TITLE
Low Loss Microwave Coax,
24 AWG
PART No.
REV
10
PAGE
1 of 1
086SC-2401
Signal Conductor
Insulation
2.57+/-0.127mm
(0.101+/-0.005")
Inner Shield
Braid Shield
Jacket
CONSTRUCTION
Signal Conductor: 0.0201"+/-0.0002" (0.51+/-0.0051mm), Silver Plated Copper per ASTM B-298
Insulation: FEP per applicable paragraph MIL-DTL-17, 0.065"+/-0.001" (1.65+/-0.0256mm) OD
Inner Shield: Helically Overlapped Flat Silver Plated Copper per ASTM B-298
Braid Shield: 40 AWG Silver Plated Copper per ASTM B-298, >90% Coverage
Overall Shield Diameter: 0.085"+/-0.002 (2.18+/-0.05mm)
Jacket: FEP in accordance with MIL-DTL-17, Type IX
Wall Thickness: 0.008" (0.19mm)
Color: Blue
ELECTRICAL
Impedance: 50+/-1 ohms
Velocity Of Propagation: 70% Ref.
Capacitance: 29 pF/ft (95 pF/m) Ref.
GENERAL
Temperature Rating: -65C to 165C
Static Bend Radius: 0.3" (7.6mm)
Dynamic Bend Radius: 0.6" (15mm)
Weight: 13 lbs/1000ft
Freq
(GHz)
0.5
1
2
4
8
12
18
Attenuation
(dB/100 ft)
16
24
34
48
70
88
111
Avg Power
(W)
168
117
80
55
37
32
23
This document is the
property of TEMP-FLEX.
It may not be disclosed,
reproduced, or otherwise
used without permission.
Rev
9
9
DCR
3333
3429
Description
Braid Shield P/N Change.
Remove Patent # from General Notes.
App’d
KP
J Sanyal
Date
4/2/13
7/8/13
10
4036
Update Respool Requirements.
KP
9/25/14
Address: 26 Milford Road, South Grafton, MA 01560 Phone: (508)-839-5987 Fax: (508)-839-4128