https://www.phoenixcontact.com/us/products/1690273
Housing - HC-B 16-TMS-100/O1STM40G-EUA - 1690273
Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's
documentation. Our General Terms of Use for Downloads are valid
(http://download.phoenixcontact.com)
HEAVYCON ADVANCE for increased environmental requirements, sleeve housing B16, with screw locking,
height 100 mm, with 1x M40 thread, straight cable outlet
Key commercial data
Packing unit
Weight per Piece (excluding packing)
Custom tariff number
Country of origin
1 pc
377.31 GRM
85389099
Germany
Technical data
Dimensions
Height
Width
Length
Length of the assembly cutout
Width of the assembly cutout
100 mm
57 mm
126 mm
86 mm
35 mm
Ambient conditions
Degree of protection of housing (IP)
IP66
IP68 (0.2 bar 24 h)
IP69K
Degree of protection of housing (NEMA)
4 (UL50e / NEMA 250)
4X (UL50e / NEMA 250)
6P (UL50e / NEMA 250)
12 (UL50e / NEMA 250)
2/4/14 Page 1 / 5
https://www.phoenixcontact.com/us/products/1690273
Housing - HC-B 16-TMS-100/O1STM40G-EUA - 1690273
Technical data
Ambient conditions
Ambient temperature (operation)
-40 °C ... 125 °C
General
Note
Design
Housing type
Locking type
Torque
Fixing screws
No. of cable exits
Cable exit
Screw connection
Type of the screw connection
Housing material
Housing surface material
Seal material
Material lock
Assembly instructions
Connection
For contact inserts HC-B16, BB32, D40, DD72, HS6, HV6, M, K
B16
Sleeve housings
Screw locking
3 Nm (Locking screw)
M6
1
Straight
None
1x M40
Die-cast aluminum, salt water resistant
Powder-coated, black
Viton
High-grade steel
In order to guarantee that the ground conductor contact functions even
when plugged in at an angle, the two panel mounting flanges must have
sufficient electrical contact with the metal mounting panel.
Tightening torque of locking screw: 3 Nm.
Classifications
eCl@ss
eCl@ss 4.0
eCl@ss 4.1
eCl@ss 5.0
eCl@ss 5.1
eCl@ss 6.0
eCl@ss 7.0
eCl@ss 8.0
27140816
27140816
27371205
27371205
27371205
27371205
27371205
ETIM
ETIM 2.0
ETIM 3.0
ETIM 4.0
ETIM 5.0
EC000437
EC000437
EC000437
EC000437
2/4/14 Page 2 / 5
https://www.phoenixcontact.com/us/products/1690273
Housing - HC-B 16-TMS-100/O1STM40G-EUA - 1690273
Classifications
UNSPSC
UNSPSC 6.01
UNSPSC 7.0901
UNSPSC 11
UNSPSC 12.01
UNSPSC 13.2
31261502
31261502
31261502
31261502
31261502
Approvals
Approvals
Approvals
GOST
Ex Approvals
Approvals submitted
Approval details
GOST
Accessories
Accessories
Full screw connection
Cable gland - HC-K-KV-M40(19-28) - 1690655
Plastic screw connection up to 5 bar, thread length: 10 mm, cable diameter: 19 - 28 mm, WAF 46, screw connection:
M40
2/4/14 Page 3 / 5
https://www.phoenixcontact.com/us/products/1690273
Housing - HC-B 16-TMS-100/O1STM40G-EUA - 1690273
Accessories
Cable gland - HC-M-KV-M40(19-27) - 1690590
Metal screw connection up to 5 bar, thread length: 8 mm, cable diameter: 19 - 27 mm, WAF 43, screw connection: M40
Cable gland - HC-M-KV-M40(27-34) - 1607729
Metal screw connection up to 5 bar, thread length: 8 mm, cable diameter: 27 ... 34 mm, WAF 50, screw connection: M40
Panel mounting flange
Mounting flange - HC-B-AF - 1686533
Panel mounting flange for HEAVYCON-ADVANCE TMS housing with screw locking
Mounting flange - HC-B-AF-SET - 1604638
Panel mounting flange for screw locking, set comprising 2 panel mounting flanges with 4 self-tapping Torx® head screws
and 4 fan-type washers
Protective cover
Protective covers - HC-B 16-TMS-SD-IP50 - 1690752
HEAVYCON ADVANCE IP50 protective cover B16, for panel mounting side, with clip locking, with retaining cord,
diameter of retaining cord eyelet 3 mm
2/4/14 Page 4 / 5
https://www.phoenixcontact.com/us/products/1690273
Housing - HC-B 16-TMS-100/O1STM40G-EUA - 1690273
Accessories
Protective covers - HC-B 16-TMS-SD-IP65 - 1690794
HEAVYCON ADVANCE IP65 protective cover B16, for panel mounting side, with screw locking, with retaining cord,
diameter of retaining cord eyelet 3 mm
Drawings
Dimensioned drawing
103
86
Dimensioned drawing
126
57
32
35
Ø4,5
1)
Ø3,6
2)
2)
Panel cutout
When self-tapping screws are used (Torx® 20, M4)
© Phoenix Contact 2013 - all rights reserved
http://www.phoenixcontact.com
100