Technical Data Sheet for
NL1507
Single-Stage Thermoelectric Module
NOMINAL PERFORMANCE IN NITROGEN
Hot Side Temperature (°C)
Δ Tmax (°C):
Qmax (watts):
Imax (amps):
Vmax (vdc):
AC Resistance (ohms):
27
64
5.4
1.8
4.7
2.30
50
72
6.2
1.8
5.4
--
PRODUCT FEATURES
•
•
•
•
RoHS EU Compliant
Pretinned metallized ceramic surface(s) with 96°C
or 117°C
solder.
Thermistor mounted on edge of cold side ceramic.
(Calibration available.)
Elevated temperature burn-in
with test data provided.
ORDERING OPTIONS
Model Number
NL1507-03AC
NL1507-04AC
Description
4mm Thru Hole
4mm Thru Hole, Inspected for
Alignment
OPERATION CAUTIONS
For maximum reliability, storage and operation below
85°C in a non-condensing
environment is recommended.
To minimize thermal stress, use linear/proportional
temperature control or a similar method rather than an
ON/OFF method.
INSTALLATION
[Use this statement for TEM <19mm length:]
Recommended mounting methods: Bonding with thermal
epoxy or soldering with metallized ceramics. For additional
information, please refer to our TEM Installation Guide.
II-VI
Marlow
–
Dallas, TX USA
214-340-4900
877-627-5691
marlow.sales@ii-vi.com
MI Form 005-0808 Rev. B
Marlow Industries Europe
GmbH -
Germany
+49 (0) 6150 5439
- 403
info@marlow-europe.eu
II-VI Japan Inc.
81 43 297 2693 (tel)
center@ii-vi.co.jp
www.ii-vi.co.jp
II-VI Singapore Pte., Ltd.
(65) 6481 8215 (tel)
info@ii-vi.com.sg
Marlow Industries China, II-VI
Technologies Beijing
86-10-643
98226
info@iivibj.com
www.marlow.com
DOC # 102-0328 REV M - PAGE 1 OF 2
TYPICAL PERFORMANCE CURVES
ENVIRONMENT: ONE ATMOSPHERE DRY NITROGEN
Hot Side Temperature 27°C
80.0
60.0
T (C)
HEAT
LOAD
(WATTS)
0.00
0.50
1.00
1.50
2.00
2.50
3.00
3.50
4.00
4.50
5.00
Hot Side Temperature 50°C
80.0
60.0
T (C)
HEAT
LOAD
(WATTS)
0.00
0.50
1.00
1.50
2.00
2.50
3.00
3.50
4.00
4.50
5.00
5.50
40.0
20.0
0.0
40.0
20.0
0.0
VOLTAGE (VDC)
4.0
3.0
2.0
1.0
0.0
0.0
0.4
0.8
1.2
1.6
CURRENT (AMPS)
2.0
Q=0
T=0
VOLTAGE (VDC)
5.0
5.0
4.0
3.0
2.0
1.0
0.0
0.0
0.4
0.8
1.2
1.6
CURRENT (AMPS)
2.0
Q=0
T=0
For performance information in a vacuum or with hot side temperatures other than 27°C or 50°C, contact one of our Applications Engineers at 877-627-5691.
MECHANICAL CHARACTERISTICS
All units are in inches, [ ] are in millimeters unless otherwise stated.
For customer support or general questions please contact a local office or visit our website at
www.marlow.com.
Marlow reserves the right to make product changes without notice.
MI Form 005-0808 Rev. B
www.marlow.com
DOC # 102-0328 REV M - PAGE 2 OF 2