation voltage output / earth
Pollution severity
I, with PE connection
0.5 kV
2
Insulation voltage input / earth
Insulation voltage, input/output
2 kV
3 kV
Electrical safety (applied standards)
Electrical machine equipment
Acc. to EN60204
Acc. to VDE0106-101
SELV acc. to EN60950,
PELV acc. to EN60204
For use with electronic equipment
Protective separation / protection
against electrical shock
Safety transformers for switch-mode
power supplies
Acc. to EN50178 /
VDE0160
VDE0100-410 / acc. to
DIN57100-410
IEC61558-2-16
Protection against dangerous shock
currents
Safety extra-low voltage
Connection data (input)
Conductor cross-section, AWG/kcmil ,
max.
Conductor cross-section, flexible , min.
Conductor cross-section, rigid , min.
Number of terminals [Input]
Tightening torque, min.
12
0.5 mm²
0.5 mm²
3 for L/N/PE
0.5 Nm
Conductor cross-section, AWG/kcmil ,
min.
Conductor cross-section, rigid , max.
Connection system [Input]
Tightening torque, max.
Wire connection cross section, flexible
(input), max.
26
6 mm²
Screw connection
0.6 Nm
2.5 mm²
Connection data (output)
Conductor cross-section, AWG/kcmil ,
max.
Conductor cross-section, flexible , max.
Conductor cross-section, rigid , max.
Connection system [Output]
Tightening torque, max.
10
2.5 mm²
6 mm²
Screw connection
0.6 Nm
Conductor cross-section, AWG/kcmil ,
min.
Conductor cross-section, flexible , min.
Conductor cross-section, rigid , min.
Number of terminals [Output]
Tightening torque, min.
26
0.5 mm²
0.5 mm²
7 (++,---,13,14)
0.5 Nm
Signalling
Contact load (NO contact)
Relay on/off
max. 30 V DC / 1 A
Output voltage >21.6 V
DC/ <20.4 V DC, Overload
Floating contact
Yes
Creation date August 11, 2015 5:29:12 PM CEST
Catalogue status 24.07.2015 / We reserve the right to make technical changes.
3
Data sheet
PROeco
PRO ECO 480W 24V 20A
Weidmüller Interface GmbH & Co. KG
Klingenbergstraße 16
D-32758 Detmold
Germany
Fon: +49 5231 14-0
Fax: +49 5231 14-292083
www.weidmueller.com
Technical data
Certificate no. (cULus)
Approvals
Institute (cULus)
E258476
Classifications
ETIM 5.0
eClass 6.2
eClass 8.1
EC002541
27-04-90-04
27-04-90-04
ETIM 6.0
eClass 7.1
eClass 9.0
EC002541
27-04-90-04
27-04-07-03
Product information
Descriptive text ordering data
The internal varistor found in a switch-mode power supply does not replace the need for surge protection within
a system.
Approvals
Approvals
ROHS
Conform
Downloads
Package insert
Declaration of Conformity
3-D model
Operating instructions
K562_01_14.pdf
Creation date August 11, 2015 5:29:12 PM CEST
Catalogue status 24.07.2015 / We reserve the right to make technical changes.
4
Data sheet
PROeco
PRO ECO 480W 24V 20A
Weidmüller Interface GmbH & Co. KG
Klingenbergstraße 16
D-32758 Detmold
Germany
Fon: +49 5231 14-0
Fax: +49 5231 14-292083
www.weidmueller.com
Drawings
Derating curve
Electric symbol
Creation date August 11, 2015 5:29:12 PM CEST
Catalogue status 24.07.2015 / We reserve the right to make technical changes.