https://www.phoenixcontact.com/pi/products/1584347
Contact insert - HC-D 7-I-CT-F - 1584347
Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's
documentation. Our General Terms of Use for Downloads are valid
(http://phoenixcontact.com/download)
Contact insert, number of positions: 7+PE, size: D7, number of connections per position: 1, Socket, Crimp
connection, 250 V, 10 A, 0.14 mm² ... 2.5 mm², Only suitable for plastic housings
Your advantages
Can be used in rail vehicles, satisfy DIN EN 45545-2 with requirement sets R22, R23, and R24 in hazard levels HL1, HL2, and HL3.
Key Commercial Data
Packing unit
GTIN
GTIN
4046356142601
1 pc
Technical data
General
Note
Connection method
Number of connections per position
Degree of pollution
Overvoltage category
Number of positions
Insertion/withdrawal cycles
Size
Contact numbering
Conductor cross section
Connection cross section AWG
Stripping length of the individual wire
For HC-D7 housing, crimp contacts CK1,6-ED (crimp contacts not
included in scope of supply)
Crimp connection
1
3
III
7+PE
≥ 500
D7
1-7
0.14 mm² ... 2.5 mm²
26 ... 14
8 mm (0.14 ... 1.5 mm²)
6 mm (2.5 mm²)
Assembly instructions
To ensure correct use, installation in housing with IP54 protection or
better is required
11/11/2018 Page 1 / 4
https://www.phoenixcontact.com/pi/products/1584347
Contact insert - HC-D 7-I-CT-F - 1584347
Technical data
General
The contact insert may on be installed in plastic housings of the HC-
D07-STA...-PL-BK range.
Ambient conditions
Ambient temperature (operation)
-40 °C ... 125 °C (including heating up of contacts)
Material data
Seal material
Contact material
Contact surface material
Contact carrier material
Standards/regulations
NBR
Copper alloy
Ag (alternatively Au)
PC
PC: Fire protection in rail vehicles - requirement sets R22, R23, and R24
acc. to DIN EN 45545-2 (Risk level HL1 - HL3)
Electrical characteristics
Rated voltage (III/3)
Rated surge voltage
Rated current
250 V
4 kV
10 A
Standards and Regulations
Constructional and testing regulations
DIN VDE 0627/86
DIN VDE 0110/02.79
DIN VDE 0110-1/04.97
IEC 60664-1, DIN IEC 60512
IEC 60352
Flammability rating according to UL 94
V0
Environmental Product Compliance
REACh SVHC
China RoHS
Lead 7439-92-1
Environmentally Friendly Use Period = 50
For details about hazardous substances go to tab “Downloads”,
Category “Manufacturer's declaration”
Drawings
Schematic diagram
Current strength [A]
Diagram
20
16
12
8
4
= 1,5 mm
2
= 1,0 mm
2
= 0,75 mm
2
7
6
5
4
2
3
2
3
7
6
5
4
1
1
Connector pin assignment connection side: Left
pin; right socket
0
0
20
40
60
80
100
120
Ambient temperature [°C]
Derating diagram: Series HC-D 7-I-CT..
11/11/2018 Page 2 / 4
https://www.phoenixcontact.com/pi/products/1584347
Contact insert - HC-D 7-I-CT-F - 1584347
Dimensional drawing
32
21
Female insert
Approvals
Approvals
Approvals
CSA / GL / UL Recognized / EAC
Ex Approvals
Approval details
CSA
Nominal voltage UN
Nominal current IN
mm²/AWG/kcmil
http://www.csagroup.org/services-industries/product-listing/
600 V
10 A
14
21
13631
GL
http://exchange.dnv.com/tari/
6196614 HH
UL Recognized
Nominal voltage UN
Nominal current IN
mm²/AWG/kcmil
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm
600 V
12 A
14
FILE E 118976
11/11/2018 Page 3 / 4
https://www.phoenixcontact.com/pi/products/1584347
Contact insert - HC-D 7-I-CT-F - 1584347
Approvals
EAC
RU C-
DE.AI30.B.01102
Phoenix Contact 2018 © - all rights reserved
http://www.phoenixcontact.com
PHOENIX CONTACT GmbH & Co. KG
Flachsmarktstr. 8
32825 Blomberg
Germany
Tel. +49 5235 300